ترغب بنشر مسار تعليمي؟ اضغط هنا

Analytical Inverter-Based Distributed Generator Model for Power Flow Analysis

65   0   0.0 ( 0 )
 نشر من قبل Naeem Turner-Bandele
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

Quantifying the impact of inverter-based distributed generation (DG) sources on power-flow distribution system cases is arduous. Existing distribution system tools predominately model distributed generation sources as either negative PQ loads or as a PV generator and then employed a PV-PQ switching algorithm to mimic Volt/VAR support. These models neglect the unique characteristics of inverter-based distributed generation sources, have scalability and convergence issues, and are ill-suited for increasing solar penetration scenarios. This work proposes an inverter-based DG model accounting for the inverters topology, sensing position, and control strategies. The model extends recently introduced analytical positive sequence generator models for three-phase studies. The use of circuit-simulation based heuristics help achieve robust convergence. Simulation of the PG&E prototypical feeders using a prototype solver demonstrate the models accuracy and efficacy.

قيم البحث

اقرأ أيضاً

We consider the problem of stability analysis for distribution grids with droop-controlled inverters and dynamic distribution power lines. The inverters are modeled as voltage sources with controllable frequency and amplitude. This problem is very ch allenging for large networks as numerical simulations and detailed eigenvalue analysis are impactical. Motivated by the above limitations, we present in this paper a systematic and computationally efficient framework for stability analysis of inverter-based distribution grids. To design our framework, we use tools from singular perturbation and Lyapunov theories. Interestingly, we show that stability of the fast dynamics of the power grid depends only on the voltage droop gains of the inverters while, stability of the slow dynamics, depends on both voltage and frequency droop gains. Finally, by leveraging these timescale separation properties, we derive sufficient conditions on the frequency and voltage droop gains of the inverters that warrant stability of the full system. We illustrate our theoretical results through a numerical example on the IEEE 13-bus distribution grid.
Distribution grid agents are obliged to exchange and disclose their states explicitly to neighboring regions to enable distributed optimal power flow dispatch. However, the states contain sensitive information of individual agents, such as voltage an d current measurements. These measurements can be inferred by adversaries, such as other participating agents or eavesdroppers. To address the issue, we propose a privacy-preserving distributed optimal power flow (OPF) algorithm based on partially homomorphic encryption (PHE). First of all, we exploit the alternating direction method of multipliers (ADMM) to solve the OPF in a distributed fashion. In this way, the dual update of ADMM can be encrypted by PHE. We further relax the augmented term of the primal update of ADMM with the $ell_1$-norm regularization. In addition, we transform the relaxed ADMM with the $ell_1$-norm regularization to a semidefinite program (SDP), and prove that this transformation is exact. The SDP can be solved locally with only the sign messages from neighboring agents, which preserves the privacy of the primal update. At last, we strictly prove the privacy preservation guarantee of the proposed algorithm. Numerical case studies validate the effectiveness and exactness of the proposed approach.
This paper presents a method for controlling the voltage of inverter-based Microgrids by proposing a new scale-free distributed cooperative controller. The communication network is modeled by a general time-varying graph which enhances the resilience of the proposed protocol against communication link failure, data packet loss, and fast plug and play operation in the presence of arbitrarily communication delays. The proposed scale-free distributed cooperative controller is independent of any information about the communication system and the size of the network (i.e., the number of distributed generators). The stability analysis of the proposed protocol is provided. The proposed method is simulated on the CIGRE medium voltage Microgrid test system. The simulation results demonstrate the feasibility of the proposed scale-free distributed nonlinear protocol for regulating the voltage of Microgrids in presence of communication failures, data packet loss, noise, and degradation.
97 - Shutang You 2021
A power system electromechanical wave propagates from the disturbance location to the rest of system, influencing various types of protections. In addition, since more power-electronics-interfaced generation and energy storage devices are being integ rated into power systems, electromechanical wave propagation speeds in the future power systems are likely to change accordingly. In this paper, GPS-synchronized measurement data from a wide-area synchrophasor measurement system FNET/GridEye are used to analyze the characteristics of electromechanical wave propagation in the U.S. Eastern Interconnection (EI) system. Afterwards, high levels of photovoltaic (PV) penetration are modeled in the EI to investigate the influences of a typical power-electronics--interfaced resource on the electromechanical wave propagation speed. The result shows a direct correlation between the local penetration level of inverter-based generation and the electromechanical wave propagation speed.
In Part I, a method for the Harmonic Power-Flow (HPF) study of three-phase power grids with Converter-Interfaced Distributed Energy Resources (CIDERs) is proposed. The method is based on generic and modular representations of the grid and the CIDERs, and explicitly accounts for coupling between harmonics. In Part II, the HPF method is validated. First, the applicability of the modeling framework is demonstrated on typical grid-forming and grid-following CIDERs. Then, the HPF method is implemented in Matlab and compared against time-domain simulations with Simulink. The accuracy of the models and the performance of the solution algorithm are assessed for individual resources and a modified version of the CIGRE low-voltage benchmark microgrid (i.e., with additional unbalanced components). The observed maximum errors are 6.3E-5 p.u. w.r.t. voltage magnitude, 1.3E-3 p.u. w.r.t. current magnitude, and 0.9 deg w.r.t. phase. Moreover, the scalability of the method is assessed w.r.t. the number of CIDERs and the maximum harmonic order ($leqslant$25). For the maximum problem size, the execution time of the HPF method is 6.52 sec, which is 5 times faster than the time-domain simulation. The convergence of the method is robust w.r.t. the choice of the initial point, and multiplicity of solutions has not been observed.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا