ترغب بنشر مسار تعليمي؟ اضغط هنا

A cavity entanglement and state swapping method to accelerate the search for axion dark matter

214   0   0.0 ( 0 )
 نشر من قبل Kelly Wurtz
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In cavity-based axion dark matter detectors, quantum noise remains a primary barrier to achieving the scan rate necessary for a comprehensive search of axion parameter space. Here we introduce a method of scan rate enhancement in which an axion-sensitive cavity is coupled to an auxiliary resonant circuit through simultaneous two-mode squeezing (entangling) and state swapping interactions. We show analytically that when combined, these interactions can amplify an axion signal before it becomes polluted by vacuum noise introduced by measurement. This internal amplification yields a wider bandwidth of axion sensitivity, increasing the rate at which the detector can search through frequency space. With interaction rates predicted by circuit simulations of this system, we show that this technique can increase the scan rate up to 15-fold relative to the scan rate of a detector limited by vacuum noise.



قيم البحث

اقرأ أيضاً

We propose using the storage ring EDM method to search for the axion dark matter induced EDM oscillation in nucleons. The method uses a combination of B and E-fields to produce a resonance between the $g-2$ spin precession frequency and the backgroun d axion field oscillation to greatly enhance sensitivity to it. An axion frequency range from $10^{-9}$ Hz to 100 MHz can in principle be scanned with high sensitivity, corresponding to an $f_a$ range of $10^{13} $ GeV $leq f_a leq 10^{30}$ GeV, the breakdown scale of the global symmetry generating the axion or axion like particles (ALPs).
82 - C. Boutan 2019
The $mu$eV axion is a well-motivated extension to the standard model. The Axion Dark Matter eXperiment (ADMX) collaboration seeks to discover this particle by looking for the resonant conversion of dark-matter axions to microwave photons in a strong magnetic field. In this Letter, we report results from a pathfinder experiment, the ADMX Sidecar, which is designed to pave the way for future, higher mass, searches. This testbed experiment lives inside of and operates in tandem with the main ADMX experiment. The Sidecar experiment excludes masses in three widely spaced frequency ranges (4202-4249, 5086-5799, and 7173-7203 MHz). In addition, Sidecar demonstrates the successful use of a piezoelectric actuator for cavity tuning. Finally, this publication is the first to report data measured using both the TM$_{010}$ and TM$_{020}$ modes.
Many experiments that interrogate fundamental theories require detectors whose sensitivities are limited by the laws of quantum mechanics. In cavity-based searches for axionic dark matter, vacuum fluctuations in the two quadratures of the cavity elec tromagnetic field limit the sensitivity to an axion-induced field. In an apparatus designed to partially mimic existing axion detectors, we demonstrate experimentally that such quantum limits can be overcome through the use of squeezed states. By preparing a microwave cavity in a squeezed state and measuring just the squeezed quadrature, we enhance the spectral scan rate by a factor of $2.12 pm 0.08$. This enhancement is in excellent quantitative agreement with a theoretical model accounting for both imperfect squeezing and measurement.
86 - N. Du , N. Force , R. Khatiwada 2018
This Letter reports results from a haloscope search for dark matter axions with masses between 2.66 and 2.81 $mu$eV. The search excludes the range of axion-photon couplings predicted by plausible models of the invisible axion. This unprecedented sens itivity is achieved by operating a large-volume haloscope at sub-kelvin temperatures, thereby reducing thermal noise as well as the excess noise from the ultra-low-noise SQUID amplifier used for the signal power readout. Ongoing searches will provide nearly definitive tests of the invisible axion model over a wide range of axion masses.
The microwave cavity experiment is the most sensitive way of looking for axions in the 0.1-10 GHz range, corresponding to masses of 0.5 - 40 $mu$eV. The particular challenge for frequencies greater than 5 GHz is designing a cavity with a large volume that contains a resonant mode that has a high form factor, a high quality factor, a wide dynamic range, and is free from intruder modes. For HAYSTAC, we have designed and constructed an optimized high frequency cavity with a tuning mechanism that preserves a high degree of rotational symmetry, critical to maximizing its figure of merit. This cavity covers an important frequency range according to recent theoretical estimates for the axion mass, 5.5 - 7.4 GHz, and the design appears extendable to higher frequencies as well. This paper will discuss key design and construction details of the cavity, present a summary of the design evolution, and alert practitioners of potentially unfruitful avenues for future work.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا