ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurement of the branching ratio of $bar{B} to D^{(ast)} tau^- bar{ u}_tau$ relative to $bar{B} to D^{(ast)} ell^- bar{ u}_ell$ decays with hadronic tagging at Belle

224   0   0.0 ( 0 )
 نشر من قبل Thomas Kuhr
 تاريخ النشر 2015
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

We report a measurement of the branching fraction ratios R(D(*)) of Bbar -> D(*) tau- nubar_tau relative to Bbar -> D()* l- nubar_l (where l = e or mu) using the full Belle data sample of 772 x 10^6 BBbar pairs collected at the Y(4S) resonance with the Belle detector at the KEKB asymmetric-energy e+e- collider. The measured values are R(D)= 0.375 +- 0.064(stat.) +- 0.026(syst.) and R(D*) = 0.293 +- 0.038(stat.) +- 0.015(syst.). The analysis uses hadronic reconstruction of the tag-side B meson and purely leptonic tau decays. The results are consistent with earlier measurements and do not show a significant deviation from the standard model prediction.



قيم البحث

اقرأ أيضاً

We report a measurement of ratio ${cal R}(D^*) = {cal B}(bar{B}^0 rightarrow D^{*+} tau^- bar{ u}_{tau})/{cal B}(bar{B}^0 rightarrow D^{*+} ell^- bar{ u}_{ell})$, where $ell$ denotes an electron or a muon. The results are based on a data sample conta ining $772times10^6$ $Bbar{B}$ pairs recorded at the $Upsilon(4S)$ resonance with the Belle detector at the KEKB $e^+ e^-$ collider. We select a sample of $B^0 bar{B}^0$ pairs by reconstructing both $B$ mesons in semileptonic decays to $D^{*mp} ell^{pm}$. We measure ${cal R}(D^*)= 0.302 pm 0.030({rm stat)} pm 0.011({rm syst)}$, which is within $1.6 sigma$ of the Standard Model theoretical expectation, where $sigma$ is the standard deviation including systematic uncertainties.
375 - Y. Sato , T. Iijima , K. Adamczyk 2016
We report a measurement of the ratio ${cal R}(D^*) = {cal B}(bar{B}^0 rightarrow D^{*+} tau^- bar{ u}_{tau})/{cal B}(bar{B}^0 rightarrow D^{*+} ell^- bar{ u}_{ell})$, where $ell$ denotes an electron or a muon. The results are based on a data sample c ontaining $772times10^6$ $Bbar{B}$ pairs recorded at the $Upsilon(4S)$ resonance with the Belle detector at the KEKB $e^+ e^-$ collider. We select a sample of $B^0 bar{B}^0$ pairs by reconstructing both $B$ mesons in semileptonic decays to $D^{*mp} ell^{pm}$. We measure ${cal R}(D^*)= 0.302 pm 0.030({rm stat)} pm 0.011({rm syst)}$, which is within $1.6 sigma$ of the Standard Model theoretical expectation, where the standard deviation $sigma$ includes systematic uncertainties. We use this measurement to constrain several scenarios of new physics in a model-independent approach.
We evaluate long-distance electromagnetic (QED) contributions to $bar{B}{}^0 to D^+ tau^{-} bar{ u}_{tau}$ and $B^- to D^0 tau^{-} bar{ u}_{tau}$ relative to $bar{B}{}^0 to D^+ mu^{-} bar{ u}_{mu}$ and $B^- to D^0 mu^{-} bar{ u}_{mu}$, respectively, in the standard model. We point out that the QED corrections to the ratios $R(D^{+})$ and $R(D^{0})$ are not negligible, contrary to the expectation that radiative corrections are almost canceled out in the ratio of the two branching fractions. The reason is that long-distance QED corrections depend on the masses and relative velocities of the daughter particles. We find that theoretical predictions for $R(D^{+})^{tau/mu}$ and $R(D^{0})^{tau/mu}$ can be amplified by $sim4%$ and $sim3%$, respectively, for the soft-photon energy cut in range $20$-$40$ MeV.
At present, the measurements of $R_{D^{(*)}}$ and $R_{J/psi}$ hint at new physics (NP) in $b to c tau^- {bar u}$ decays. The angular distribution of ${bar B} to D^* (to D pi) , tau^{-} {bar u}_tau$ would be useful for getting information about the NP , but it cannot be measured. The reason is that the three-momentum ${vec p}_tau$ cannot be determined precisely since the decay products of the $tau^-$ include an undetected $ u_tau$. In this paper, we construct a measurable angular distribution by considering the additional decay $tau^- to pi^- u_tau$. The full process is ${bar B} to D^* (to D pi) , tau^{-} (to pi^- u_tau) {bar u}_tau$, which includes three final-state particles whose three-momenta can be measured: $D$, $pi$, $pi^-$. The magnitudes and relative phases of all the NP parameters can be extracted from a fit to this angular distribution. One can measure CP-violating angular asymmmetries. If one integrates over some of the five kinematic parameters parametrizing the angular distribution, one obtains (i) familiar observables such as the $q^2$ distribution and the $D^*$ polarization, and (ii) new observables associated with the $pi^-$ emitted in the $tau$ decay: the forward-backward asymmetry of the $pi^-$ and the CP-violating triple-product asymmetry.
83 - S. Hirose , T. Iijima , I. Adachi 2016
We report the first measurement of the $tau$ lepton polarization $P_tau(D^*)$ in the decay $bar{B} rightarrow D^* tau^- bar{ u}_tau$ as well as a new measurement of the ratio of the branching fractions $R(D^{*}) = mathcal{B}(bar {B} rightarrow D^* ta u^- bar{ u}_tau) / mathcal{B}(bar{B} rightarrow D^* ell^- bar{ u}_ell)$, where $ell^-$ denotes an electron or a muon, and the $tau$ is reconstructed in the modes $tau^- rightarrow pi^- u_tau$ and $tau^- rightarrow rho^- u_tau$. We use the full data sample of $772 times 10^6$ $B{bar B}$ pairs recorded with the Belle detector at the KEKB electron-positron collider. Our results, $P_tau(D^*) = -0.38 pm 0.51 {rm (stat.)} ^{+0.21}_{-0.16} {rm (syst.)}$ and $R(D^*) = 0.270 pm 0.035{rm (stat.)} ^{+0.028}_{-0.025}{rm (syst.)}$, are consistent with the theoretical predictions of the Standard Model.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا