ترغب بنشر مسار تعليمي؟ اضغط هنا

Source mass characterization in the ARIADNE axion experiment

116   0   0.0 ( 0 )
 نشر من قبل Chloe Lohmeyer
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Axion Resonant InterAction Detection Experiment (ARIADNE) is a collaborative effort to search for the QCD axion using nuclear magnetic resonance (NMR), where the axion acts as a mediator of spin-dependent forces between an unpolarized tungsten source mass and a sample of polarized helium-3 gas. Since the experiment involves precision measurement of a small magnetization, it relies on limiting ordinary magnetic noise with superconducting magnetic shielding. In addition to the shielding, proper characterization of the noise level from other sources is crucial. We investigate one such noise source in detail: the magnetic noise due to impurities and Johnson noise in the tungsten source mass.

قيم البحث

اقرأ أيضاً

ARIADNE is a nuclear-magnetic-resonance-based experiment that will search for novel axion-induced spin-dependent interactions between an unpolarized source mass rotor and a nearby sample of spin-polarized $^3$He gas. To detect feeble axion signals at the sub-atto-Tesla level, the experiment relies on low magnetic background and noise. We measure and characterize the magnetic field background from a prototype tungsten rotor. We show that the requirement is met with our current level of tungsten purity and demagnetization process. We further show that the noise is dominantly caused by a few discrete dipoles, likely due to a few impurities trapped inside the rotor during manufacturing. This is done via a numerical optimization pipeline which fits for the locations and magnetic moments of each dipole. We find that under the current demagnetization, the magnetic moment of trapped impurities is bounded at $10^{-9} mathrm{A}mathrm{m}^2$.
The Axion Resonant InterAction Detection Experiment (ARIADNE) is a collaborative effort to search for the QCD axion using techniques based on nuclear magnetic resonance. In the experiment, axions or axion-like particles would mediate short-range spin -dependent interactions between a laser-polarized 3He gas and a rotating (unpolarized) tungsten source mass, acting as a tiny, fictitious magnetic field. The experiment has the potential to probe deep within the theoretically interesting regime for the QCD axion in the mass range of 0.1-10 meV, independently of cosmological assumptions. The experiment relies on a stable rotary mechanism and superconducting magnetic shielding, required to screen the 3He sample from ordinary magnetic noise. Progress on testing the stability of the rotary mechanism is reported, and the design for the superconducting shielding is discussed.
80 - Chuanya Cao , Jilei Xu , Miao He 2021
26,000 3-inch photomultiplier tubes (PMTs) have been produced for Jiangmen Underground Neutrino Observatory (JUNO) by the Hainan Zhanchuang Photonics Technology Co., Ltd (HZC) company in China and passed all acceptance tests with only 15 tubes reject ed. The mass production began in 2018 and elapsed for about 2 years at a rate of $sim$1,000~PMTs per month. The characterization of the PMTs was performed in the factory concurrently with production as a joint effort between HZC and JUNO. Fifteen performance parameters were tracked at different sampling rates, and novel working strategies were implemented to improve quality assurance. This constitutes the largest sample of 3-inch PMTs ever produced and studied in detail to date.
The COHERENT collaborations primary objective is to measure coherent elastic neutrino-nucleus scattering (CEvNS) using the unique, high-quality source of tens-of-MeV neutrinos provided by the Spallation Neutron Source (SNS) at Oak Ridge National Labo ratory (ORNL). In spite of its large cross section, the CEvNS process has never been observed, due to tiny energies of the resulting nuclear recoils which are out of reach for standard neutrino detectors. The measurement of CEvNS has now become feasible, thanks to the development of ultra-sensitive technology for rare decay and weakly-interacting massive particle (dark matter) searches. The CEvNS cross section is cleanly predicted in the standard model; hence its measurement provides a standard model test. It is relevant for supernova physics and supernova-neutrino detection, and enables validation of dark-matter detector background and detector-response models. In the long term, precision measurement of CEvNS will address questions of nuclear structure. COHERENT will deploy multiple detector technologies in a phased approach: a 14-kg CsI[Na] scintillating crystal, 15 kg of p-type point-contact germanium detectors, and 100 kg of liquid xenon in a two-phase time projection chamber. Following an extensive background measurement campaign, a location in the SNS basement has proven to be neutron-quiet and suitable for deployment of the COHERENT detector suite. The simultaneous deployment of the three COHERENT detector subsystems will test the $N^2$ dependence of the cross section and ensure an unambiguous discovery of CEvNS. This document describes concisely the COHERENT physics motivations, sensitivity and plans for measurements at the SNS to be accomplished on a four-year timescale.
The QCD axion is an hypothetical particle introduced to solve the strong CP problem of standard model of particle physics and is of interest as a possible component of cold dark matter. In the axion scenario, J.E. Moody and F. Wilczek showed that a n ew macroscopic long-range force, mediated by axion exchange, acts on electron spins, and that such force can be described in terms of an effective magnetic field. The QUAX-g$_p$g$_s$ experiment, carried out at INFN Laboratori Nazionali di Legnaro, is designed to search for the effects on magnetized samples of the effective field produced by unpolarized mass sources. As this field is macroscopic, it can be detected by measuring the change of magnetization of a paramagnetic Gadolinium silicate (GSO) crystal cooled at liquid helium temperature. The axion effective field induced magnetization can be detected with a SQUID magnetometer. By varying the position of the of source masses, the induced GSO magnetization is modulated at acoustic frequencies. Although the full QUAX-g$_p$g$_s$ sensitivity has not been yet exploited, we are able to measure a magnetization of $10^{-17}~$T at few tens of Hz. With this sensitivity we expect to further improve the upper limit of the coupling of the predicted long-range force in the $10^{-3}$ to $1~$m interval.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا