ترغب بنشر مسار تعليمي؟ اضغط هنا

Large Area X-ray Proportional Counter (LAXPC) Instrument on AstroSat and Some Preliminary Results from its performance in the orbit

68   0   0.0 ( 0 )
 نشر من قبل J. S. Yadav Prof
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Large Area X-ray Propositional Counter (LAXPC) instrument on AstroSat is aimed at providing high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. To achieve large collecting area, a cluster of three co-aligned identical LAXPC detectors, is used to realize an effective area in access of about 6000 cm2 at 15 keV. The large detection volume of the LAXPC detectors, filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. In this article, we present salient features of the LAXPC detectors, their testing and characterization in the laboratory prior to launch and calibration in the orbit. Some preliminary results on timing and spectral characteristics of a few X-ray binaries and other type of sources, are briefly discussed to demonstrate that the LAXPC instrument is performing as planned in the orbit.

قيم البحث

اقرأ أيضاً

Large Area X-ray Proportional Counter (LAXPC) is one of the major AstroSat payloads. LAXPC instrument will provide high time resolution X-ray observations in 3 to 80 keV energy band with moderate energy resolution. A cluster of three co-aligned ident ical LAXPC detectors is used in AstroSat to provide large collection area of more than 6000 cm2 . The large detection volume (15 cm depth) filled with xenon gas at about 2 atmosphere pressure, results in detection efficiency greater than 50%, above 30 keV. With its broad energy range and fine time resolution (10 microsecond), LAXPC instrument is well suited for timing and spectral studies of a wide variety of known and transient X-ray sources in the sky. We have done extensive calibration of all LAXPC detectors using radioactive sources as well as GEANT4 simulation of LAXPC detectors. We describe in brief some of the results obtained during the payload verification phase along with LXAPC capabilities.
ASTROSAT is Indias first satellite fully devoted to astronomical observations covering a wide spectral band from optical to hard X-rays by a complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of the instruments is Large Area X-ray Proportional Counter with 3 identical detectors. In order to assess the performance of this instrument, a balloon experiment with two prototype Large Area X-ray Proportional Counters (LAXPC) was carried out on 2008 April 14. The design of these LAXPCs was similar to those on the ASTROSAT except that their field of view (FOV) was 3$^{circ}$ $times$ 3$^{circ}$ versus FOV of 1$^{circ}$ $times$ 1$^{circ}$ for the LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC, associated electronics and support systems were mounted on an oriented platform which could be pre-programmed to track any source in the sky. A brief description of the LAXPC design, laboratory tests, calibration and the detector characteristics is presented here. The details of the experiment and background counting rates of the 2 LAXPCs at the float altitude of about 41 km are presented in different energy bands. The bright black hole X-ray binary Cygnus X-1 (Cyg X-1) was observed in the experiment for $sim$ 3 hours. Details of Cyg X-1 observations, count rates measured from it in different energy intervals and the intensity variations of Cyg X-1 detected during the observations are presented and briefly discussed.
With its large effective area at hard X-rays, high time resolution and having co-aligned other instruments, AstroSat/LAXPC was designed to usher in a new era in rapid variability studies and wide spectral band measurements of the X-ray binaries. Over the last five years, the instrument has successfully achieved to a significant extent these Science goals. In the coming years, it is poised to make more important discoveries. This paper highlights the primary achievements of AstroSat/LAXPC in unraveling the behavior of black hole and neutron star systems and discusses the exciting possibility of the instruments contribution to future science.
Cadmium-Zinc-Telluride Imager (CZTI) is one of the five payloads on-board recently launched Indian astronomy satellite AstroSat. CZTI is primarily designed for simultaneous hard X-ray imaging and spectroscopy of celestial X-ray sources. It employs th e technique of coded mask imaging for measuring spectra in the energy range of 20 - 150 keV. It was the first scientific payload of AstroSat to be switched on after one week of the launch and was made operational during the subsequent week. Here we present preliminary results from the performance verification phase observations and discuss the in-orbit performance of CZTI.
We present the in-orbit performance and the first results from the ultra-violet Imaging telescope (UVIT) on ASTROSAT. UVIT consists of two identical 38cm coaligned telescopes, one for the FUV channel (130-180nm) and the other for the NUV (200-300nm) and VIS (320-550nm) channels, with a field of view of 28 $arcmin$. The FUV and the NUV detectors are operated in the high gain photon counting mode whereas the VIS detector is operated in the low gain integration mode. The FUV and NUV channels have filters and gratings, whereas the VIS channel has filters. The ASTROSAT was launched on 28th September 2015. The performance verification of UVIT was carried out after the opening of the UVIT doors on 30th November 2015, till the end of March 2016 within the allotted time of 50 days for calibration. All the on-board systems were found to be working satisfactorily. During the PV phase, the UVIT observed several calibration sources to characterise the instrument and a few objects to demonstrate the capability of the UVIT. The resolution of the UVIT was found to be about 1.4 - 1.7 $arcsec$ in the FUV and NUV. The sensitivity in various filters were calibrated using standard stars (white dwarfs), to estimate the zero-point magnitudes as well as the flux conversion factor. The gratings were also calibrated to estimate their resolution as well as effective area. The sensitivity of the filters were found to be reduced up to 15% with respect to the ground calibrations. The sensitivity variation is monitored on a monthly basis. UVIT is all set to roll out science results with its imaging capability with good resolution and large field of view, capability to sample the UV spectral region using different filters and capability to perform variability studies in the UV.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا