ترغب بنشر مسار تعليمي؟ اضغط هنا

GI2T/REGAIN spectro-interferometry with a new infrared beam combiner

77   0   0.0 ( 0 )
 نشر من قبل Karl-Heinz Hofmann
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English
 تأليف G. Weigelt




اسأل ChatGPT حول البحث

We have built an infrared beam combiner for the GI2T/REGAIN interferometer of the Observatoire de la Cote dAzur. The beam combiner allows us to record spectrally dispersed Michelson interference fringes in the near-infrared J-, H- or K-bands. The beam combiner has the advantage that Michelson interferograms can simultaneously be recorded in about 128 different spectral channels. The tilt of the spectrally dispersed fringes is a measure of the instantaneous optical path difference. We present the optical design of the beam combiner and GI2T/REGAIN observations of the Mira star R Cas with this beam combiner in the spectral range of 2.00 micron - 2.18 micron (observations on 22 and 25 August 1999; variability phase 0.08; V-magnitude approx. 6; seven baselines between 12m and 24m; reference stars Vega and Beta Peg). The spectrograph of the beam combiner consists of an anamorphotic cylindrical lens system, an image plane slit, and a grism. A system of digital signal processors calculates the ensemble average power spectrum of the spectrally dispersed Michelson interferograms and the instantaneous optical path difference error in real time. From the observed R Cas visibilities at baselines 12.0m, 13.8m and 13.9m, a 2.1 micron uniform-disk diameter of 25.3mas +/-3.3mas was derived. The unusually high visibility values at baselines >16m show that the stellar surface of R Cas is more complex than previously assumed. The visibility values at baselines >16m can be explained by high-contrast surface structure on the stellar surface of R Cas or other types of unexpected center-to-limb variations. The R Cas observations were compared with theoretical Mira star models yielding a linear Rosseland radius of 276Rsun +/-66Rsun and an effective temperature of 2685K+/-238K for R Cas at phase 0.08.

قيم البحث

اقرأ أيضاً

We present a compact setup based on a three-dimensional integrated optical component, allowing the mea- surement of spectrally resolved complex-visibilities for three channels of polychromatic light. We have tested a prototype of the component in R b and and showed that accurate complex visibilities could be retrieved over a bandwidth of 50 nm centered at 650 nm (resolution: R=130). Closure phase stability in the order of $lambda$/60 was achieved implying that the device could be used for spectro-interferometry imaging.
Integrated optic beam combiners offer many advantages over conventional bulk optic implementations for astronomical imaging. To date, integrated optic beam combiners have only been demonstrated at operating wavelengths below 4 microns. Operation in m id-infrared wavelength region, however, is highly desirable. In this paper, a theoretical design technique based on three coupled waveguides is developed to achieve fully achromatic, broadband, polarization-insensitive, lossless beam combining. This design may make it possible to achieve the very deep broadband nulls needed for exoplanet searching.
298 - Lucas Labadie 2011
Observations at mas-resolution scales and high dynamic range hold a central place in achieving, for instance, the spectroscopic characterization of exo-Earths or the detailed mapping of their protoplanetary disc birthplace. Ground or space-based mult i-aperture infrared interferometry is a promising technique to tackle these goals. But significant efforts still need to be undertaken to achieve a simplification of these instruments if we want to combine the light from a large number of telescopes. Integrated-optics appears as an alternative to the current conventional designs, especially if its use can be extended to a higher number of astronomical bands. This article reports for the first time the experimental demonstration of the feasibility of an integrated-optics approach to mid-infrared beam combination for single-mode stellar interferometry. We have fabricated a 2-telescope beam combiner prototype integrated on a substrate of chalcogenide glasses, a material transparent from 1 to 14 um. We have developed laboratory tools to characterize the modal properties and the interferometric capabilities of our device. We obtain fringes at 10 um and measure a mean contrast V=0.981 pm 0.001 with high repeatability over one week and high stability over 5h. We show experimentally - as well as on the basis of modeling considerations - that the component has a single-mode behavior at this wavelength, which is essential to achieve high-accuracy interferometry. From previous studies, the propagation losses are estimated to 0.5 dB/cm for such components. We also discuss possible issues that may impact the interferometric contrast. The IO beam combiner performs well at 10. We also anticipate the requirement of a better matching between the numerical apertures of the component and the (de)coupling optics to optimize the total throughput. The next step foreseen is the achievement of wide-band interferograms.
103 - Hsien-kai Hsiao 2009
Integrated-optic, astronomical, two-beam and three-beam, interferometric combiners have been designed and fabricated for operation in the L band (3 - 4 microns) for the first time. The devices have been realized in titanium-indiffused, x-cut lithium niobate substrates, and on-chip electro-optic fringe scanning has been demonstrated. White light fringes were produced in the laboratory using the two-beam combiner integrated with an on-chip Y-splitter.
Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post- processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q & U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا