ترغب بنشر مسار تعليمي؟ اضغط هنا

Calibration of the EDELWEISS Cryogenic Heat-and-ionisation Germanium Detectors for Dark Matter Search

303   0   0.0 ( 0 )
 نشر من قبل Olivier Martineau
 تاريخ النشر 2003
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Several aspects of the analysis of the data obtained with the cryogenic heat-and-ionisation Ge detectors used by the EDELWEISS dark matter search experiment are presented. Their calibration, the determination of their energy threshold, fiducial volume and nuclear recoil acceptance are detailed.

قيم البحث

اقرأ أيضاً

The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published results. A reco il energy threshold of 13 keV or better was achieved with three 320g detectors working simultaneously over four months of stable operation. Limits on the spin-independent cross-section for the scattering of a WIMP on a nucleon are derived from an accumulated fiducial exposure of 62 kg.d.
The EDELWEISS experiment used in 2001 a 320g heat-and-ionization cryogenic Ge detector operated in a low-background environment in the Laboratoire Souterrain de Modane for direct WIMP detection. This detector presents an increase of more than 4 times the mass of previous detectors. Calibrations of this detector are used to determine its energy resolution and fiducial volume, and to optimize the detector design for the 1kg phase of the EDELWEISS-I experiment. Analysis of the calibrations and characteristics of a first series of 320g-detectors are presented.
Sensitive n-type and p-type germanium thermistors were fabricated by the melt doping technique and by the neutron transmutation doping (NTD) technique, respectively, aiming at a use for the cryogenic thermal detector, or bolometer of Tokyo dark matte r search programme. We report on the measurements of the sensitivities of these thermistors. In particular, the p-type thermistors are sensitive enough to scale up our existing prototype LiF bolometer and realize a multiple array of the bolometers with the total absorber mass of about 1,kg.
66 - E. Armengaud 2010
The EDELWEISS-II experiment uses cryogenic heat-and-ionization detectors in order to detect the rare interactions from possible WIMP dark matter particles on Germanium nuclei. Recently, new-generation detectors with an interleaved electrode geometry were developped and validated, enabling an outstanding rejection of gamma-rays and surface interactions. We present here preliminary results of a one-year WIMP search carried out with ten of such detectors in the Laboratoire Souterrain de Modane. A sensitivity to the spin-independent WIMP-nucleon cross-section of 5 times 10-8 pb was achieved using a 322 kg
The EDELWEISS-II collaboration has completed a direct search for WIMP dark matter with an array of ten 400-g cryogenic germanium detectors in operation at the Laboratoire Souterrain de Modane. The combined use of thermal phonon sensors and charge col lection electrodes with an interleaved geometry enables the efficient rejection of gamma-induced radioactivity as well as near-surface interactions. A total effective exposure of 384 kg.d has been achieved, mostly coming from fourteen months of continuous operation. Five nuclear recoil candidates are observed above 20 keV, while the estimated background is 3.0 events. The result is interpreted in terms of limits on the cross-section of spin-independent interactions of WIMPs and nucleons. A cross-section of 4.4x10^-8 pb is excluded at 90%CL for a WIMP mass of 85 GeV. New constraints are also set on models where the WIMP-nucleon scattering is inelastic.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا