ترغب بنشر مسار تعليمي؟ اضغط هنا

Optimal Positioning of PMUs for Fault Detection and Localization in Active Distribution Networks

85   0   0.0 ( 0 )
 نشر من قبل Francesco Conte
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper considers the problem of fault detection and localization in active distribution networks using PMUs. The proposed algorithm consists in computing a set of weighted least squares state estimates whose results are used to detect, characterize and localize the occurrence of a fault. Moreover, a criteria to minimize the number of PMUs required to correctly perform the proposed algorithm is defined. Such a criteria, based on system observability conditions, allows the design of an optimization problem to set the positions of PMUs along the grid, in order to get the desired fault localization resolution. The performances of the strategy are tested via simulations on a benchmark distribution system.

قيم البحث

اقرأ أيضاً

This paper presents a method for the optimal siting and sizing of energy storage systems (ESSs) in active distribution networks (ADNs) to achieve their dispatchability. The problem formulation accounts for the uncertainty inherent to the stochastic n ature of distributed energy sources and loads. Thanks to the operation of ESSs, the main optimization objective is to minimize the dispatch error, which accounts for the mismatch between the realization and prediction of the power profile at the ADN connecting point to the upper layer grid, while respecting the grid voltages and ampacity constraints. The proposed formulation relies on the so-called Augmented Relaxed Optimal Power Flow (AR-OPF) method: it expresses a convex full AC optimal power flow, which is proven to provide a global optimal and exact solution in the case of radial power grids. The AR-OPF is coupled with the proposed dispatching control resulting in a two-level optimization problem. In the first block, the site and size of the ESSs are decided along with the level of dispatchability that the ADN can achieve. Then, in the second block, the adequacy of the ESS allocations and the feasibility of the grid operating points are verified over operating scenarios using the Benders decomposition technique. Consequently, the optimal size and site of the ESSs are adjusted. To validate the proposed method, simulations are conducted on a real Swiss ADN hosting a large amount of stochastic Photovoltaic (PV) generation.
Ellipsoids are a common representation for reachability analysis because they are closed under affine maps and allow conservative approximation of Minkowski sums; this enables one to incorporate uncertainty and linearization error in a dynamical syst em by exapnding the size of the reachable set. Zonotopes, a type of symmetric, convex polytope, are similarly frequently used due to efficient numerical implementation of affine maps and exact Minkowski sums. Both of these representations also enable efficient, convex collision detection for fault detection or formal verification tasks, wherein one checks if the reachable set of a system collides (i.e., intersects) with an unsafe set. However, both representations often result in conservative representations for reachable sets of arbitrary systems, and neither is closed under intersection. Recently, constrained zonotopes and constrained polynomial zonotopes have been shown to overcome some of these conservatism challenges, and are closed under intersection. However, constrained zonotopes can not represent shapes with smooth boundaries such as ellipsoids, and constrained polynomial zonotopes can require solving a non-convex program for collision checking (i.e., fault detection). This paper introduces ellipsotopes, a set representation that is closed under affine maps, Minkowski sums, and intersections. Ellipsotopes combine the advantages of ellipsoids and zonotopes, and enable convex collision checking at the expense of more conservative reachable sets than constrained polynomial zonotopes. The utility of this representation is demonstrated on several examples.
This paper proposes a joint input and state dynamic estimation scheme for power networks in microgrids and active distribution systems with unknown inputs. The conventional dynamic state estimation of power networks in the transmission system relies on the forecasting methods to obtain the state-transition model of state variables. However, under highly dynamic conditions in the operation of microgrids and active distribution networks, this approach may become ineffective as the forecasting accuracy is not guaranteed. To overcome such drawbacks, this paper employs the power networks model derived from the physical equations of branch currents. Specifically, the power network model is a linear state-space model, in which the state vector consists of branch currents, and the input vector consists of bus voltages. To estimate both state and input variables, we propose linear Kalman-based dynamic filtering algorithms in batch-mode regression form, considering the cross-correlation between states and inputs. For the scalability of the proposed scheme, the distributed implementation is also presented. Complementarily, the predicted state and input vectors are leveraged for bad data detection. Results carried out on a 13-bus microgrid system in real-time Opal-RT platform demonstrate the effectiveness of the proposed method in comparison with the traditional weighted least square and tracking state estimation methods.
Feeder identification is indispensable for distribution networks to locate faults at a specific feeder, especially when measuring de-vices are insufficient for precise locations. For the high imped-ance fault (HIF), the feeder identification is much more compli-cated and related approaches are still in the early stage. This paper thoroughly and theoretically reveals the features of dif-ferent feeders when a HIF happens at the resonant grounded neutral (RGN) network, which is the most challenging condition for feeder identification. Firstly, the diversity of nonlinearity existing in HIFs is explained from the aspect of energy. Then, the differences of nonlinearities of zero-sequence currents between healthy and faulty feeders are deduced theoretically. Variations of the detuning index and damping ratio that exist in industries are both considered. Afterward, these theoretical conclusions are verified by the HIF cases experimented in a real 10kV system. Finally, based on the theories, we discuss about why the existing approaches are not reliable enough, and suggest some improve-ments.
Closed-loop control systems employ continuous sensing and actuation to maintain controlled variables within preset bounds and achieve the desired system output. Intentional disturbances in the system, such as in the case of cyberattacks, can compromi se reachability of control goals, and in several cases jeopardize safety. The increasing connectivity and exposure of networked control to external networks has enabled attackers to compromise these systems by exploiting security vulnerabilities. Attacks against safety-critical control loops can not only drive the system over a trajectory different from the desired, but also cause fatal consequences to humans. In this paper we present a physics-based Intrusion Detection System (IDS) aimed at increasing the security in control systems. In addition to conventional process state estimation for intrusion detection, since the controller cannot be trusted, we introduce a controller state estimator. Additionally, we make our detector context-aware by utilizing sensor measurements from other control loops, which allows to distinguish and characterize disturbances from attacks. We introduce adaptive thresholding and adaptive filtering as means to achieve context-awareness. Together, these methodologies allow detection and localization of attacks in closed-loop controls. Finally, we demonstrate feasibility of the approach by mounting a series of attacks against a networked Direct Current (DC) motor closed-loop speed control deployed on an ECU testbed, as well as on a simulated automated lane keeping system. Among other application domains, this set of approaches is key to support security in automotive systems, and ultimately increase road and passenger safety.