POLAR is a new satellite-born detector aiming to measure the polarization of an unprecedented number of Gamma-Ray Bursts in the 50-500 keV energy range. The instrument, launched on-board the Tiangong-2 Chinese Space lab on the 15th of September 2016, is designed to measure the polarization of the hard X-ray flux by measuring the distribution of the azimuthal scattering angles of the incoming photons. A detailed understanding of the polarimeter and specifically of the systematic effects induced by the instruments non-uniformity are required for this purpose. In order to study the instruments response to polarization, POLAR underwent a beam test at the European Synchrotron Radiation Facility in France. In this paper both the beam test and the instrument performance will be described. This is followed by an overview of the Monte Carlo simulation tools developed for the instrument. Finally a comparison of the measured and simulated instrument performance will be provided and the instrument response to polarization will be presented.

قيم البحث

اقرأ أيضاً

The high performance requirements at the European Spallation Source have been driving the technological advances on the neutron detector front. Now more than ever is it important to optimize the design of detectors and instruments, to fully exploit t he ESS source brilliance. Most of the simulation tools the neutron scattering community has at their disposal target the instrument optimization until the sample position, with little focus on detectors. The ESS Detector Group has extended the capabilities of existing detector simulation tools to bridge this gap. An extensive software framework has been developed, enabling efficient and collaborative developments of required simulations and analyses -- based on the use of the Geant4 Monte Carlo toolkit, but with extended physics capabilities where relevant (like for Bragg diffraction of thermal neutrons in crystals). Furthermore, the MCPL (Monte Carlo Particle Lists) particle data exchange file format, currently supported for the primary Monte Carlo tools of the community (McStas, Geant4 and MCNP), facilitates the integration of detector simulations with existing simulations of instruments using these software packages. These means offer a powerful set of tools to tailor the detector and instrument design to the instrument application.
The Cherenkov Telescope Array (CTA) is a future gamma-ray observatory that is planned to significantly improve upon the sensitivity and precision of the current generation of Cherenkov telescopes. The observatory will consist of several dozens of tel escopes with different sizes and equipped with different types of cameras. Of these, the FlashCam camera system is the first to implement a fully digital signal processing chain which allows for a traceable, configurable trigger scheme and flexible signal reconstruction. As of autumn 2016, a prototype FlashCam camera for the medium-sized telescopes of CTA nears completion. First results of the ongoing system tests demonstrate that the signal chain and the readout system surpass CTA requirements. The stability of the system is shown using long-term temperature cycling.
The underground muon detector of the Pierre Auger Observatory is aimed at attaining direct measurements of the muonic component of extensive air showers produced by cosmic rays with energy from $10^{16.5}$ eV up to the region of the ankle (around $10 ^{18.7}$ eV). It consists of two nested triangular grids of underground scintillators with 433 m, and 750 m spacings and a total of 71 positions, each with 192 scintillator strips (30 m$^2$) deployed 2.3 m underground. The light produced by impinging muons in the scintillators is propagated with optical fibers towards an array of silicon photomultipliers. In this work, we present the development, validation, and performance of an end-to-end tool for simulating the response of the underground muon detector to single-muon signals, which constitutes the basis for further simulations of the whole array. Laboratory data and simulation outcomes are found consistent, showing that with the underground muon detector we can measure single muons, with an efficiency of 99 %, up to about 1050 particles arriving at exactly the same time in 30 m$^2$ of scintillator.
73 - G. Angloher , P. Bauer , A. Bento 2017
Scintillating, cryogenic bolometers are widely used in the field of rare event searches. Their main advantages are an excellent energy resolution and particle identification on an event-by-event basis. The sensitivity of experiments applying this det ector technique can be limited by the performance of the light channel and the presence of external backgrounds in the region of interest. In the framework of the CRESST-II experiment, we developed and successfully tested a novel detector design addressing both challenges. Using a large scale ($approx$unit[60]{cm$^2$}), beaker-shaped silicon light absorber, the signal height recorded in the light channel is improved by a factor 2.5 compared to conventional CRESTT-II detector modules. In combination with a large carrier crystal, a true $4pi$ veto system is established which allows to tag external background sources.
124 - G. Sottile , F. Russo , G. Agnetta 2013
UVSiPM is a light detector designed to measure the intensity of electromagnetic radiation in the 320-900 nm wavelength range. It has been developed in the framework of the ASTRI project whose main goal is the design and construction of an end-to-end Small Size class Telescope prototype for the Cherenkov Telescope Array. The UVSiPM instrument is composed by a multipixel Silicon Photo-Multiplier detector unit coupled to an electronic chain working in single photon counting mode with 10 nanosecond double pulse resolution, and by a disk emulator interface card for computer connection. The detector unit of UVSiPM is of the same kind as the ones forming the camera at the focal plane of the ASTRI prototype. Eventually, the UVSiPM instrument can be equipped with a collimator to regulate its angular aperture. UVSiPM, with its peculiar characteristics, will permit to perform several measurements both in lab and on field, allowing the absolute calibration of the ASTRI prototype.