ﻻ يوجد ملخص باللغة العربية
The Keck Planet Imager and Characterizer (KPIC) is a purpose-built instrument for high-dispersion coronagraphy in the K and L bands on Keck. This instrument will provide the first high resolution (R$>$30,000) spectra of known directly imaged exoplanets and low-mass brown dwarf companions visible in the northern hemisphere. KPIC is developed in phases. Phase I is currently at Keck in the early operations stage, and the phase II upgrade will deploy in late 2021. The goal of phase II is to maximize the throughput for planet light and minimize the stellar leakage, hence reducing the exposure time needed to acquire spectra with a given signal-to-noise ratio. To achieve this, KPIC phase II exploits several innovative technologies that have not been combined this way before. These include a 1000-element deformable mirror for wavefront correction and speckle control, a set of lossless beam shaping optics to maximize coupling into the fiber, a pupil apodizer to suppress unwanted starlight, a pupil plane vortex mask to enable the acquisition of spectra at and within the diffraction limit, and an atmospheric dispersion compensator. These modules, when combined with the active fiber injection unit present in phase I, will make for a highly efficient exoplanet characterization platform. In this paper, we will present the final design of the optics and opto-mechanics and highlight some innovative solutions we implemented to facilitate all the new capabilities. We will provide an overview of the assembly and laboratory testing of the sub-modules and some of the results. Finally, we will outline the deployment timeline.
The accumulation of aberrations along the optical path in a telescope produces distortions and speckles in the resulting images, limiting the performance of cameras at high angular resolution. It is important to achieve the highest possible sensitivi
Adaptive optic (AO) systems delivering high levels of wavefront correction are now common at observatories. One of the main limitations to image quality after wavefront correction comes from atmospheric refraction. An Atmospheric dispersion compensat
High-dispersion coronagraphy (HDC) optimally combines high contrast imaging techniques such as adaptive optics/wavefront control plus coronagraphy to high spectral resolution spectroscopy. HDC is a critical pathway towards fully characterizing exopla
We discuss the use of parametric phase-diverse phase retrieval as an in-situ high-fidelity wavefront measurement method to characterize and optimize the transmitted wavefront of a high-contrast coronagraphic instrument. We apply our method to correct
The Keck Planet Imager and Characterizer comprises of a series of upgrades to the Keck II adaptive optics system and instrument suite to improve the direct imaging and high resolution spectroscopy capabilities of the facility instruments NIRC2 and NI