ترغب بنشر مسار تعليمي؟ اضغط هنا

A low phase noise microwave source for high performance CPT Rb atomic clock

117   0   0.0 ( 0 )
 نشر من قبل Enxue Yun
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Phase noise of the frequency synthesizer is one of the main limitations to the short-term stability of microwave atomic clocks. In this work, we demonstrated a low-noise, simple-architecture microwave frequency synthesizer for a coherent population trapping (CPT) clock. The synthesizer is mainly composed of a 100 MHz oven controlled crystal oscillator (OCXO), a microwave comb generator and a direct digital synthesizer (DDS). The absolute phase noises of 3.417 GHz signal are measured to be -55 dBc/Hz, -81 dBc/Hz, -111 dBc/Hz and -134 dBc/Hz, respectively, for 1 Hz, 10 Hz, 100 Hz and 1 kHz offset frequencies, which shows only 1 dB deterioration at the second harmonic of the modulation frequency of the atomic clock. The estimated frequency stability of intermodulation effect is 4.7*10^{-14} at 1s averaging time, which is about half order of magnitude lower than that of the state-of-the-art CPT Rb clock. Our work offers an alternative microwave synthesizer for high-performance CPT Rb atomic clock.

قيم البحث

اقرأ أيضاً

We demonstrate an easy to manufacture, 25 mm long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a cavity ge ometry that improves the thermal noise limit at room temperature, we observe a laser phase noise that is nearly thermal noise limited for three frequency decades (1 Hz to 1 kHz offset) and supports 10 GHz generation with phase noise near -100 dBc/Hz at 1 Hz offset and <-173 dBc/Hz for all offsets >600 Hz. The fractional frequency stability reaches $2times10^{-15}$ at 0.1 s of averaging.
Two nominally identical ultra-stable cryogenic microwave oscillators are compared. Each incorporates a dielectric-sapphire resonator cooled to near 6 K in an ultra-low vibration cryostat using a low-vibration pulse-tube cryocooler. The phase noise fo r a single oscillator is measured at -105 dBc/Hz at 1 Hz offset on the 11.2 GHz carrier. The oscillator fractional frequency stability is characterized in terms of Allan deviation by 5.3 x 10^-16 tau^-1/2 + 9 x 10^-17 for integration times 0.1 s < tau < 1000 s and is limited by a flicker frequency noise floor below 1 x 10^-16. This result is better than any other microwave source even those generated from an optical comb phase-locked to a room temperature ultra-stable optical cavity.
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We rep ort on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator. The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time. The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 tau ^-1 + 3.6 x 10^-15 tau ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 tau ^-1/2 + 3 x 10^-16, respectively, for 1 s < tau < 10^4 s. We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.
We demonstrate photon noise limited performance in both phase and amplitude readout in microwave kinetic inductance detectors (MKIDs) consisting of NbTiN and Al, down to 100 fW of optical power. We simulate the far field beam pattern of the lens-ante nna system used to couple radiation into the MKID and derive an aperture efficiency of 75%. This is close to the theoretical maximum of 80% for a single-moded detector. The beam patterns are verified by a detailed analysis of the optical coupling within our measurement setup.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique (PPOP) in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impa ct of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by $1/(2T_R)$, with $T_R$ the free-evolution time, for short values of $T_R$. The clock demonstrates a short-term fractional frequency stability at the level of $2.3 times 10^{-13}~tau^{-1/2}$ up to 100 seconds averaging time, mainly limited by the laser AM noise. Comparable performances are obtained in the conventional continuous (CW) regime, if use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of $T_R$. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا