ترغب بنشر مسار تعليمي؟ اضغط هنا

A BeppoSAX-WFC viewpoint of new INTEGRAL sources, particularly IGR J17544-2619

339   0   0.0 ( 0 )
 نشر من قبل Jean In 't Zand
 تاريخ النشر 2004
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Of the 21 new sources that INTEGRAL discovered up to Feb. 1, 2004, five were detected with the BeppoSAX Wide Field Cameras at earlier times. IGR J16320-4751 appears to be a persistently active X-ray source which hints at a supergiant Roche-lobe overflowing companion star in this proposed high-mass X-ray binary. IGR J17091-3624 is a transient source that was detected in 1996 and 2001 with a maximum flux of 20 mCrab (2-28 keV). It is either a Be X-ray binary or a low mass X-ray binary transient. IGR J18483-0311 may be a high-mass X-ray binary, because it is located in a region rich of such objects, just like IGR J19140+098. IGR J17544-2619 appears to be a frequently active X-ray source whose hours-long flares, of which WFC detected five, are reminiscent of the stellar black hole source V4641 Sgr. We discuss this source in detail.


قيم البحث

اقرأ أيضاً

X-ray photons coming from an X-ray point source not only arrive at the detector directly, but also can be strongly forward-scattered by the interstellar dust along the line of sight (LOS), leading to a detectable diffuse halo around the X-ray point s ource. The geometry of small angle X-ray scattering is straightforward, namely, the scattered photons travel longer paths and thus arrive later than the unscattered ones; thus the delay time of X-ray scattered halo photons can reveal information of the distances of the interstellar dust and the point source. Here we present a study of the X-ray scattered around IGR J17544-2619, which is one of the so-called supergiant fast X-ray transients. IGR J17544-2619 underwent a striking outburst when observed with Chandra on 2004 July 3, providing a near delta-function lightcurve. We find that the X-ray scattered halo around IGR J17544-2619 is produced by two interstellar dust clouds along the LOS. The one which is closer to the observer gives the X-ray scattered at larger observational angles; whereas the farther one, which is in the vicinity of the point source, explains the halo with a smaller angular size. By comparing the observational angle of the scattered halo photons with that predicted by different dust grain models, we are able to determine the normalized dust distance. With the delay times of the scattered halo photons, we can determine the point source distance, given a dust grain model. Alternatively we can discriminate between the dust grain models, given the point source distance.
One of the most recent discoveries of the INTEGRAL observatory is the existence of a previously unknown population of X-ray sources in the inner arms of the Galaxy. IGR J17544-2619, IGR J16465-4507 and XTE J1739-302 are among these sources. Although the nature of these systems is still unexplained, the investigations of the optical/NIR counterparts of the two last sources, combined with high energy data, have provided evidence of them being highly absorbed high mass X-ray binaries with blue supergiant secondaries and displaying fast X-ray transient behaviour. In this work we present our optical/NIR observations of IGR J17544-2619, aimed at identifying and characterizing its counterpart. We show that the source is a high mass X-ray binary at a distance of 2-4 kpc with a strongly absorbed O9Ib secondary, and discuss the nature of the system.
In this paper we report on a long multi-wavelength observational campaign of the supergiant fast X-ray transient prototype IGR J17544-2619. A 150 ks-long observation was carried out simultaneously with XMM-Newton and NuSTAR, catching the source in an initial faint X-ray state and then undergoing a bright X-ray outburst lasting about 7 ks. We studied the spectral variability during outburst and quiescence by using a thermal and bulk Comptonization model that is typically adopted to describe the X-ray spectral energy distribution of young pulsars in high mass X-ray binaries. Although the statistics of the collected X-ray data were relatively high we could neither confirm the presence of a cyclotron line in the broad-band spectrum of the source (0.5-40 keV), nor detect any of the previously reported tentative detection of the source spin period. The monitoring carried out with Swift/XRT during the same orbit of the system observed by XMM-Newton and NuSTAR revealed that the source remained in a low emission state for most of the time, in agreement with the known property of all supergiant fast X-ray transients being significantly sub-luminous compared to other supergiant X-ray binaries. Optical and infrared observations were carried out for a total of a few thousands of seconds during the quiescence state of the source detected by XMM-Newton and NuSTAR. The measured optical and infrared magnitudes were slightly lower than previous values reported in the literature, but compatible with the known micro-variability of supergiant stars. UV observations obtained with the UVOT telescope on-board Swift did not reveal significant changes in the magnitude of the source in this energy domain compared to previously reported values.
On 2003 September 17 INTEGRAL discovered a bright transient source 3 degrees from the Galactic Center, IGR J17544-2619. The field containing the transient was observed by XMM-Newton on 2003 March 17 and September 11 and 17. A bright source, at a posi tion consistent with the INTEGRAL location, was detected by the European Photon Imaging Camera (EPIC) during both September observations with mean 0.5-10 keV unabsorbed luminosities of 1.1x10^35 and 5.7x10^35 erg s-1 for an (assumed) distance of 8 kpc. The source was not detected in 2003 March, with a 0.5-10 keV luminosity of < 3.8x10^32 erg s-1. The September 11 and 17 EPIC spectra can be represented by a power-law model with photon indices of 2.25+/-0.15 and 1.42+/-0.17, respectively. Thus, the 0.5-10 keV spectrum hardens with increasing intensity. The low-energy absorption during both September observations is comparable to the interstellar value. The X-ray lightcurves for both September observations show energy dependent flaring which may be modeled by changes in either low-energy absorption or power-law index.
411 - Varun Bhalerao 2014
We present NuSTAR spectral and timing studies of the Supergiant Fast X-ray Transient (SFXT) IGR J17544-2619. The spectrum is well-described by a ~1 keV blackbody and a hard continuum component, as expected from an accreting X-ray pulsar. We detect a cyclotron line at 17 keV, confirming that the compact object in IGR J17544-2619 is indeed a neutron star. This is the first measurement of the magnetic field in a SFXT. The inferred magnetic field strength, B = (1.45 +/- 0.03) * 10^12 G * (1+z) is typical of neutron stars in X-ray binaries, and rules out a magnetar nature for the compact object. We do not find any significant pulsations in the source on time scales of 1-2000 s.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا