ترغب بنشر مسار تعليمي؟ اضغط هنا

Spatio-temporal normalized cross-correlation for estimation of the displacement field in ultrasound elastography

88   0   0.0 ( 0 )
 نشر من قبل Morteza Mirzaei
 تاريخ النشر 2018
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper introduces a novel technique to estimate tissue displacement in quasi-static elastography. A major challenge in elastography is estimation of displacement (also referred to time-delay estimation) between pre-compressed and post-compressed ultrasound data. Maximizing normalized cross correlation (NCC) of ultrasound radio-frequency (RF) data of the pre- and post-compressed images is a popular technique for strain estimation due to its simplicity and computational efficiency. Several papers have been published to increase the accuracy and quality of displacement estimation based on NCC. All of these methods use spatial windows to estimate NCC, wherein displacement magnitude is assumed to be constant within each window. In this work, we extend this assumption along the temporal domain to exploit neighboring samples in both spatial and temporal directions. This is important since traditional and ultrafast ultrasound machines are, respectively, capable of imaging at more than 30 frame per second (fps) and 1000 fps. We call our method spatial temporal normalized cross correlation (STNCC) and show that it substantially outperforms NCC using simulation, phantom and in-vivo experiments.

قيم البحث

اقرأ أيضاً

Ultrasound elastography is an emerging noninvasive imaging technique wherein pathological alterations can be visualized by revealing the mechanical properties of the tissue. Estimating tissue displacement in all directions is required to accurately e stimate the mechanical properties. Despite capabilities of elastography techniques in estimating displacement in both axial and lateral directions, estimation of axial displacement is more accurate than lateral direction due to higher sampling frequency, higher resolution and having a carrier signal propagating in the axial direction. Among different ultrasound imaging techniques, Synthetic Aperture (SA) has better lateral resolution than others, but it is not commonly used for ultrasound elastography due to its limitation in imaging depth of field. Virtual source synthetic aperture (VSSA) imaging is a technique to implement synthetic aperture beamforming on the focused transmitted data to overcome limitation of SA in depth of field while maintaining the same lateral resolution as SA. Besides lateral resolution, VSSA has the capability of increasing sampling frequency in the lateral direction without interpolation. In this paper, we utilize VSSA to perform beamforming to enable higher resolution and sampling frequency in the lateral direction. The beamformed data is then processed using our recently published elastography technique, OVERWIND [1]. Simulation and experimental results show substantial improvement in estimation of lateral displacements.
In this paper, we propose Plane Wave Elastography (PWE), a novel ultrasound shear wave elastography (SWE) approach. Currently, commercial methods for SWE rely on directional filtering based on the prior knowledge of the wave propagation direction, to remove complicated wave patterns formed due to reflection and refraction. The result is a set of decomposed directional waves that are separately analyzed to construct shear modulus fields that are then combined through compounding. Instead, PWE relies on a rigorous representation of the wave propagation using the frequency-domain scalar wave equation to automatically select appropriate propagation directions and simultaneously reconstruct shear modulus fields. Specifically, assuming a homogeneous, isotropic, incompressible, linear-elastic medium, we represent the solution of the wave equation using a linear combination of plane waves propagating in arbitrary directions. Given this closed-form solution, we formulate the SWE problem as a nonlinear least-squares optimization problem which can be solved very efficiently. Through numerous phantom studies, we show that PWE can handle complicated waveforms without prior filtering and is competitive with state-of-the-art that requires prior filtering based on the knowledge of propagation directions.
Objective: Realistic tissue-mimicking phantoms are essential for the development, the investigation and the calibration of medical imaging techniques and protocols. Because it requires taking both mechanical and imaging properties into account, the d evelopment of robust, calibrated phantoms is a major challenge in elastography. Soft polyvinyl chloride gels in a liquid plasticizer (plastisol or PVCP) have been proposed as soft tissue-mimicking phantoms (TMP) for elasticity imaging. PVCP phantoms are relatively low-cost and can be easily stored over long time periods without any specific requirements. In this work, the preparation of a PVCP gel phantom for both MR and ultrasoundelastography is proposed and its acoustic, NMR and mechanical properties are studied.Material and methods: The acoustic and magnetic resonance imaging properties of PVCP are measured for different mass ratios between ultrasound speckle particles and PVCP solution, and between resin and plasticizer. The linear mechanical properties of plastisol samples are then investigated over time using not only indentation tests, but also MR and ultrasound-elastography clinical protocols. These properties are compared to typical values reported for biological soft tissues and to the values found in the literature for PVCP gels.Results and conclusions: After a period of two weeks, the mechanical properties of the plastisol samples measured with indentation testing are stable for at least the following 4 weeks (end of follow-up period 43 days after gelation-fusion). Neither the mechanical nor the NMR properties of plastisol gels were found to be affected by the addition of cellulose as acoustic speckle. Mechanical properties of the proposed gels were successfully characterized by clinical, commercially-available MR Elastography and sonoelastography protocols. PVCP with a mass ratio of ultrasound speckle particles of 0.6% to 0.8% and a mass ratio between resin and plasticizer between 50 and 70% appears as a good TMP candidate that can be used with both MR and ultrasound-based elastography methods.
94 - Tal I. Sommer , Ori Katz 2021
We present an adaptation of the pixel-reassignment technique from confocal fluorescent microscopy to coherent ultrasound imaging. The method, Ultrasound Pixel-Reassignment (UPR), provides a resolution and signal to noise (SNR) improvement in ultrasou nd imaging by computationally reassigning off-focus signals acquired using traditional plane-wave compounding ultrasonography. We theoretically analyze the analogy between the optical and ultrasound implementations of pixel reassignment, and experimentally evaluate the imaging quality on tissue-mimicking acoustic phantoms. We demonstrate that UPR provides a $25%$ resolution improvement and a $3dB$ SNR improvement in in-vitro scans, without any change in hardware or acquisition scheme.
In this paper, we consider the problem of estimating the internal displacement field of an object which is being subjected to a deformation, from Optical Coherence Tomography (OCT) images before and after compression. For the estimation of the intern al displacement field we propose a novel algorithm, which utilizes particular speckle information to enhance the quality of the motion estimation. We present numerical results based on both simulated and experimental data in order to demonstrate the usefulness of our approach, in particular when applied for quantitative elastography, when the material parameters are estimated in a second step based on the internal displacement field.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا