ترغب بنشر مسار تعليمي؟ اضغط هنا

The O VI Absorbers Toward PG0953+415: High Metallicity, Cosmic-Web Gas Far From Luminous Galaxies

84   0   0.0 ( 0 )
 نشر من قبل Todd M. Tripp
 تاريخ النشر 2006
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Todd M. Tripp




اسأل ChatGPT حول البحث

The spectrum of the low-redshift QSO PG0953+415 shows two strong, intervening O VI absorption systems. To study the nature of these absorbers, we have used the Gemini Multiobject Spectrograph to conduct a deep spectroscopic galaxy redshift survey in the 5 x 5 field centered on the QSO. This survey is fully complete for r < 19.7 and is 73% complete for r < 21.0. We find three galaxies at the redshift of the higher-z O VI system (z = 0.14232) including a galaxy at projected distance rho = 155 kpc. We find no galaxies in the Gemini field at the redshift of the lower-z O VI absorber (z = 0.06807), which indicates that the nearest galaxy is more than 195 kpc away or has L < 0.04 L*. Previous shallower surveys covering a larger field have shown that the z = 0.06807 O VI absorber is affiliated with a group/filament of galaxies, but the nearest known galaxy has rho = 736 kpc. The z = 0.06807 absorber is notable for several reasons. The absorption profiles reveal simple kinematics indicative of quiescent material. The H I line widths and good alignment of the H I and metal lines favor photoionization and, moreover, the column density ratios imply a high metallicity: [M/H] = -0.3 +/- 0.12. The z = 0.14232 O VI system is more complex and less constrained but also indicates a relatively high metallicity. Using galaxy redshifts from SDSS, we show that both of the PG0953+415 O VI absorbers are located in large-scale filaments of the cosmic web. Evidently, some regions of the web filaments are highly metal enriched. We discuss the origin of the high-metallicity gas and suggest that the enrichment might have occurred long ago (at high z).

قيم البحث

اقرأ أيضاً

101 - B. Savage , T.-S. Kim , B. Keeney 2012
Ultraviolet observations of the QSO 3C 263 (zem = 0.652) with COS and FUSE reveal O VI absorption systems at z = 0.06342 and 0.14072 . WIYN multi-object spectrograph observations provide information about the galaxies associated with the absorbers. T he multi-phase system at z = 0.06342 traces cool photoionized gas and warm collisionally ionized gas associated with a L ~ 0.31L* compact spiral emission line galaxy with an impact parameter of 63 kpc. The cool photoionized gas in the absorber is well modeled with log U ~ -2.6, log N(H) ~17.8, log n(H) ~ -3.3 and [Si/H] = -0.14pm0.23. The collisionally ionized gas containing C IV and O VI probably arises in cooling shock heated transition temperature gas with log T ~ 5.5. The absorber is likely tracing circumgalactic gas enriched by gas ejected from the spiral emission line galaxy. The simple system at z = 0.14072 only contains O VI and broad and narrow H I. The O VI with b = 33.4pm11.9 km s-1 is likely associated with the broad H I {lambda}1215 absorption with b = 86.7pm15.4 km s-1. The difference in Doppler parameters implies the detection of a very large column of warm gas with log T = 5.61(+0.16, -0.25), log N(H) = 19.54(+0.26, -0.44) and [O/H] = -1.48 (+0.46, -0.26). This absorber is possibly associated with a 1.6L* absorption line galaxy with an impact parameter of 617 kpc although an origin in warm filament gas or in the halo of a fainter galaxy is more likely.
We investigate the relationship between galaxies and metal-line absorption systems in a large-scale cosmological simulation with galaxy formation. Our detailed treatment of metal enrichment and non-equilibrium calculation of oxygen species allow us, for the first time, to carry out quantitative calculations of the cross-correlations between galaxies and O VI absorbers. We find the following: (1) The cross-correlation strength depends weakly on the absorption strength but strongly on the luminosity of the galaxy. (2) The correlation distance increases monotonically with luminosity from ~0.5-1h^-1 Mpc for 0.1L* galaxies to ~3-5h^-1 Mpc for L* galaxies. (3) The correlation distance has a complicated dependence on absorber strength, with a luminosity-dependent peak. (4) Only 15% of O VI absorbers lie near >=Lz* galaxies. The remaining 85%, then, must arise ``near lower-luminosity galaxies, though, the positions of those galaxies is not well-correlated with the absorbers. This may point to pollution of intergalactic gas predominantly by smaller galaxies. (5) There is a subtle trend that for >~0.5Lz* galaxies, there is a positive correlation between absorber strength and galaxy luminosity in the sense that stronger absorbers have a slightly higher probability of finding such a large galaxy at a given projection distance. For less luminous galaxies, there seems to be a negative correlation between luminosity and absorber strength.
High signal-to-noise (S/N) observations of the QSO PKS 0405-123 (zem = 0.572) with the Cosmic Origins Spectrograph from 1134 to 1796 A with a resolution of 17 km s-1 are used to study the multi-phase partial Lyman limit system (LLS) at z = 0.16716 wh ich has previously been studied using relatively low S/N spectra from STIS and FUSE. The LLS and an associated H I-free broad O VI absorber likely originate in the circumgalactic gas associated with a pair of galaxies at z = 0.1688 and 0.1670 with impact parameters of 116 h70-1 and 99 h70-1. The broad and symmetric O VI absorption is detected in the z = 0.16716 restframe with v = -278 +/- 3 km s-1, log N(O VI) = 13.90 +/- 0.03 and b = 52 +/- 2 km s-1. This absorber is not detected in H I or other species with the possible exception of N V . The broad, symmetric O VI profile and absence of corresponding H I absorption indicates that the circumgalactic gas in which the collisionally ionized O VI arises is hot (log T ~ 5.8-6.2). The absorber may represent a rare but important new class of low z IGM absorbers. The LLS has strong asymmetrical O VI absorption with log N(O VI) = 14.72 +/- 0.02 spanning a velocity range from -200 to +100 km s-1. The high and low ions in the LLS have properties resembling those found for Galactic highly ionized HVCs where the O VI is likely produced in the conductive and turbulent interfaces between cool and hot gas.
We report on the observed properties of the plasma revealed through high signal-to-noise (S/N) observations of 54 intervening O VI absorption systems containing 85 O VI and 133 H I components in a blind survey of 14 QSOs observed at ~18 km s-1 resolu tion with the Cosmic Origins Spectrograph (COS) over a redshift path of 3.52 at z < 0.5. Simple systems with one or two H I components and one O VI component comprise 50% of the systems. For a sample of 45 well-aligned absorption components where the temperature can be estimated, we find evidence for cool photoionized gas in 31 (69%) and warm gas (6 > log T > 5) in 14 (31%) of the components. The total hydrogen content of the 14 warm components can be estimated from the temperature and the measured value of log N(H I). The very large implied values of log N(H) range from 18.38 to 20.38 with a median of 19.35. The metallicity, [O/H], in the 6 warm components with log T > 5.45 ranges from -1.93 to 0.03 with a median value of -1.0 dex. Ground-based galaxy redshift studies reveal that most of the absorbers we detect sample gas in the IGM extending 200 to 600 kpc beyond the closest associated galaxy. We estimate the warm aligned O VI absorbers contain (4.1+/-1.1)% of the baryons at low z. The warm plasma traced by the aligned O VI and H I absorption contains nearly as many baryons as are found in galaxies.
[Abridged] We present a detailed study of the largest sample of intervening O VI systems in the redshift range 1.9 < z < 3.1 detected in high resolution (R ~ 45,000) spectra of 18 bright QSOs observed with VLT/UVES. Based on Voigt profile and apparen t optical depth analysis we find that (i) the Doppler parameters of the O VI absorption are usually broader than those of C IV (ii) the column density distribution of O VI is steeper than that of C IV (iii) line spread (delta v) of the O VI and C IV are strongly correlated (at 5.3sigma level) with delta v(O VI) being systematically larger than delta v(C IV) and (iv) delta v(O VI) and delta v(C IV) are also correlated (at > 5sigma level) with their respective column densities and with N(H I) (3 and 4.5 sigma respectively). These findings favor the idea that C IV and O VI absorption originate from different phases of a correlated structure and systems with large velocity spread are probably associated with overdense regions. The velocity offset between optical depth weighted redshifts of C IV and O VI absorption is found to be in the range 0 < |Delta v (O VI - CIV)| < 48 km/s with a median value of 8 km/s. We compare the properties of O VI systems in our sample with that of low redshift (z < 0.5) samples from the literature and find that (i) the O VI components at low-z are systematically wider than at high-z with an enhanced non-thermal contribution to their b-parameter, (ii) the slope of the column density distribution functions for high and low-z are consistent, (iii) range in gas temperature estimated from a subsample of well aligned absorbers are similar at both high and low-z, and (iv) Omega_{O VI} = (1.0 pm 0.2) times10^{-7} for N(O VI) > 10^{13.7} cm^{-2}, estimated in our high-z sample, is very similar to low-z estimations.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا