ترغب بنشر مسار تعليمي؟ اضغط هنا

Suppression of quantum-radiation-pressure noise in an optical spring

98   0   0.0 ( 0 )
 نشر من قبل W. Zach Korth
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Recent advances in micro- and nanofabrication techniques have led to corresponding improvement in the performance of optomechanical systems, which provide a promising avenue towards quantum-limited metrology and the study of quantum behavior in macroscopic mechanical objects. One major impediment to reaching the quantum regime is thermal excitation, which can be overcome for sufficiently high mechanical quality factor Q. Here, we propose a method for increasing the effective Q of a mechanical resonator by stiffening it via the optical spring effect exhibited by linear optomechanical systems, and show how the associated quantum radiation pressure noise can be evaded by sensing and feedback control. In a parameter regime that is attainable with current technology, this method allows for realistic quantum cavity optomechanics in a frequency band well below that which has been realized thus far.

قيم البحث

اقرأ أيضاً

We investigate the reduction of the electromagnetic field fluctuations in resonance fluorescence from a single emitter coupled to an optical nanostructure. We find that such hybrid system can lead to the creation of squeezed states of light, with qua ntum fluctuations significantly below the shot noise level. Moreover, the physical conditions for achieving squeezing are strongly relaxed with respect to an emitter in free space. A high degree of control over squeezed light is feasible both in the far and near fields, opening the pathway to its manipulation and applications on the nanoscale with state-of-the-art setups.
We examine the effect of different sources of technical noise on inverse weak value-based precision phase measurements. We find that this type of measurement is similarly robust to technical noise as related experiments in the weak value regime. In p articular, the measurements considered here are robust to additive Gaussian white noise and angular jitter noise commonly encountered in optical experiments. Additionally, we show the same techniques used for precision phase measurement can be used with the same technical advantages for optical frequency measurements.
In our previous research, simulation showed that a quantum locking scheme with homodyne detection in sub-cavities is effective in surpassing the quantum noise limit for Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) in a limited fr equency range. This time we have simulated an optical spring effect in the sub-cavities of the quantum locking scheme. We found that the optimized total quantum noise is reduced in a broader frequency band, compared to the case without the optical spring effect significantly improving the sensitivity of DECIGO to the primordial gravitational waves.
Experiments involving optical traps often require careful control of the ac Stark shifts induced by strong confining light fields. By carefully balancing light shifts between two atomic states of interest, optical traps at the magic wavelength have b een especially effective at suppressing deleterious effects stemming from such shifts. Highlighting the power of this technique, optical clocks today exploit Lamb-Dicke confinement in magic-wavelength optical traps, in some cases realizing shift cancellation at the ten parts per billion level. Theory and empirical measurements can be used at varying levels of precision to determine the magic wavelength where shift cancellation occurs. However, lasers exhibit background spectra from amplified spontaneous emission or other lasing modes which can easily contaminate measurement of the magic wavelength and its reproducibility in other experiments or conditions. Indeed, residual light shifts from laser background have plagued optical lattice clock measurements for years. In this work, we develop a simple theoretical model allowing prediction of light shifts from measured background spectra. We demonstrate good agreement between this model and measurements of the background light shift from an amplified diode laser in an Yb optical lattice clock. Additionally, we model and experimentally characterize the filtering effect of a volume Bragg grating bandpass filter, demonstrating that application of the filter can reduce background light shifts from amplified spontaneous emission well below the $10^{-18}$ fractional clock frequency level. This demonstration is corroborated by direct clock comparisons between a filtered amplified diode laser and a filtered titanium:sapphire laser.
We measure the fundamental noise processes associated with a continuous linear position measurement of a micromechanical membrane incorporated in a microwave cavity optomechanical circuit. We observe the trade-off between the two fundamental sources of noises that enforce the standard quantum limit: the measurement imprecision and radiation-pressure backaction from photon shot noise. We demonstrate that the quantum backaction of the measurement can overwhelm the intrinsic thermal motion by 24 dB, entering a new regime for cavity optomechanical systems.