ترغب بنشر مسار تعليمي؟ اضغط هنا

Polarization leakage in epoch of reionization windows: II. Primary beam model and direction dependent calibration

130   0   0.0 ( 0 )
 نشر من قبل Khan Muhammad Bin Asad
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Leakage of diffuse polarized emission into Stokes I caused by the polarized primary beam of the instrument might mimic the spectral structure of the 21-cm signal coming from the epoch of reionization (EoR) making their separation difficult. Therefore, understanding polarimetric performance of the antenna is crucial for a successful detection of the EoR signal. Here, we have calculated the accuracy of the nominal model beam of LOFAR in predicting the leakage from Stokes I to Q, U by comparing them with the corresponding leakage of compact sources actually observed in the 3C295 field. We have found that the model beam has errors of less than or equal to 10% on the predicted levels of leakage of ~1% within the field of view, i. e. if the leakage is taken out perfectly using this model the leakage will reduce to $10^{-3}$ of the Stokes I flux. If similar levels of accuracy can be obtained in removing leakage from Stokes Q, U to I, we can say, based on the results of our previous paper, that the removal of this leakage using this beam model would ensure that the leakage is well below the expected EoR signal in almost the whole instrumental k-space of the cylindrical power spectrum. We have also shown here that direction dependent calibration can remove instrumentally polarized compact sources, given an unpolarized sky model, very close to the local noise level.

قيم البحث

اقرأ أيضاً

62 - K. M. B. Asad (1 , 2 , 3 2017
Leakage of polarized Galactic diffuse emission into total intensity can potentially mimic the 21-cm signal coming from the epoch of reionization (EoR), as both of them might have fluctuating spectral structure. Although we are sensitive to the EoR si gnal only in small fields of view, chromatic sidelobes from further away can contaminate the inner region. Here, we explore the effects of leakage into the EoR window of the cylindrically averaged power spectra (PS) within wide fields of view using both observation and simulation of the 3C196 and NCP fields, two observing fields of the LOFAR-EoR project. We present the polarization PS of two one-night observations of the two fields and find that the NCP field has higher fluctuations along frequency, and consequently exhibits more power at high-$k_parallel$ that could potentially leak to Stokes $I$. Subsequently, we simulate LOFAR observations of Galactic diffuse polarized emission based on a model to assess what fraction of polarized power leaks into Stokes $I$ because of the primary beam. We find that the rms fractional leakage over the instrumental $k$-space is $0.35%$ in the 3C196 field and $0.27%$ in the NCP field, and it does not change significantly within the diameters of $15^circ$, $9^circ$ and $4^circ$. Based on the observed PS and simulated fractional leakage, we show that a similar level of leakage into Stokes $I$ is expected in the 3C196 and NCP fields, and the leakage can be considered to be a bias in the PS.
Detection of the 21-cm signal coming from the epoch of reionization (EoR) is challenging especially because, even after removing the foregrounds, the residual Stokes $I$ maps contain leakage from polarized emission that can mimic the signal. Here, we discuss the instrumental polarization of LOFAR and present realistic simulations of the leakages between Stokes parameters. From the LOFAR observations of polarized emission in the 3C196 field, we have quantified the level of polarization leakage caused by the nominal model beam of LOFAR, and compared it with the EoR signal using power spectrum analysis. We found that at 134--166 MHz, within the central 4$^circ$ of the field the $(Q,U)rightarrow I$ leakage power is lower than the EoR signal at $k<0.3$ Mpc$^{-1}$. The leakage was found to be localized around a Faraday depth of 0, and the rms of the leakage as a fraction of the rms of the polarized emission was shown to vary between 0.2-0.3%, both of which could be utilized in the removal of leakage. Moreover, we could define an `EoR window in terms of the polarization leakage in the cylindrical power spectrum above the PSF-induced wedge and below $k_parallelsim 0.5$ Mpc$^{-1}$, and the window extended up to $k_parallelsim 1$ Mpc$^{-1}$ at all $k_perp$ when 70% of the leakage had been removed. These LOFAR results show that even a modest polarimetric calibration over a field of view of $lesssim 4^circ$ in the future arrays like SKA will ensure that the polarization leakage remains well below the expected EoR signal at the scales of 0.02-1 Mpc$^{-1}$.
This is the third installment in a series of papers in which we investigate calibration artefacts. Calibration artefacts (also known as ghosts or spurious sources) are created when we calibrate with an incomplete model. In the first two papers of thi s series we developed a mathematical framework which enabled us to study the ghosting mechanism itself. An interesting concomitant of the second paper was that ghosts appear in symmetrical pairs. This could possibly account for spurious symmetrization. Spurious symmetrization refers to the appearance of a spurious source (the anti-ghost) symmetrically opposite an unmodelled source around a modelled source. The analysis in the first two papers indicates that the anti-ghost is usually very faint, in particular when a large number of antennas are used. This suggests that spurious symmetrization will mainly occur at an almost undetectable flux level. In this paper, we show that phase-only calibration produces an anti-ghost that is $N$-times (where $N$ denotes the number of antennas in the array) as bright as the one produced by phase and amplitude calibration and that this already bright ghost can be further amplified by the primary beam correction.
The process of wide-field synthesis imaging is explored, with the aim of understanding the implications of variable, polarised primary beams for forthcoming Epoch of Reionisation experiments. These experiments seek to detect weak signatures from reds hifted 21cm emission in deep residual datasets, after suppression and subtraction of foreground emission. Many subtraction algorithms benefit from low side-lobes and polarisation leakage at the outset, and both of these are intimately linked to how the polarised primary beams are handled. Building on previous contributions from a number of authors, in which direction-dependent corrections are incorporated into visibility gridding kernels, we consider the special characteristics of arrays of fixed dipole antennas operating around 100-200 MHz, looking towards instruments such as the Square Kilometre Array (SKA) and the Hydrogen Epoch of Reionization Arrays (HERA). We show that integrating snapshots in the image domain can help to produce compact gridding kernels, and also reduce the need to make complicated polarised leakage corrections during gridding. We also investigate an alternative form for the gridding kernel that can suppress variations in the direction-dependent weighting of gridded visibilities by 10s of dB, while maintaining compact support.
In 21 cm cosmology, precision calibration is key to the separation of the neutral hydrogen signal from very bright but spectrally-smooth astrophysical foregrounds. The Hydrogen Epoch of Reionization Array (HERA), an interferometer specialized for 21 cm cosmology and now under construction in South Africa, was designed to be largely calibrated using the self-consistency of repeated measurements of the same interferometric modes. This technique, known as redundant-baseline calibration resolves most of the internal degrees of freedom in the calibration problem. It assumes, however, on antenna elements with identical primary beams placed precisely on a redundant grid. In this work, we review the detailed implementation of the algorithms enabling redundant-baseline calibration and report results with HERA data. We quantify the effects of real-world non-redundancy and how they compare to the idealized scenario in which redundant measurements differ only in their noise realizations. Finally, we study how non-redundancy can produce spurious temporal structure in our calibration solutions--both in data and in simulations--and present strategies for mitigating that structure.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا