ﻻ يوجد ملخص باللغة العربية
Resistive Plate Chambers (RPC) have shown stable operation at the Large Hadron Collider and satisfactory efficiency for the entire Run 1 (2010-2013) and Run 2 (2015-2018) with C$_{2}$H$_{2}$F$_{4}$-based gas mixtures and the addition of SF$_{6}$ and i-C$_{4}$H$_{10}$. Since its global warming potential (GWP) is high, C$_{2}$H$_{2}$F$_{4}$ is phasing out of production due to recent European Union regulations and as a result its cost is progressively increasing. Therefore, finding a new RPC gas mixture with a low GWP has become extremely important. This contribution describes the simulation of the RPC efficiency with tetrafluoropropene C$_{3}$H$_{2}$F$_{4}$ (HFO1234ze), a hydrofluoroolefin with very low GWP. Simulation results are systematically compared with measurements of RPC efficiency in C$_{3}$H$_{2}$F$_{4}$-based gas mixtures with the addition of different combinations of Ar, He, CO$_{2}$, O$_{2}$ and i-C$_{4}$H$_{10}$ in various concentrations. This simulation allows the study of the interplay between C$_{3}$H$_{2}$F$_{4}$ and the other gas components in the mixture as well as may allow the identification of the most promising environment-friendly gas mixtures with C$_{3}$H$_{2}$F$_{4}$ for RPCs.
The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo s
Gaseous detectors are widely used in high-energy physics experiments, and in particular at the CERN Large Hadron Collider (LHC), to provide tracking and triggering over large volumes. It has been recently estimated that Resistive Plate Chambers (RPC)
The muon identification system of the ALICE experiment at the CERN LHC is based on Resistive Plate Chamber (RPC) detectors. These RPCs are operated in the so-called maxi-avalanche mode with a gas mixture made of tetrafluoroethane (C$_{2}$H$_{2}$F$_{4
The DHCAL, the Digital Hadron Calorimeter, is a prototype calorimeter based on Resistive Plate Chambers (RPCs). The design emphasizes the imaging capabilities of the detector in an effort to optimize the calorimeter for the application of Particle Fl
In this paper we propose a new concept for streamer quenching in Resistive Plate Chambers (RPCs). In our approach, the multiplication process is quenched by the appropriate design of a mechanical structure inserted between the two resistive electrode