ترغب بنشر مسار تعليمي؟ اضغط هنا

Two-dimensional time- and space-resolved diagnostic method for integrated implosion process

83   0   0.0 ( 0 )
 نشر من قبل Shi-Jian Li
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

To precisely measure and evaluate X-ray generation and evolution in a hohlraum during an implosion process, we present a two-dimensional (2D) time- and space-resolved diagnostic method by combining a compressed ultrafast photography (CUP) system and a simplified version of space-resolving flux detector (SSRFD). Numerical experiment results showed that the reconstruction quality of the conventional CUP significantly improved owing to the addition of the external SSRFD, especially when a coded mask with a large pixel size was used in the CUP. Further, the performance of the CUP cooperation with the SSRFD was better than that of adding an external charge-coupled device or streak camera. Compared with existing ultrafast imaging techniques in laser fusion, the proposed method has a prominent advantage of measuring the 2D evolution of implosion by combining high temporal resolution of streak camera and high spatial resolution of SSRFD; moreover, it can provide guidance for designing diagnostic experiments in laser fusion research.

قيم البحث

اقرأ أيضاً

The spatial distribution of magnetic fields that are generated by the electromagnetic flux compression technique is investigated, with emphasis on the dynamical processes of an imploding liner. By comparing with the results of computer simulations, w e found that the non-uniform implosion of a liner is important in order to explain the magnetic fields distribution during the liners implosion. In addition, our results suggest that the initial inwards compressing spool-like motion of the liner subsequently turns out to be outwards stretching barrel-like motion along the magnetic field axis.
We have developed an application of a one-dimensional micro-strip detector for capturing x-ray diffraction data in pulsed magnetic fields. This detector consists of a large array of 50 mu m-wide Si strips with a full-frame read out at 20 kHz. Its use substantially improves data-collection efficiency and quality as compared to point detectors, because diffraction signals are recorded along an arc in reciprocal space in a time-resolved manner. By synchronizing with pulsed fields, the entire field dependence of a two-dimensional swath of reciprocal space may be determined using a small number of field pulses.
In this work, we develop two spectroscopic diagnostic methods to derive the peak reduced electric field in Transient Luminous Events (TLEs) from their optical signals. These methods could be used to analyze the optical signature of TLEs reported by s pacecraft such as ASIM (ESA) and the future TARANIS (CNES). As a first validation of these methods, we apply them to the predicted (synthetic) optical signatures of halos and elves, two type of TLEs, obtained from electrodynamical models. This procedure allows us to compare the inferred value of the peak reduced electric field with the value computed by halo and elve models. Afterward, we apply both methods to the analysis of optical signatures of elves and halos reported by GLIMS (JAXA) and ISUAL (NSPO) spacecraft, respectively. We conclude that the best emission ratios to estimate the maximum reduced electric field in halos and elves are the ratio of the Second Positive System (SPS) of N$_2$ to First Negative System (FNS) of N$_2^+$, the First Positive System (FPS) of N$_2$ to FNS of N$_2^+$ and the Lyman-Birge-Hopfield (LBH) band of N$_2$ to FNS of N$_2^+$. In the case of reduced electric fields below 150~Td, we found that the ratio of the SPS of N$_2$ to FPS of N$_2$ can also be used to reasonably estimate the value of the field. Finally, we show that the reported optical signals from elves can be treated following an inversion method in order to estimate some of the characteristics of the parent lightning.
203 - X. Qin , Z. Shi , Y. Xie 2017
A highly integrated, high performance, and re-configurable device, which is designed for the Nitrogen-Vacancy center based quantum applications, is reported. The digital compartment of the device is fully implemented in a Field-Programmable-Gate- Arr ay. The digital compartment is designed to manage the multi-function digital waveform generation and the Time-to-Digital-Convertors. The device provides two Arbitrary-Waveform-Generator channels which operate at a 1 Gsps sampling rate with a maximum bandwidth of 500 MHz. There are twelve pulse channels integrated in the device with a 50 ps time resolution in both duration and delay. The pulse channels operate with the 3.3 V Transistor-Transistor logic. The FPGA-based Timeto- Digital-Convertor provides a 23-ps time measurement precision. A data accumulation module, which can record the input count rate and the distributions of the time measurement, is also available. A Digital-to-Analog-Convertor board is implemented as the analog compartment, which converts the digital waveforms to analog signals with 500 MHz low-pass-filters. All the input and output channels of the device are equipped with 50 Sub-Miniature version A termination. The hardware design is modularized thus it can be easily upgraded with compatible components. The device is suitable to be applied in the quantum technologies based on the N-V centers, as well as in other quantum solid state systems, such as quantum dots, phosphorus doped in silicon and defect spins in silicon carbide.
To indirectly evaluate the asymmetry of the radiation drive under limited measurement conditions in inertial confinement fusion research, we have proposed an integral method to approximate the three-dimensional self-radiation distribution of the comp ressed plasma core using only four pinhole images from a single laser entrance hole at a maximum projection angle of 10{deg}. The simultaneous algebraic reconstruction technique (SART) that uses spatial constraints provided by the prior structural information and the central pinhole image is utilized in the simulation. The simulation results showed that the normalized mean square deviation between the original distribution and reconstruction results of the central radiation area of the simulated cavity was 0.4401, and the structural similarity of the cavity radiation distribution was 0.5566. Meanwhile, using more diagnostic holes could achieve better structural similarity and lower reconstruction error. In addition, the results indicated that our new proposed method could reconstruct the distribution of a compressed plasma core in a vacuum hohlraum with high accuracy.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا