ترغب بنشر مسار تعليمي؟ اضغط هنا

Update On The Code Intercomparison and Benchmark For Muon Fluence and Absorbed Dose Induced By An 18-GeV Electron Beam After Massive Iron Shielding

95   0   0.0 ( 0 )
 نشر من قبل Mokhov, Nikolai
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In 1974, Nelson, Kase and Svensson published an experimental investigation on muon shielding around SLAC high-energy electron accelerators. They measured muon fluence and absorbed dose induced by 14 and 18 GeV electron beams hitting a copper/water beamdump and attenuated in a thick steel shielding. In their paper, they compared the results with the theoretical models available at that time. In order to compare their experimental results with present model calculations, we use the modern transport Monte Carlo codes MARS15, FLUKA2011 and GEANT4 to model the experimental setup and run simulations. The results are then compared between the codes, and with the SLAC data.



قيم البحث

اقرأ أيضاً

In 1974, Nelson, Kase, and Svenson published an experimental investigation on muon shielding using the SLAC high energy LINAC. They measured muon fluence and absorbed dose induced by a 18 GeV electron beam hitting a copper/water beam dump and attenua ted in a thick steel shielding. In their paper, they compared the results with the theoretical mode ls available at the time. In order to compare their experimental results with present model calculations, we use the modern transport Monte Carlo codes MARS15, FLUKA2011 and GEANT4 to model the experimental setup and run simulations. The results will then be compared between the codes, and with the SLAC data.
425 - Khaled Alharbi 2021
In the future the International Linear Collider (ILC), a helical undulator-based polarized positron source, is expected to be chosen. A high energy electron beam passes through a superconducting helical undulator in order to create circularly polariz ed photons which will be directed to a conversion target, resulting in electron-positron pairs. The resulting positron beam is longitudinally polarized. Since the photons are produced with an opening angle and pass through a long superconducting helical undulator, some of these photons will strike the undulator walls. Therefore photon masks must be placed along the undulator line in order to keep the power deposited in the undulator walls below the acceptable limit of 1W/m. The baseline design of the ILC is focused on 250 GeV center-of-mass energy and upgrade to center-of-mass energies of 350 and 500 GeV is foreseen. This paper shows a detailed study of the ideal power deposited along the masks for both 350 and 500 GeV center-of-mass energies.
The aim of this study was to investigate the impact of decay data provided by the newly developed stochastic atomic relaxation model BrIccEmis on dose point kernels (DPKs - radial dose distribution around a unit point source) and S-values (absorbed d ose per unit cumulated activity) of 14 Auger electron (AE) emitting radionuclides, namely 67Ga, 80mBr, 89Zr, 90Nb, 99mTc, 111In, 117mSn, 119Sb, 123I, 124I, 125I, 135La, 195mPt and 201Tl. Radiation spectra were based on the nuclear decay data from the medical internal radiation dose (MIRD) RADTABS program and the BrIccEmis code, assuming both an isolated-atom and condensed-phase approach. DPKs were simulated with the PENELOPE Monte Carlo (MC) code using event-by-event electron and photon transport. S-values for concentric spherical cells of various sizes were derived from these DPKS using appropriate geometric reduction factors. The number of Auger and Coster-Kronig (CK) electrons and x-ray photons released per nuclear decay (yield) from MIRD-RADTABS were consistently higher than those calculated using BrIccEmis. DPKs for the electron spectra from BrIccEmis were considerably different from MIRD-RADTABS in the first few hundred nanometres from a point source where most of the Auger electrons are stopped. S-values were, however, not significantly impacted as the differences in DPKS in the sub-micrometre dimension were quickly diminished in larger dimensions. Overestimation in the total AE energy output by MIRD-RADTABS leads to higher predicted energy deposition by AE emitting radionuclides, especially in the immediate vicinity of the decaying radionuclides. This should be taken into account when MIRD-RADTABS data are used to simulate biological damage at nanoscale dimensions.
132 - William Parke , Dalong Pang 2021
Therapeutic protons acting on O18-substituted thymidine increase cytotoxicity in radio-resistant human cancer cells. We consider here the physics behind the irradiation during proton beam therapy and diagnosis using O18-enriched thymine in DNA, with attention to the effect of the presence of thymine-18 on cancer cell death.
53 - M. Passera 2007
Recent Standard Model predictions for the anomalous magnetic moments of the electron, muon and tau lepton are reviewed and compared to the latest experimental values.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها