ترغب بنشر مسار تعليمي؟ اضغط هنا

Comment on the article ``UCN anomalous losses and the UCN capture cross section on material defects by A. Serebrov et al

55   0   0.0 ( 0 )
 نشر من قبل Konstantin Protasov
 تاريخ النشر 2005
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

We present correct solution of the problem about a scattering of the neutron on a point-like defect existing in a medium and show that this mechanism cannot explain anomalous losses of UCN in storage bottles.



قيم البحث

اقرأ أيضاً

The CLAS Collaboration provides a comment on the physics interpretation of the results presented in a paper published by M. Amaryan et al. regarding the possible observation of a narrow structure in the mass spectrum of a photoproduction experiment.
It is shown that the continuum limit of the spin 1/2 Heisenberg XYZ model is far from sufficient for the site number of 16. Therefore, the energy spectrum of the XYZ model obtained by Kolanovic et al. has nothing to do with the massive Thirring model , but it shows only the spectrum of the finite size effects.
56 - Omar Benhar 2020
The article of Pastore et al, while proposing an interesting and potentially useful approach for the generalisation of Quantum Monte Carlo techniques to the treatment of the nuclear electromagnetic response, features an incorrect and misleading discu ssion of y-scaling. The response to interactions with transversely polarised virtual photons receives sizeable contributions from non-scaling processes, in which the momentum transfer is shared between two nucleons. It follows that, contrary to what is stated by the the authors, y-scaling in the transverse channel is accidental.
209 - V. Fischer 2019
The use of argon as a detection and shielding medium for neutrino and dark matter experiments has made the precise knowledge of the cross section for neutron capture on argon an important design and operational parameter. Since previous measurements were averaged over thermal spectra and have significant disagreements, a differential measurement has been performed using a Time-Of-Flight neutron beam and a $sim$4$pi$ gamma spectrometer. A fit to the differential cross section from $0.015-0.15$,eV, assuming a $1/v$ energy dependence, yields $sigma^{2200} = 673 pm 26 text{ (stat.)} pm 59 text{ (sys.)}$,mb.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا