The electromagnetic calorimeter of the AMS-02 experiment

407   0   0.0 ( 0 )
 نشر من قبل Manuela Vecchi
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structure, it can also provide the separation of positrons from protons, in the GeV to TeV region. A direct measurement of high energy photons with accurate energy and direction determination can also be provided.

قيم البحث

اقرأ أيضاً

The Alpha Magnetic Spectrometer (AMS), whose final version AMS-02 is to be installed on the International Space Station (ISS) for at least 3 years, is a detector designed to measure charged cosmic ray spectra with energies up to the TeV region and wi th high energy photon detection capability up to a few hundred GeV, using state-of-the-art particle identification techniques. Following the successful flight of the detector prototype (AMS-01) aboard the space shuttle, AMS-02 is expected to provide a significant improvement on the current knowledge of the elemental and isotopic composition of hadronic cosmic rays due to its long exposure time (minimum of 3 years) and large acceptance (0.5 m^2 sr) which will enable it to collect a total statistics of more than 10^10 nuclei. Detector capabilities for charge, velocity and mass identification, estimated from ion beam tests and detailed Monte Carlo simulations, are presented. Relevant issues in cosmic ray astrophysics addressed by AMS-02, including the test of cosmic ray propagation models, galactic confinement times and the influence of solar cycles on the local cosmic ray flux, are briefly discussed.
A lead-glass hodoscope calorimeter that was constructed for use in the Jefferson Lab Real Compton Scattering experiment is described. The detector provides a measurement of the coordinates and the energy of scattered photons in the GeV energy range w ith resolutions of 5 mm and 6%/sqrt(E{gamma} [GeV]). Features of both the detector design and its performance in the high luminosity environment during the experiment are presented.
The Heavy Photon Search experiment (HPS) is searching for a new gauge boson, the so-called heavy photon. Through its kinetic mixing with the Standard Model photon, this particle could decay into an electron-positron pair. It would then be detectable as a narrow peak in the invariant mass spectrum of such pairs, or, depending on its lifetime, by a decay downstream of the production target. The HPS experiment is installed in Hall-B of Jefferson Lab. This article presents the design and performance of one of the two detectors of the experiment, the electromagnetic calorimeter, during the runs performed in 2015-2016. The calorimeters main purpose is to provide a fast trigger and reduce the copious background from electromagnetic processes through matching with a tracking detector. The detector is a homogeneous calorimeter, made of 442 lead-tungstate (PbWO4) scintillating crystals, each read out by an avalanche photodiode coupled to a custom trans-impedance amplifier.
118 - I.S. Lee , S.H. Kim , C.H. Kim 2018
The Belle II experiment at KEK in Japan has started real data taking from April 2018 to probe a New Physics beyond the Standard Model by measuring CP violation precisely and rare weak decays of heavy quark and lepton. The experiment is performed at t he high luminosity SuperKEKB e^+ e^- collider with 80 x 10^34 cm^-2 s^-1 as an ultimate instantaneous luminosity. In order to develop and test an appropriate trigger algorithm under much higher luminosity and beam background environment than previous KEKB collider, a detail simulation study of the Belle II calorimeter trigger system is very crucial to operate Belle II Trigger and DAQ system in stable. We report preliminary results on various trigger logics and their efficiencies using physics and beam background Monte Carlo events with a Belle II Geant4-based analysis framework called Basf2.
The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to measure the neutrino mass with a sensitivity of $0.2,eV$ ($90,%$ CL). This will be achieved by a precision measurement of the endpoint region of the $beta$-electron spectrum of tritium decay. The electrons from tritium $beta$-decay are produced in the Windowless Gaseous Tritium Source (WGTS) and guided magnetically through the beamline. In order to accurately extract the neutrino mass the source properties, in particular the activity, are required to be stable and known to a high precision. The WGTS therefore undergoes constant extensive monitoring from several measurement systems. The Forward Beam Monitor (FBM) is one such monitoring system. The FBM system comprises a complex mechanical setup capable of inserting a detector board into the KATRIN beamline inside the Cryogenic Pumping Section with a positioning precision of better than $0.3,mm$. The electron flux density at that position is on the order of $10^{6},s^{-1}mm^{-2}$. The detector board contains a hall sensor, a temperature gauge, and two silicon detector chips of $textit{p}$-$textit{i}$-$textit{n}$ diode type which can measure the $beta$-electron flux from the source with a precision of $0.1,%$ in less than a minute with an energy resolution of FWHM = $2,keV$.