Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

184   0   0.0 ( 0 )
 نشر من قبل Gloria Spandre
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

An innovative X-ray imaging sensor with intrinsic digital characteristics is presented. It is based on Chromatic Photon Counting technology. The detector is able to count individually the incident X-ray photons and to separate them according to their energy (two color images per exposure). The energy selection occurs in real time and at radiographic imaging speed (GHz global counting rate). Photon counting, color mode and a very high spatial resolution (more than 10 l.p./mm at MTF50) allow to obtain an optimal ratio between image quality and absorbed dose. The individual block of the imaging system is a two-side buttable semiconductor radiation detector made of a thin pixellated CdTe crystal (the sensor) coupled to a large area VLSI CMOS pixel ASIC. 1, 2, 4, 8 tile units have been built. The 8 tiles unit has 25cm x 2.5cm sensitive area. Results and images obtained from in depth testing of several configurations of the system are presented. The X-Ray imaging system is the technological platform of PIXIRAD Imaging Counters s.r.l., a recently constituted INFN spin-off company.



قيم البحث

اقرأ أيضاً

The performance of hybrid GaAs pixel detectors as X-ray imaging sensors were investigated at room temperature. These hybrids consist of 300 mu-m thick GaAs pixel detectors, flip-chip bonded to a CMOS Single Photon Counting Chip (PCC). This chip consi sts of a matrix of 64 x 64 identical square pixels (170 mu-m x 170 mu-m) and covers a total area of 1.2 cm**2. The electronics in each cell comprises a preamplifier, a discriminator with a 3-bit threshold adjust and a 15-bit counter. The detector is realized by an array of Schottky diodes processed on semi-insulating LEC-GaAs bulk material. An IV-charcteristic and a detector bias voltage scan showed that the detector can be operated with voltages around 200 V. Images of various objects were taken by using a standard X-ray tube for dental diagnostics. The signal to noise ratio (SNR) was also determined. The applications of these imaging systems range from medical applications like digital mammography or dental X-ray diagnostics to non destructive material testing (NDT). Because of the separation of detector and readout chip, different materials can be investigated and compared.
A multi-pixel photon sensor with single-photon sensitivity has been developed, based on a technology of a hybrid photo-detector (HPD) consisting of a photocathode and a multi-pixel avalanche diode (MP-AD). The developed HPD has a proximity focused st ructure, where a photocathode and an MP-AD are facing each other with a small gap of 2.5 mm. The MP-AD, which has an effective area of 16x16 mm2 composed of 8x8 pixels, has been specially designed for the HPD. The gain of the HPD reaches 5x10^4, sufficiently high to detect single photons with a timing resolution better than 100 ps. Number of photoelectrons up to four can be clearly identified in a pulse-height spectrum as distinct peaks, thanks to the low noise characteristics of the HPD. It is also demonstrated that the HPD can be operated with good performance in a magnetic field as high as 1.5 T
SOI (Silicon-On-Insulator) pixel sensor is promising technology for developing the high position resolution detector by integrating the small pixels and circuits in the monolithic way. The event driven (trigger mode) SOI based pixel sensor has also b een developed for the application of X-ray astronomy with the purpose of reducing the noise using anti-coincidence event. This trigger mode SOI pixel sensor working with in the rate of kilo Hz is also a promising scatter detector for advanced Compton imaging to track the Compton recoiled electrons.
A micro time-projection-chamber (micro-TPC) with a detection volume of 23*28*31 cm^3 was developed, and its fundamental performance was examined. The micro-TPC consists of a micro pixel chamber with a detection area of 31*31 cm^2 as a two-dimensional imaging device and a gas electron multiplier with an effective area of 23*28 cm^2 as a pre-gas-multiplier. The micro-TPC was operated at a gas gain of 50,000, and energy resolutions and spatial resolutions were measured.
A vacuum-compatible photon-counting hybrid pixel detector has been installed in the ultra-high vacuum (UHV) reflectometer of the four-crystal monochromator (FCM) beamline of the Physikalisch-Technische Bundesanstalt (PTB) at the electron storage ring BESSY II in Berlin, Germany. The setup is based on the PILATUS3 100K module. The detector can be used in the entire photon energy range accessible at the beamline from 1.75 to 10 keV. Complementing the already installed vacuum-compatible PILATUS 1M detector used for small-angle scattering (SAXS) and grazing incidence SAXS (GISAXS), it is possible to access larger scattering angles. The water-cooled module is located on the goniometer arm and can be positioned from -90{deg} to 90{deg} with respect to the incoming beam at a distance of about 200 mm from the sample. To perform absolute scattering experiments the linearity, homogeneity and the angular dependence of the quantum efficiency, including their relative uncertainties, have been investigated. In addition, first results of the performance in wide-angle X-ray scattering (WAXS), X-ray diffraction (XRD) and X-ray reflectometry (XRR) are presented.