ترغب بنشر مسار تعليمي؟ اضغط هنا

Sensitive spin detection using an on-chip SQUID-waveguide resonator

72   0   0.0 ( 0 )
 نشر من قبل Irinel Chiorescu
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Precise detection of spin resonance is of paramount importance to achieve coherent spin control in quantum computing. We present a novel setup for spin resonance measurements, which uses a dc-SQUID flux detector coupled to an antenna from a coplanar waveguide. The SQUID and the waveguide are fabricated from 20~nm Nb thin film, allowing high magnetic field operation with the field applied parallel to the chip. We observe a resonance signal between the first and third excited states of Gd spins $S=7/2$ in a CaWO$_4$ crystal, relevant for state control in multi-level systems.


قيم البحث

اقرأ أيضاً

145 - Y. P. Pan , J. J. Zhu , Y. Feng 2021
Scanning superconducting quantum interference device microscopy (sSQUID) is currently one of the most effective methods for direct and sensitive magnetic flux imaging on the mesoscopic scale. A SQUID-on-chip design allows integration of field coils f or susceptometry in a gradiometer setup which is very desirable for measuring magnetic responses of quantum matter. However, the spatial resolution of such a design has largely been limited to micrometers due to the difficulty in approaching the sample. Here, we used electron beam lithography technology in the fabrication of the 3D nano-bridge-based SQUID devices to prepare pick-up coils with diameters down to 150 nm. Furthermore, we integrated the deep silicon etching process in order to minimize the distance between the pick-up coil and the wafer edge. Combined with a tuning-fork-based scanning head, the sharpness of the etched chip edge enables a precision of 5 nm in height control. By scanning measurements on niobium chessboard samples using these improved SQUID devices, we demonstrate sub-micron spatial resolutions in both magnetometry and susceptometry, significantly better than our previous generations of nano-SQUIDs. Such improvement in spatial resolution of SQUID-on-chip is a valuable progress for magnetic imaging of quantum materials and devices in various modes.
114 - T. Frey , P. J. Leek , M. Beck 2012
We present microwave frequency measurements of the dynamic admittance of a quantum dot tunnel coupled to a two-dimensional electron gas. The measurements are made via a high-quality 6.75 GHz on-chip resonator capacitively coupled to the dot. The reso nator frequency is found to shift both down and up close to conductance resonance of the dot corresponding to a change of sign of the reactance of the system from capacitive to inductive. The observations are consistent with a scattering matrix model. The sign of the reactance depends on the detuning of the dot from conductance resonance and on the magnitude of the tunnel rate to the lead with respect to the resonator frequency. Inductive response is observed on a conductance resonance, when tunnel coupling and temperature are sufficiently small compared to the resonator frequency.
We report a low temperature measurement technique and magnetization data of a quantum molecular spin, by implementing an on-chip SQUID technique. This technique enables the SQUID magnetometery in high magnetic fields, up to 7 Tesla. The main challeng es and the calibration process are detailed. The measurement protocol is used to observe quantum tunneling jumps of the S=10 molecular magnet, Mn12-tBuAc. The effect of transverse field on the tunneling splitting for this molecular system is addressed as well.
Although the detection of light at terahertz (THz) frequencies is important for a large range of applications, current detectors typically have several disadvantages in terms of sensitivity, speed, operating temperature, and spectral range. Here, we use graphene as a photoactive material to overcome all of these limitations in one device. We introduce a novel detector for terahertz radiation that exploits the photothermoelectric (PTE) effect, based on a design that employs a dual-gated, dipolar antenna with a gap of 100 nm. This narrow-gap antenna simultaneously creates a pn junction in a graphene channel located above the antenna and strongly concentrates the incoming radiation at this pn junction, where the photoresponse is created. We demonstrate that this novel detector has an excellent sensitivity, with a noise-equivalent power of 80 pW-per-square-root-Hz at room temperature, a response time below 30 ns (setup-limited), a high dynamic range (linear power dependence over more than 3 orders of magnitude) and broadband operation (measured range 1.8-4.2 THz, antenna-limited), which fulfills a combination that is currently missing in the state-of-the-art detectors. Importantly, on the basis of the agreement we obtained between experiment, analytical model, and numerical simulations, we have reached a solid understanding of how the PTE effect gives rise to a THz-induced photoresponse, which is very valuable for further detector optimization.
We demonstrate electron spin polarization detection and electron paramagnetic resonance (EPR) spectroscopy using a direct current superconducting quantum interference device (dc-SQUID) magnetometer. Our target electron spin ensemble is directly glued on the dc-SQUID magnetometer that detects electron spin polarization induced by a external magnetic field or EPR in micrometer-sized area. The minimum distinguishable number of polarized spins and sensing volume of the electron spin polarization detection and the EPR spectroscopy are estimated to be $sim$$10^6$ and $sim$$10^{-10}$ $mathrm{cm}^{3}$ ($sim$0.1 pl), respectively.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا