31   0   0.0 ( 0 )
 نشر من قبل Claude Amsler
 تاريخ النشر 2007
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

While developing a liquid argon detector for dark matter searches we investigate the influence of air contamination on the VUV scintillation yield in gaseous argon at atmospheric pressure. We determine with a radioactive alpha-source the photon yield for various partial air pressures and different reflectors and wavelength shifters. We find for the fast scintillation component a time constant tau1= 11.3 +- 2.8 ns, independent of gas purity. However, the decay time of the slow component depends on gas purity and is a good indicator for the total VUV light yield. This dependence is attributed to impurities destroying the long-lived argon excimer states. The population ratio between the slowly and the fast decaying excimer states is determined for alpha-particles to be 5.5 +-0.6 in argon gas at 1100 mbar and room temperature. The measured mean life of the slow component is tau2 = 3.140 +- 0.067 microsec at a partial air pressure of 2 x 10-6 mbar.

قيم البحث

اقرأ أيضاً

We measure the ratio $gamma$ of the momentum-transfer to the vibrational quenching cross section for the X ($^1Sigma^+$), $ u=1$, $mathrm{J=0}$ state of molecular thorium monoxide (ThO) in collisions with atomic $^3$He between 800 mK and 2.4 K. We ob serve indirect evidence for ThO--He van der Waals complex formation, which has been predicted by theory. We determine the 3-body recombination rate constant $Gamma_3$ at 2.4 K, and establish that the binding energy E$_b >$ 4 K.
We have built a gas-phase argon ionization detector to measure small nuclear recoil energies (< 10 keVee). In this paper, we describe the detector response to X-ray and gamma calibration sources, including analysis of pulse shapes, software triggers, optimization of gas content, and energy- and position-dependence of the signal. We compare our experimental results against simulation using a 5.9-keV X-ray source, as well as higher-energy gamma sources up to 1332 keV. We conclude with a description of the detector, DAQ, and software settings optimized for a measurement of the low-energy nuclear quenching factor in gaseous argon. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory in part under Contract W-7405-Eng-48 and in part under Contract DE-AC52-07NA27344. Funded by Lab-wide LDRD. LLNL-JRNL-415990-DRAFT.
Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI photocathode deposited on the first THGEM. A gain of $8cdot10^{5}$ per photoelectron and $sim100%$ photoelectron collection efficiency are measured at stable operation settings. The excellent position resolution capabilities of the detector (better than 100 $mu$m) at 100 kHz readout rate, is demonstrated at room temperature. Structural integrity tests of the detector and seals are successfully performed at cryogenic temperatures by immersing the detector in liquid Nitrogen, laying a good foundation for future operation tests in noble liquids.
Pulse-shape discrimination (PSD) is usually achieved using the different fast and slow decay components of inorganic scintillators, such as BaF2, CsI:Tl, etc. However, LaBr3:Ce is considered to not possess different components at room temperature, bu t has been proved to have the capability of discriminating {gamma} and {alpha} events using fast digitizers. In this paper, ionization-density-dependent transport and rate equations are used to quantitatively model the competing processes in a particle track. With one parameter set, the model reproduces the nonproportionality response of electrons or {alpha} particles, and explains the measured {alpha} and {gamma} pulse-shape difference well. In particular, the nonlinear quenching of excited dopant ions, Ce3+, is confirmed herein to mainly contribute observable ionization {alpha} and {gamma} pulse-shape differences. Further study of the luminescence quenching can also help to better understand the fundamental physics of nonlinear quenching and thus improve the crystal engineering. Moreover, based on the mechanism of dopant quenching, the ionization-density-dependent pulse-shape differences in other fast single-decay-component inorganic scintillators, such as lutetium yttrium oxyorthosilicate, Lu2(1-x)Y2xSiO5:Ce (LYSO) and CeBr3, are also predicted and verified with experiments.
The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.