ترغب بنشر مسار تعليمي؟ اضغط هنا

Low dose and fast grating-based x-ray phase-contrast imaging using the integrating-bucket phase modulation technique

160   0   0.0 ( 0 )
 نشر من قبل Shenghao Wang
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

X-ray phase-contrast imaging has experienced rapid development over the last few decades, and in this technology, the phase modulation strategy of phase-stepping is used most widely to measure the samples phase signal. However, because of its discontinuous nature, phase-stepping has the defects of worse mechanical stability and high exposure dose, which greatly hinder its wide application in dynamic phase measurement and potential clinical applications. In this manuscript, we demonstrate preliminary research on the use of integrating-bucket phase modulation method to retrieve the phase information in grating-based X-ray phase-contrast imaging. Experimental results showed that our proposed method can be well employed to extract the differential phase-contrast image, compared with the current mostly used phase-stepping strategy, advantage of integrating-bucket phase modulation technique is that fast measurement and low dose are promising.

قيم البحث

اقرأ أيضاً

100 - Shenghao Wang , Can Zhang 2017
We reported the usage of grating-based X-ray phase-contrast imaging in nondestructive testing of grating imperfections. It was found that electroplating flaws could be easily detected by conventional absorption signal, and in particular, we observed that the grating defects resulting from uneven ultraviolet exposure could be clearly discriminated with phase-contrast signal. The experimental results demonstrate that grating-based X-ray phase-contrast imaging, with a conventional low-brilliance X-ray source, a large field of view and a reasonable compact setup, which simultaneously yields phase- and attenuation-contrast signal of the sample, can be ready-to-use in fast nondestructive testing of various imperfections in gratings and other similar photoetching products.
Phase-contrast X-ray imaging can improve the visibility of weakly absorbing objects (e.g. soft tissues) by an order of magnitude or more compared to conventional radiographs. Previously, it has been shown that combining phase retrieval with computed tomography (CT) can increase the signal-to-noise ratio (SNR) by up to two orders of magnitude over conventional CT at the same radiation dose, without loss of image quality. Our experiments reveal that as radiation dose decreases, the relative improvement in SNR increases. We discovered this enhancement can be traded for a reduction in dose greater than the square of the gain in SNR. Upon reducing the dose 300 fold, the phase-retrieved SNR was still almost 10 times larger than the absorption contrast data. This reveals the potential for dose reduction factors in the tens of thousands without loss in image quality, which would have a profound impact on medical and industrial imaging applications.
Currently, dual-energy X-ray phase contrast imaging is usually conducted with an X-ray Talbot-Lau interferometer. However, in this system, the two adopted energy spectra have to be chosen carefully in order to match well with the phase grating. For e xample, the accelerating voltages of the X-ray tube are supposed to be respectively set as 40 kV and 70 kV, with other energy spectra being practically unusable for dual energy imaging. This system thus has low flexibility and maneuverability in practical applications. In this work, dual energy X-ray phase-contrast imaging is performed in a grating-based non-interferometric imaging system rather than in a Talbot-Lau interferometer. The advantage of this system is that, theoretically speaking, any two separated energy spectra can be utilized to perform dual energy X-ray phase-contrast imaging. The preliminary experimental results show that dual-energy X-ray phase contrast imaging is successfully performed when the accelerating voltages of the X-ray tube are successively set as 40 kV and 50 kV. Our work increases the flexibility and maneuverability when employing dual-energy X-ray phase-contrast imaging in medical diagnoses and nondestructive tests.
Two-dimensional Talbot array illuminators (TAIs) were designed, fabricated, and evaluated for high-resolution high-contrast x-ray phase imaging of soft tissue at 10-20keV. The TAIs create intensity modulations with a high compression ratio on the mic rometer scale at short propagation distances. Their performance was compared with various other wavefront markers in terms of period, visibility, flux efficiency and flexibility to be adapted for limited beam coherence and detector resolution. Differential x-ray phase contrast and dark-field imaging were demonstrated with a one-dimensional, linear phase stepping approach yielding two-dimensional phase sensitivity using Unified Modulated Pattern Analysis (UMPA) for phase retrieval. The method was employed for x-ray phase computed tomography reaching a resolution of 3$mu$m on an unstained murine artery. It opens new possibilities for three-dimensional, non-destructive, and quantitative imaging of soft matter such as virtual histology. The phase modulators can also be used for various other x-ray applications such as dynamic phase imaging, super-resolution structured illumination microscopy, or wavefront sensing.
Development of x-ray phase contrast imaging applications with a laboratory scale source have been limited by the long exposure time needed to obtain one image. We demonstrate, using the Betatron x-ray radiation produced when electrons are accelerated and wiggled in the laser-wakefield cavity, that a high quality phase contrast image of a complex object (here, a bee), located in air, can be obtained with a single laser shot. The Betatron x-ray source used in this proof of principle experiment has a source diameter of 1.7 microns and produces a synchrotron spectrum with critical energy E_c=12.3 +- 2.5 keV and 10^9 photons per shot in the whole spectrum.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا