Super-LOTIS: A High-Sensitive Optical Counterpart Search Experiment

57   0   0.0 ( 0 )
 نشر من قبل George Grant Williams
 تاريخ النشر 1997
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We are constructing a 0.6 meter telescope system to search for early time gamma-ray burst(GRB) optical counterparts. Super-LOTIS (Super-Livermore Optical Transient Imaging System) is an automated telescope system that has a 0.8 x 0.8 deg field-of-view, is sensitive to Mv ~ 19 and responds to a burst trigger within 5 min. This telescope will record images of the gamma-ray burst coordinates that is given by the GCN (GRB Coordinate Network). A measurement of GRB light curves at early times will greatly enhance our understanding of GRB physics.



قيم البحث

اقرأ أيضاً

We present multi-instrument optical observations of the High Energy Transient Explorer (HETE-2)/Interplanetary Network (IPN) error box of GRB 010921. This event was the first gamma ray burst (GRB) localized by HETE-2 which has resulted in the detecti on of an optical afterglow. In this paper we report the earliest known observations of the GRB010921 field, taken with the 0.11-m Livermore Optical Transient Imaging System (LOTIS) telescope, and the earliest known detection of the GRB010921 optical afterglow, using the 0.5-m Sloan Digital Sky Survey Photometric Telescope (SDSS PT). Observations with the LOTIS telescope began during a routine sky patrol 52 minutes after the burst. Observations were made with the SDSS PT, the 0.6-m Super-LOTIS telescope, and the 1.34-m Tautenburg Schmidt telescope at 21.3, 21.8, and 37.5 hours after the GRB, respectively. In addition, the host galaxy was observed with the USNOFS 1.0-m telescope 56 days after the burst. We find that at later times (t > 1 day after the burst), the optical afterglow exhibited a power-law decline with a slope of $alpha = 1.75 pm 0.28$. However, our earliest observations show that this power-law decline can not have extended to early times (t < 0.035 day).
We report on the very early time search for an optical afterglow from GRB 971227 with the Livermore Optical Transient Imaging System (LOTIS). LOTIS began imaging the `Original BATSE error box of GRB 971227 approximately 14 s after the onset of gamma- ray emission. Continuous monitoring of the position throughout the evening yielded a total of 499 images (10 s integration). Analysis of these images revealed no steady optical afterglow brighter than R=12.3 +- 0.2 in any single image. Coaddition of different combinations of the LOTIS images also failed to uncover transient optical emission. In particular, assuming a constant early time flux, no optical afterglow brighter than R=14.2 +- 0.2 was present within the first 1200 s and no optical afterglow brighter than R=15.0 +- 0.2 was present in the first 6.0 h. Follow up observations by other groups revealed a likely X-ray afterglow and a possible optical afterglow. Although subsequent deeper observations could not confirm a fading source, we show that these transients are not inconsistent with our present knowledge of the characteristics of GRB afterglows. We also demonstrate that with the upgraded thermoelectrically cooled CCDs, LOTIS is capable of either detecting very early time optical afterglow or placing stringent constraints on the relationship between the gamma-ray emission and the longer wavelength afterglow in relativistic blast wave models.
LOTIS is a gamma-ray burst optical counterpart search experiment located near Lawrence Livermore National Laboratory in California. Since operations began in October 1996, LOTIS has responded to five triggers as of July 30, 1997, which occurred durin g good weather conditions. GRB970223 (BATSE Trigger #6100) was an exceptionally strong burst lasting $sim30$ s with a peak at $sim8$ s. LOTIS began imaging the error box $sim 11$ s after the burst began, and achieved simultaneous optical coverage of 100% of the region enclosed by the BATSE $3sigma$ error circle and the IPN annulus. No optical transients were observed brighter than the m$_V sim 11$ completeness limit of the resulting images providing a new upper limit on the simultaneous optical to gamma-ray fluence ratio of $R_L < 1.1 times 10^{-4}$ and on the simultaneous optical (at 700 nm) to gamma-ray (at 100 keV) flux density ratio of $R_F < 305$ for a B type spectrum and $R_F < 475$ for an M type spectrum.
61 - E. Aprile 2002
XENON is a novel liquid xenon experiment concept for a sensitive dark matter search using a 1-tonne active target, distributed in an array of ten independent time projection chambers. The design relies on the simultaneous detection of ionization and scintillation signals in liquid xenon, with the goal of extracting as much information as possible on an event-by-event basis, while maintaining most of the target active. XENON is expected to have effective and redundant background identification and discrimination power, higher than 99.5%, and to achieve a very low threshold, on the order of 4 keV visible recoil energy. Based on this expectation and the 1-tonne mass of active xenon, we project a sensitivity of 0.0001 events/kg/day, after 3 yr operation in an appropriate underground location. The XENON experiment has been recently proposed to the National Science Foundation (NSF) for an initial development phase leading to the development of the 100 kg unit module.
195 - Martin Durant , 2011
We report broad-band Hubble Space Telescope imaging of the field of soft gamma-ray repeater SGR 0418+5729 with ACS/WFC and WFC3/IR. Observing in two wide filters F606W and F110W, we find no counterpart within the positional error circle derived from Chandra observations, to limiting magnitudes mF606W>28.6, mF110W>27.4 (Vega system), equivalent to reddening-corrected luminosity limits LF606W<5e28, LF110W<6e28 erg s-1 for a distance d=2 kpc, at 3sig confidence. This, in turn, imposes lower limits on the contemporaneous X-ray/optical flux ratio of 1100 and X-ray/near-infra-red flux ratio of 1000. We derive an upper limit on the temperature and/or size of any fall-back disk around the magnetar. We also compare the detection limits with observations of other magnetars.