ترغب بنشر مسار تعليمي؟ اضغط هنا

The Extended X-ray Halo of the Crab-like SNR G21.5-0.9

50   0   0.0 ( 0 )
 نشر من قبل Mr Nick Schurch
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English
 تأليف R.S. Warwick




اسأل ChatGPT حول البحث

Recent XMM-Newton observations reveal an extended (150) low-surface brightness X-ray halo in the supernova remnant G21.5-0.9. The near circular symmetry, the lack of any limb brightening and the non-thermal spectral form, all favour an interpretation of this outer halo as an extension of the central synchrotron nebula rather than as a shell formed by the supernova blast wave and ejecta. The X-ray spectrum of the nebula exhibits a marked spectral softening with radius, with the power-law spectral index varying from Gamma = 1.63 +/- 0.04 in the core to Gamma = 2.45 +/- 0.06 at the edge of the halo. Similar spectral trends are seen in other Crab-like remnants and reflect the impact of the synchrotron radiation losses on very high energy electrons as they diffuse out from the inner nebula. A preliminary timing analysis provides no evidence for any pulsed X-ray emission from the core of G21.5-0.9.

قيم البحث

اقرأ أيضاً

We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Gamma_1=1.74pm0.02$ and $Gamma_2=2.14pm0.01$ below and above the break at $7.1pm0.3$ keV, which is significantly lower than the NuSTAR result ($sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $sigma$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.
G21.5-0.9 is a plerionic supernova remnant (SNR) used as a calibration target for the Chandra X-ray telescope. The first observations found an extended halo surrounding the bright central pulsar wind nebula (PWN). A 2005 study discovered that this ha lo is limb-brightened and suggested the halo to be the missing SNR shell. In 2010 the spectrum of the limb-brightened shell was found to be dominated by non-thermal X-rays. In this study, we combine 15 years of Chandra observations comprising over 1~Msec of exposure time (796.1~ks with the Advanced CCD Imaging Spectrometer (ACIS) and 306.1~ks with the High Resolution Camera (HRC)) to provide the deepest-to-date imaging and spectroscopic study. The emission from the limb is primarily non-thermal and is described by a power-law model with a photon index $Gamma = 2.22 , (2.04-2.34)$, plus a weak thermal component characterized by a temperature $kT = 0.37, (0.20-0.64)$ keV and a low ionization timescale of $n_{e}t < 2.95 times 10^{10}$ cm$^{-3}$s. The northern knot located in the halo is best fitted with a two-component power-law + non-equilibrium ionization thermal model characterized by a temperature of 0.14 keV and an enhanced abundance of silicon, confirming its nature as ejecta. We revisit the spatially resolved spectral study of the PWN and find that its radial spectral profile can be explained by diffusion models. The best fit diffusion coefficient is $D sim 2.1times 10^{27}rm cm^2/s$ assuming a magnetic field $B =130 mu G$, which is consistent with recent 3D MHD simulation results.
We present new X-ray timing and spectral observations of PSR J1930+1852, the young energetic pulsar at the center of the non-thermal supernova remnant G54.1+0.3. Using data obtained with the Rossi X-ray Timing Explorer and Chandra X-ray observatories we have derived an updated timing ephemeris of the 136 ms pulsar spanning 6 years. During this interval, however, the period evolution shows significant variability from the best fit constant spin-down rate of $dot P = 7.5112(6) times 10^{-13}$ s s$^{-1}$, suggesting strong timing noise and/or glitch activity. The X-ray emission is highly pulsed ($71pm5%$ modulation) and is characterized by an asymmetric, broad profile ($sim 70%$ duty cycle) which is nearly twice the radio width. The spectrum of the pulsed emission is well fitted with an absorbed power law of photon index $Gamma = 1.2pm0.2$; this is marginally harder than that of the unpulsed component. The total 2-10 keV flux of the pulsar is $1.7 times 10^{-12}$ erg cm$^{-2}$ s$^{-1}$. These results confirm PSR J1930+1852 as a typical Crab-like pulsar.
The evolution of a pulsar wind nebula (PWN) depends on properties of the progenitor star, supernova, and surrounding environment. As some of these quantities are difficult to measure, reproducing the observed dynamical properties and spectral energy distribution (SED) with an evolutionary model is often the best approach in estimating their values. G21.5-0.9, powered by the pulsar J1833-1034, is a well observed PWN for which previous modeling efforts have struggled to reproduce the observed SED. In this study, we reanalyze archival infrared (IR; Herschel, Spitzer) and X-ray (Chandra, NuSTAR, Hitomi) observations. The similar morphology observed between IR line and continuum images of this source indicates that a significant portion of this emission is generated by surrounding dust and gas, and not synchrotron radiation from the PWN. Furthermore, we find the broadband X-ray spectrum of this source is best described by a series of power laws fit over distinct energy bands. For all X-ray detectors, we find significant softening and decreasing unabsorbed flux at higher energy bands. Our model for the evolution of a PWN is able to reproduce the properties of this source when the supernova ejecta has a low initial kinetic energy $E_{mathrm{sn}} approx 1.2 times 10^{50},mathrm{ergs}$ and the spectrum of particles injected into the PWN at the termination shock is softer at low energies. Lastly, our hydrodynamical modeling of the SNR can reproduce its morphology if there is a significant density increase of the ambient medium ${sim} 1.8$ pc north of the explosion center.
Context. The Crab nebula has been used as a celestial calibration source of the X-ray flux and spectral shape for many years by X-ray astronomy missions. However, the object is often too bright for current and future missions equipped with instrument s with improved sensitivity. Aims. We use G21.5-0.9 as a viable, fainter substitute to the Crab, which is another pulsar-wind nebula with a time-constant powerlaw spectrum with a flux of a few milli Crab in the X-ray band. Using this source, we conduct a cross-calibration study of the instruments onboard currently active observatories: Chandra ACIS, Suzaku XIS, Swift XRT, XMM-Newton EPIC (MOS and pn) for the soft-band, and INTEGRAL IBIS-ISGRI, RXTE PCA, and Suzaku HXD-PIN for the hard band. Methods. We extract spectra from all the instruments and fit them under the same astrophysical assumptions. We compare the spectral parameters of the G21.5-0.9 model: power-law photon index, H-equivalent column density of the interstellar photoelectric absorption, flux in the soft (2-8 keV) or hard (15-50 keV) energy band. Results. We identify the systematic differences in the best-fit parameter values unattributable to the statistical scatter of the data alone. We interpret these differences as due to residual cross-calibration problems. The differences can be as large as 20% and 9% for the soft-band flux and power-law index, respectively, and 46% for the hard-band flux. The results are plotted and tabulated as a useful reference for future calibration and scientific studies using multiple missions.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا