ترغب بنشر مسار تعليمي؟ اضغط هنا

A Multi-Modal Miniature Surface Forces Apparatus (uSFA) for Interfacial Science Measurements

46   0   0.0 ( 0 )
 نشر من قبل Kai Kristiansen
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Advances in the research of intermolecular and surface interactions result from the development of new and improved measurement techniques and combinations of existing techniques. Here, we present a new miniature version of the Surface Force Apparatus (the uSFA) that has been designed for ease of use and multi-modal capabilities with retention of the capabilities of other SFA models including accurate measurement of surface separation distance and physical characterization of dynamic and static physical forces (i.e., normal, shear, and friction) and interactions (e.g., van der Waals, electrostatic, hydrophobic, steric, biospecific). The small physical size of the uSFA, compared to previous SFA models, makes it portable and suitable for integration into commercially available optical and fluorescence light microscopes, as demonstrated here. The large optical path entry and exit ports make it ideal for concurrent force measurements and spectroscopy studies. Examples of the use of the uSFA in combination with surface plasmon resonance (SPR) and Raman spectroscopy measurements are presented. Due to the short working distance constraints associated with Raman spectroscopy, an interferometric technique was developed and applied for calculating the inter-surface separation distance based on Newtons rings. The introduction of the muSFA will mark a transition in SFA usage from primarily physical characterization to concurrent physical characterization with in situ chemical and biological characterization to study interfacial phenomena, including (but not limited to) molecular adsorption, fluid flow dynamics, determination of surface species and morphology, and (bio) molecular binding kinetics.



قيم البحث

اقرأ أيضاً

Modern interfacial science is increasingly multi-disciplinary. Unique insight into interfacial interactions requires new multimodal techniques for interrogating surfaces with simultaneous complementary physical and chemical measurements. We describe here the design and testing of a microscope that incorporates a miniature Surface Forces Apparatus ({mu}SFA) in sphere vs. flat mode for force-distance measurements, while simultaneously acquiring Raman spectra of the confined zone. The microscope uses a simple optical setup that isolates independent optical paths for (i) the illumination and imaging of Newtons Rings and (ii) Raman-mode excitation and efficient signal collection. We benchmark the methodology by examining Teflon thin films in asymmetric (Teflon-water-glass) and symmetric (Teflon-water-Teflon) configurations. Water is observed near the Teflon-glass interface with nanometer-scale sensitivity in both the distance and Raman signals. We perform chemically-resolved, label-free imaging of confined contact regions between Teflon and glass surfaces immersed in water. Remarkably, we estimate that the combined approach enables vibrational spectroscopy with single water monolayer sensitivity within minutes. Altogether, the Raman-{mu}SFA allows exploration of molecular confinement between surfaces with chemical selectivity and correlation with interaction forces.
A broad range of scientific and industrial disciplines require precise optical measurements at very low light levels. Single-photon detectors combining high efficiency and high time resolution are pivotal in such experiments. By using relatively thic k films of NbTiN (8-11,nm) and improving the pattern fidelity of the nano-structure of the superconducting nanowire single-photon detectors (SNSPD), we fabricated devices demonstrating superior performance over all previously reported detectors in the combination of efficiency and time resolution. Our findings prove that small variations in the nanowire width, in the order of a few nanometers, can lead to a significant penalty on their temporal response. Addressing these issues, we consistently achieved high time resolution (best device 7.7,ps, other devices $sim$10-16,ps) simultaneously with high system detection efficiencies ($80-90%$) in the wavelength range of 780-1000,nm, as well as in the telecom bands (1310-1550,nm). The use of thicker films allowed us to fabricate large-area multi-pixel devices with homogeneous pixel performance. We first fabricated and characterized a $100times100, mu m^2$ 16-pixel detector and showed there was little variation among individual pixels. Additionally, to showcase the power of our platform, we fabricated and characterized 4-pixel multimode fiber-coupled detectors and carried out photon correlation experiments on a nanowire quantum dot resulting in $g^2(0)$ values lower than 0.04. The multi-pixel detectors alleviate the need for beamsplitters and can be used for higher order correlations with promising prospects not only in the field of quantum optics, but also in bio-imaging applications, such as fluorescence microscopy and positron emission tomography.
37 - M. Heine , S. Courtin , G. Fruet 2018
The STELLA (STELlar LAboratory) experimental station for the measurement of deep sub-barrier light heavy-ion fusion cross sections has been installed at the Androm`{e}de accelerator at the Institut de Physique Nucl{e}aire, Orsay (France). The setup i s designed for the direct experimental determination of heavy-ion fusion cross sections as low as tens of picobarn. The detection concept is based on the coincident measurement of emitted gamma rays with the UK FATIMA (FAst TIMing Array) and evaporated charged particles using a silicon detector array. Key developments relevant to reaching the extreme sub-barrier fusion region are a rotating target mechanism to sustain beam intensities above 10$mu$A, an ultra-high vacuum to prevent carbon built-up and gamma charged-particle timing in the order of nanoseconds sufficient to separate proton and alpha particles.
The design and operation of apparatus for measurements of in-beam hyperfine interactions and nuclear excited-state $g$ factors is described. This apparatus enables a magnetic field of about 0.1 tesla to be applied to the target and the target tempera ture to be set between $sim 4$ K and room temperature. Design concepts are developed mainly in terms of transient-field $g$-factor measurements following Coulomb excitation by the implantation perturbed angular correlation (IMPAC) technique. The formalism for perturbed angular correlations is outlined and a figure of merit for optimizing these measurements is derived to inform design. Particle detection is based on the use of silicon photodiodes of rectangular shape. The particle-$gamma$ angular correlation formalism for this case is described. The experimental program to date includes temperature-dependent studies of hyperfine fields, transient-field $g$-factor measurements, and time-dependent perturbed angular distribution (TDPAD) studies.
We describe a modular apparatus for use in parity-violation measurements in epithermal neutron-nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr. Neutron Scattering Center at Los Alamos National Laboratory. This apparat us is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron-nucleus resonances in the 0.1-10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a (^3)He-$^{4}$He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency (^6)Li-(^{7})Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of $^{3}$He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in $^{139}$La which employs two identical $^{139}$La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا