ترغب بنشر مسار تعليمي؟ اضغط هنا

Spectrometer Using superconductor MIxer Receiver (SUMIRE) for Laboratory Submillimeter Spectroscopy

82   0   0.0 ( 0 )
 نشر من قبل Yoshimasa Watanabe
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Recent spectroscopic observations by sensitive radio telescopes require accurate molecular spectral line frequencies to identify molecular species in a forest of lines detected. To measure rest frequencies of molecular spectral lines in the laboratory, an emission-type millimeter and submillimeter-wave spectrometer utilizing state-of-the-art radio-astronomical technologies is developed. The spectrometer is equipped with a 200 cm glass cylinder cell, a two sideband (2SB) Superconductor-Insulator-Superconductor (SIS) receiver in the 230 GHz band, and wide-band auto-correlation digital spectrometers. By using the four 2.5 GHz digital spectrometers, a total instantaneous bandwidth of the 2SB SIS receiver of 8 GHz can be covered with a frequency resolution of 88.5 kHz. Spectroscopic measurements of CH$_3$CN and HDO are carried out in the 230 GHz band so as to examine frequency accuracy, stability, sensitivity, as well as intensity calibration accuracy of our system. As for the result of CH$_3$CN, we confirm that the frequency accuracy for lines detected with sufficient signal to noise ratio is better than 1 kHz, when the high resolution spectrometer having a channel resolution of 17.7 kHz is used. In addition, we demonstrate the capability of this system by spectral scan measurement of CH$_3$OH from 216 GHz to 264 GHz. We assign 242 transitions of CH$_3$OH, 51 transitions of $^{13}$CH$_3$OH, and 21 unidentified emission lines for 295 detected lines. Consequently, our spectrometer demonstrates sufficient sensitivity, spectral resolution, and frequency accuracy for in-situ experimental-based rest frequency measurements of spectral lines on various molecular species.

قيم البحث

اقرأ أيضاً

We present a conceptual framework of planar SIS mixer array receivers and the studies on the required techniques. This concept features membrane-based on-chip waveguide probes and a quasi-two-dimensional local-oscillator distribution waveguide networ k. This concept allows sophisticated functions, such as dual-polarization, balanced mixing and sideband separation, easily implemented with the SIS mixer array in the same planar circuit. We have developed a single-pixel prototype receiver by implementing the concept in the design. Initial measurement results show good evidences that support the feasibility of the concept.
88 - Volker Crede 2011
Baryons are complex systems of confined quarks and gluons and exhibit the characteristic spectra of excited states. The systematics of the baryon excitation spectrum is important to our understanding of the effective degrees of freedom underlying nuc leon matter. High-energy electrons and photons are a remarkably clean probe of hadronic matter, providing a microscope for examining the nucleon and the strong nuclear force. Current experimental efforts with the CLAS spectrometer at Jefferson Laboratory utilize highly-polarized frozen-spin targets in combination with polarized photon beams. The status of the recent double-polarization experiments and some preliminary results are discussed in this contribution.
The Atacama Large Millimeter/submillimeter Array(ALMA) Band 1 receiver covers the 35-50 GHz frequency band. Development of prototype receivers, including the key components and subsystems has been completed and two sets of prototype receivers were fu lly tested. We will provide an overview of the ALMA Band 1 science goals, and its requirements and design for use on the ALMA. The receiver development status will also be discussed and the infrastructure, integration, evaluation of fully-assembled band 1 receiver system will be covered. Finally, a discussion of the technical and management challenges encountered will be presented.
In this study, we designed and experimentally evaluated a series-connected array of superconductor-insulator-superconductor (SIS) junctions in the 100-GHz band mixer for the multi-beam receiver FOREST on the Nobeyama 45-m millimeter-wave telescope. T he construction of the junction chip comprised a waveguide probe antenna, impedance matching circuit, SIS array junction, and choke filter, which were made from a superconducting niobium planar circuit on a quartz substrate. The multi-stage impedance matching circuit between the feed point and the SIS junction was designed as a capacitively loaded transmission line, and it comprised two sections with high (~90 Ohm) and low (~10 Ohm) characteristic impedance transmission lines. The structure of this tuning line was simple and easy to fabricate, and the feed impedance matched with the SIS junction in a wide frequency range. The signal coupling efficiency was more than 92% and the expected receiver noise temperature was approximately two times the quantum limit for 75-125 GHz based on quantum theory. The array junction devices with 3-6 connected junctions were fabricated and we measured their performance in terms of the receiver noise temperature and gain compression in the laboratory. We successfully developed an array junction device with a receiver noise temperature of ~15-30 K and confirmed that the improvement in the saturation power corresponded to the number of junctions. The newly developed array junction mixer was installed in the FOREST receiver and it successfully detected the 12CO (J = 1-0) molecular line toward IRC+10216 with the Nobeyama 45-m telescope.
The Prime Focus Spectrograph (PFS) is a new facility instrument for Subaru Telescope which will be installed in around 2017. It is a multi-object spectrograph fed by about 2400 fibers placed at the prime focus covering a hexagonal field-of-view with 1.35 deg diagonals and capable of simultaneously obtaining data of spectra with wavelengths ranging from 0.38 um to 1.26 um. The spectrograph system is composed of four identical modules each receiving the light from 600 fibers. Each module incorporates three channels covering the wavelength ranges 0.38-0.65 mu (Blue), 0.63-0.97 mu (Red), and 0.94-1.26 mu (NIR) respectively; with resolving power which progresses fairly smoothly from about 2000 in the blue to about 4000 in the infrared. An additional spectral mode allows reaching a spectral resolution of 5000 at 0.8mu (red). The proposed optical design is based on a Schmidt collimator facing three Schmidt cameras (one per spectral channel). This architecture is very robust, well known and documented. It allows for high image quality with only few simple elements (high throughput) at the expense of the central obscuration, which leads to larger optics. Each module has to be modular in its design to allow for integration and tests and for its safe transport up to the telescope: this is the main driver for the mechanical design. In particular, each module will be firstly fully integrated and validated at LAM (France) before it is shipped to Hawaii. All sub-assemblies will be indexed on the bench to allow for their accurate repositioning. This paper will give an overview of the spectrograph system which has successfully passed the Critical Design Review (CDR) in 2014 March and which is now in the construction phase.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا