ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurements of branching fractions and asymmetry parameters of $Xi^0_cto Lambdabar K^{*0}$, $Xi^0_cto Sigma^0bar K^{*0}$, and $Xi^0_cto Sigma^+K^{*-}$ decays at Belle

153   0   0.0 ( 0 )
 نشر من قبل Chengping Shen
 تاريخ النشر 2021
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

Using a data sample of 980 fb$^{-1}$ collected with the Belle detector at the KEKB asymmetric-energy $e^+e^-$ collider, we study the processes of $Xi^0_cto Lambdabar K^{*0}$, $Xi^0_cto Sigma^0bar K^{*0}$, and $Xi^0_cto Sigma^+K^{*-}$ for the first time. The relative branching ratios to the normalization mode of $Xi^0_ctoXi^-pi^+$ are measured to be $${cal B}(Xi^0_cto Lambdabar K^{*0})/{cal B}(xicto Xi^-pi^+)=0.18pm0.02({rm stat.})pm0.01({rm syst.}),$$ $${cal B}(Xi^0_cto Sigma^0bar K^{*0})/{cal B}(xicto Xi^-pi^+)=0.69pm0.03({rm stat.})pm0.03({rm syst.}),$$ $${cal B}(Xi^0_cto Sigma^+K^{*-})/{cal B}(xicto Xi^-pi^+)=0.34pm0.06({rm stat.})pm0.02({rm syst.}),$$ where the uncertainties are statistical and systematic, respectively. We obtain %measure the branching fractions of $Xi^0_cto Lambdabar K^{*0}$, $Xi^0_cto Sigma^0bar K^{*0}$, and $Xi^0_cto Sigma^+K^{*-}$ to be $${cal B}(Xi^0_cto Lambdabar K^{*0})=(3.3pm0.3({rm stat.})pm0.2({rm syst.})pm1.0({rm ref.}))times10^{-3},$$ $${cal B}(Xi^0_cto Sigma^0bar K^{*0})=(12.4pm0.5({rm stat.})pm0.5({rm syst.})pm3.6({rm ref.}))times10^{-3},$$ $${cal B}(Xi^0_cto Sigma^+K^{*-})=(6.1pm1.0({rm stat.})pm0.4({rm syst.})pm1.8({rm ref.}))times10^{-3},$$ where the uncertainties are statistical, systematic, and from ${cal B}(xic to Xi^-pi^+)$, respectively. The asymmetry parameters $alpha(Xi^0_cto Lambdabar K^{*0})$ and $alpha(Xi^0_cto Sigma^+K^{*-})$ are $0.15pm0.22({rm stat.})pm0.04({rm syst.})$ and $-0.52pm0.30({rm stat.})pm0.02({rm syst.})$, respectively, where the uncertainties are statistical followed by systematic.



قيم البحث

اقرأ أيضاً

Using data samples of 89.5 and 711 fb$^{-1}$ recorded at energies of $sqrt{s}=10.52$ and $10.58$ GeV, respectively, with the Belle detector at the KEKB $e^+e^-$ collider, we report measurements of branching fractions of semileptonic decays $Xi_{c}^{0 } to Xi^{-} ell^{+} u_{ell}$ ($ell=e$ or $mu$) and the $CP$-asymmetry parameter of $Xi_{c}^{0} to Xi^{-} pi^{+}$ decay. The branching fractions are measured to be ${cal B}(Xi_{c}^{0} to Xi^{-} e^{+} u_{e})=(1.31 pm 0.04 pm 0.07 pm 0.38)%$ and ${cal B}(Xi_{c}^{0} to Xi^{-} mu^{+} u_{mu})=(1.27 pm 0.06 pm 0.10 pm 0.37)%$, and the decay parameter $alpha_{Xipi}$ is measured to be $0.63 pm 0.03 pm 0.01$ with much improved precision compared to the current world average. The corresponding ratio ${cal B}(Xi_{c}^{0} to Xi^{-} e^{+} u_{e})/{cal B}(Xi_{c}^{0} to Xi^{-} mu^{+} u_{mu})$ is $1.03 pm 0.05pm 0.07$, which is consistent with the expectation of lepton flavor universality. The first measured asymmetry parameter ${cal A}_{CP} = (alpha_{Xi^{-}pi^{+}} + alpha_{bar{Xi}^{+}pi^{-}})/(alpha_{Xi^{-}pi^{+}} - alpha_{bar{Xi}^{+}pi^{-}}) = 0.024 pm 0.052 pm 0.014$ is found to be consistent with zero. The first and the second uncertainties above are statistical and systematic, respectively, while the third ones arise due to the uncertainty of the $Xi_{c}^{0} to Xi^{-} pi^+$ branching fraction.
Using the entire data sample of $980$ $fb^{-1}$ integrated luminosity collected with the Belle detector at the KEKB asymmetric-energy $e^{+}e^{-}$ collider, we present an amplitude analysis measuring the branching fractions of the Cabibbo-allowed, $W $-exchange resonant decay $Xi_{c}^{0} rightarrow Xi^{0} phi (to K^+ K^-)$ with a polarized $phi$ and the non-resonant decay via a direct process $Xi_{c}^{0} rightarrow Xi^{0} K^+ K^-$. We present these measurements, relative to the normalization mode $Xi^{-}pi^{+}$, and find branching ratios $frac{mathcal{B}(Xi_{c}^{0} rightarrow Xi^{0} phi (rightarrow K^{+}K^{-}))}{mathcal{B}(Xi_{c}^{0} rightarrow Xi^{-} pi^{+})} = 0.036 pm 0.004 (stat.) pm 0.002 (syst.)$ and $frac{mathcal{B}(Xi_{c}^{0} rightarrow Xi^{0} K^{+} K^{-})}{mathcal{B}(Xi_{c}^{0} rightarrow Xi^{-} pi^{+})} = 0.039 pm 0.004 (stat.) pm 0.002 (syst.)$ which suggest that only minor cusping peaks occur in the combinatorial background of $Omega^{*-} to Xi^{0}K^{-}$ due to these $Xi_{c}^{0}$ decays.
We report the first observation of the doubly-strange baryon $Xi(1620)^0$ in its decay to $Xi^-pi^+$ via $Xi_c^+ rightarrow Xi^- pi^+ pi^+$ decays based on a $980,{rm fb}^{-1}$ data sample collected with the Belle detector at the KEKB asymmetric-ener gy $e^+ e^-$ collider. The mass and width are measured to be 1610.4 $pm$ 6.0 (stat) $^{+5.9}_{-3.5}$ (syst)~MeV$/c^2$ and 59.9 $pm$ 4.8 (stat) $^{+2.8}_{-3.0}$ (syst)~MeV, respectively. We obtain 4.0$sigma$ evidence of the $Xi(1690)^0$ with the same data sample. These results shed light on the structure of hyperon resonances with strangeness $S=-2$.
Using $(448.1pm2.9)times 10^{6}$ $psi(3686)$ events collected with the BESIII detector and a single-baryon tagging technique, we present the first observation of the decays $psi(3686)toXi(1530)^{0}bar{Xi}(1530)^{0}$ and $Xi(1530)^{0}bar{Xi}^0$. The b ranching fractions are measured to be ${cal{B}}(psi(3686)toXi(1530)^{0}bar{Xi}(1530)^{0}) = (6.77pm0.14pm0.39)times10^{-5}$ and ${cal{B}}(psi(3686)toXi(1530)^{0}bar{Xi}^{0}) = (0.53pm0.04pm0.03)times10^{-5}$. Here, the first and second uncertainties are statistical and systematic, respectively. In addition, the parameter associated with the angular distribution for the decay $psi(3686)toXi(1530)^{0}bar{Xi}(1530)^0$ is determined to be $alpha = 0.32pm0.19pm0.07$, in agreement with theoretical predictions within one standard deviation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا