ترغب بنشر مسار تعليمي؟ اضغط هنا

A bottom-up quantification of flexibility potential from the thermal energy storage in electric space heating

319   0   0.0 ( 0 )
 نشر من قبل Lars Herre
 تاريخ النشر 2021
والبحث باللغة English




اسأل ChatGPT حول البحث

Non-generating resources such as thermostatically controlled loads (TCLs) can arbitrage energy prices and provide balancing reserves when aggregated due to their thermal energy storage capacity. Based on a performed survey of Swedish single- and two-family dwellings with electric heating, this paper quantifies the potential of TCLs to provide reserves to the power system in Sweden. To this end, dwellings with heat pumps and direct electric heaters are modeled as thermal energy storage equivalents that can be included in a linear two-stage problem formulation. We approach the operational flexibility of the TCLs by modeling a risk-averse aggregator that controls decentralized TCLs and aims to maximize its own profit. The results show a potential of 2 GW/0.1Hz averaged over a year, and up to 6.4 GW/0.1Hz peak capacity. Based on a sensitivity analysis we derive policy implications regarding market timing and activation signal.

قيم البحث

اقرأ أيضاً

In this paper, a method to evaluate the flexibility of aggregates of domestic electric water heaters is proposed and applied to the Italian case. Flexibility is defined as the capability of the aggregate to vary its power demand for a given time inte rval. The evaluation method consists of a Monte Carlo analysis, that uses the thermal model of electric water heaters and a proper elaboration of the external inputs, such as ambient and cold water temperatures, and hot water demand. The case of large aggregates defined along the Italian territory has been studied showing the dependence of flexibility on seasons and on time.
136 - Likai Liu , Zechun Hu , Jian Ning 2021
The rapid development of renewable energy has increased the peak to valley difference of the netload, making the netload following being a new challenge to the power system. Electric boiler with thermal storage (EBTS) occupies a non-negligible part o f the load in the winter season in Northern China. EBTS operation optimization can not only save its own energy cost but also reduce the peak shaving and valley filling pressure of the system. To this end, the operation optimization of EBTS for providing the power balancing service is studied in this paper, which mainly includes three parts: First, the joint probability distribution between the predicted and actual temperatures is built by utilizing the Copula theory; Secondly, the actual temperatures are sampled based on the predicted temperatures of the next day, and the scenario set is generated by clustering these samples, where K-means clustering method are used; Thirdly, the stochastic operation optimization model of EBTS considering the uncertainty of outdoor temperature is constructed. Through the case study, it is found that the proposed method can save the total operation cost of the EBTS compared with the deterministic EBTS operation optimization model.
Distributed renewable energy systems are now widely installed in many buildings, transforming the buildings into electricity prosumers. Existing studies have developed some advanced building side controls that enable renewable energy sharing and that aim to optimise building-cluster-level performance via regulating the energy storage charging/ discharging. However, the flexible demand shifting ability of electric vehicles is not considered in these building side controls. For instance, the electric vehicle charging will usually start once they are plugged into charging stations. But, in such charging period the renewable generation may be insufficient to cover the EV charging load, leading to grid electricity imports. Consequently, the building-cluster-level performance is not optimised. Therefore, this study proposes a coordinated control of building prosumers for improving the cluster-level performance, by making use of energy sharing and storage capability of electricity batteries in both buildings and EVs. An EV charging/discharging model is first developed. Then, based on the predicted future 24h electricity demand and renewable generation data, the coordinated control first considers the whole building cluster as one integrated building and optimises its operation as well as the EV charging/discharging using genetic algorithm. Next, the operation of individual buildings in the future 24h is coordinated using nonlinear programming. For validation, the developed control has been tested on a real building cluster in Ludvika, Sweden. The study results show that the developed control can increase the cluster-level daily renewable self-consumption rate by 19% and meanwhile reduce the daily electricity bills by 36% compared with the conventional controls.
Massive adoptions of combined heat and power (CHP) units necessitate the coordinated operation of power system and district heating system (DHS). Exploiting the reconfigurable property of district heating networks (DHNs) provides a cost-effective sol ution to enhance the flexibility of the power system by redistributing heat loads in DHS. In this paper, a unit commitment considering combined electricity and reconfigurable heating network (UC-CERHN) is proposed to coordinate the day-ahead scheduling of power system and DHS. The DHS is formulated as a nonlinear and mixed-integer model with considering the reconfigurable DHN. Also, an auxiliary energy flow variable is introduced in the formed DHS model to make the commitment problem tractable, where the computational burdens are significantly reduced. Extensive case studies are presented to validate the effectiveness of the approximated model and illustrate the potential benefits of the proposed method with respect to congestion management and wind power accommodation. (Corresponding author:Hongbin Sun)
74 - Yue Shen , Maxim Bichuch , 2020
This work seeks to quantify the benefits of using energy storage toward the reduction of the energy generation cost of a power system. A two-fold optimization framework is provided where the first optimization problem seeks to find the optimal storag e schedule that minimizes operational costs. Since the operational cost depends on the storage capacity, a second optimization problem is then formulated with the aim of finding the optimal storage capacity to be deployed. Although, in general, these problems are difficult to solve, we provide a lower bound on the cost savings for a parametrized family of demand profiles. The optimization framework is numerically illustrated using real-world demand data from ISO New England. Numerical results show that energy storage can reduce energy generation costs by at least 2.5 %.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا