ترغب بنشر مسار تعليمي؟ اضغط هنا

XMM-Newton observation of the Soft Gamma Ray Repeater SGR 1627-41 in a low luminosity state

57   0   0.0 ( 0 )
 نشر من قبل Sandro Mereghetti
 تاريخ النشر 2005
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The sky region containing the soft gamma-ray repeater SGR 1627-41 has been observed three times with XMM-Newton in February and September 2004. SGR 1627-41 has been detected with an absorbed flux of ~9x10^{-14} erg cm^{-2} s^{-1} (2-10 keV). For a distance of 11 kpc, this corresponds to a luminosity of ~3x10^{33} erg s^{-1}, the smallest ever observed for a Soft Gamma Repeater and possibly related to the long period of inactivity of this source. The observed flux is smaller than that seen with Chandra in 2001-2003, suggesting that the source was still fading and had not yet reached a steady quiescent level. The spectrum is equally well fit by a steep power law (photon index ~3.2) or by a blackbody with temperature kT~0.8 keV. We also report on the INTEGRAL transient IGR J16358-4726 that lies at ~10 from SGR 1627-41. It was detected only in September 2004 with a luminosity of ~4x10^{33} erg s^{-1} (for d=7 kpc), while in February 2004 it was at least a factor 10 fainter.



قيم البحث

اقرأ أيضاً

82 - S. Corbel 1999
We report millimeter observations of the line of sight to the recently discovered Soft Gamma Repeater, SGR 1627-41, which has been tentatively associated with the supernova remnant SNR G337.0-0.1 Among the eight molecular clouds along the line of sig ht to SGR 1627-41, we show that SNR G337.0-0.1 is probably interacting with one of the most massive giant molecular clouds (GMC) in the Galaxy, at a distance of 11 kpc from the sun. Based on the high extinction to the persistent X-ray counterpart of SGR 1627-41, we present evidence for an association of this new SGR with the SNR G337.0-0.1; they both appear to be located on the near side of the GMC. This is the second SGR located near an extraordinarily massive GMC. We suggest that SGR 1627-41 is a neutron star with a high transverse velocity (~ 1,000 kms) escaping the young (~ 5,000 years) supernova remnant G337.0-0.1
SGR 1627-41 was discovered in 1998 after a single active episode which lasted ~6 weeks. We report here our monitoring results of the decay trend of the persistent X-ray luminosity of the source during the last 5 years. We find an initial temporal pow er law decay with index 0.47, reaching a plateau which is followed by a sharp (factor of ten) flux decline ~800 days after the source activation. The source spectrum is best described during the entire period by a single power law with high absorption (N_H=9.0(7)x10^(22) cm^(-2)); the spectral index, however, varies dramatically between 2.2-3.8 spanning the entire range for all known SGR sources. We discuss the cooling behavior of the neutron star assuming a deep crustal heating initiated by the burst activity of the source during 1998.
Using Chandra data taken on 2008 June, we detected pulsations at 2.59439(4) s in the soft gamma-ray repeater SGR 1627-41. This is the second measurement of the source spin period and allows us to derive for the first time a long-term spin-down rate o f (1.9 +/- 0.4)E-11 s/s. From this value we infer for SGR 1627-41 a characteristic age of 2.2 kyr, a spin-down luminosity of 4E+34 erg/s (one of the highest among sources of the same class), and a surface dipole magnetic field strength of 2E+14 G. These properties confirm the magnetar nature of SGR 1627-41; however, they should be considered with caution since they were derived on the basis of a period derivative measurement made using two epochs only and magnetar spin-down rates are generally highly variable. The pulse profile, double-peaked and with a pulsed fraction of (13 +/- 2)% in the 2-10 keV range, closely resembles that observed by XMM-Newton in 2008 September. Having for the first time a timing model for this SGR, we also searched for a pulsed signal in archival radio data collected with the Parkes radio telescope nine months after the previous X-ray outburst. No evidence for radio pulsations was found, down to a luminosity level 10-20 times fainter (for a 10% duty cycle and a distance of 11 kpc) than the peak luminosity shown by the known radio magnetars.
85 - S. Mereghetti 2005
The low energy (<10 keV) X-ray emission of the Soft Gamma-ray Repeater SGR1806-20 has been studied by means of four XMM-Newton observations carried out in the last two years, the latter performed in response to a strong sequence of hard X-ray bursts observed on 2004 October 5. The source was caught in different states of activity: over the 2003-2004 period the 2-10 keV flux doubled with respect to the historical level observed previously. The long term raise in luminosity was accompanied by a gradual hardening of the spectrum, with the power law photon index decreasing from 2.2 to 1.5, and by a growth of the bursting activity. The pulse period measurements obtained in the four observations are consistent with an average spin-down rate of 5.5x10e-10 s/s, higher than the values observed in the previous years. The long-term behavior of SGR1806-20 exhibits the correlation between spectral hardness and spin-down rate previously found only by comparing the properties of different sources (both SGRs and Anomalous X-ray Pulsars). The best quality spectrum (obtained on 6 September 2004) cannot be fitted by a single power law, but it requires an additional blackbody component (kT=0.79 keV, R_BB = 1.9 (d/15 kpc)^2 km), similar to the spectra observed in other SGRs and in Anomalous X-ray Pulsars. No spectral lines were found in the persistent emission, with equivalent width upper limits in the range 30-110 eV. Marginal evidence for an absorption feature at 4.2 keV is present in the cumulative spectrum of 69 bursts detected in September-October 2004.
220 - T. Enoto , Y.E. Nakagawa , N. Rea 2009
We present the first Suzaku observation of the new Soft Gamma Repeater SGR 0501+4516, performed on 2008 August 26, four days after the onset of bursting activity of this new member of the magnetar family. The soft X-ray persistent emission was detect ed with the X-ray Imaging Spectrometer (XIS) at a 0.5-10 keV flux of 3.8E-11 erg/s/cm2, with a spectrum well fitted by an absorbed blackbody plus power-law model. The source pulsation was confirmed at a period of 5.762072+/-0.000002 s, and 32 X-ray bursts were detected by the XIS, four of which were also detected at higher energies by the Hard X-ray Detector (HXD). The strongest burst, which occurred at 03:16:16.9 (UTC), was so bright that it caused instrumental saturation, but its precursor phase, lasting for about 200 ms, was detected successfully over the 0.5-200 keV range, with a fluence of ~2.1E-7 erg/cm2 and a peak intensity of about 89 Crab. The entire burst fluence is estimated to be ~50 times higher. The precursor spectrum was very hard, and well modeled by a combination of two blackbodies. We discuss the bursting activity and X/gamma-ray properties of this newly discovered Soft Gamma Repeater in comparison with other members of the class.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا