ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurement of time-dependent CP violation parameters in $B^0 to K_0^SK_0^SK_0^S$ decays at Belle

129   0   0.0 ( 0 )
 نشر من قبل Kookhyun Kang
 تاريخ النشر 2020
  مجال البحث
والبحث باللغة English




اسأل ChatGPT حول البحث

We measure the time-dependent $C!P$ violation parameters in $B^{0} to K^{0}_{S}K^{0}_{S}K^{0}_{S}$ decays using $772 times 10^6$ $B {mkern 1.5muoverline{mkern-1.5mu B mkern-0.1mu}mkern 0.1mu}$ pairs collected at the $Upsilon (4S)$ resonance with the Belle detector at the KEKB asymmetric-energy $e^+ e^-$ collider. The obtained mixing-induced and direct $C!P$ asymmetries are $-0.71 pm 0.23~{rm(stat)} pm 0.05~{rm(syst)}$ and $0.12 pm 0.16~{rm(stat)} pm 0.05~{rm(syst)}$, respectively. These values are consistent with the Standard Model predictions. The significance of $C!P$ violation differs from zero by 2.5 standard deviations.



قيم البحث

اقرأ أيضاً

We present a measurement of the time-dependent $CP$ violation parameters in $B^0toetaK^0$ decays. The measurement is based on the full data sample containing $772times 10^6$ $Bbar{B}$ pairs collected at the $Upsilon(4S)$ resonance using the Belle det ector at the KEKB asymmetric-energy $e^+e^-$ collider. The measured values of the mixing-induced and direct $CP$ violation parameters are: begin{align} sin 2 phi^{rm eff}_1 &= +0.68pm 0.07 pm 0.03, onumber mathcal{A}_{etaK^0} &= +0.03pm 0.05pm 0.04, onumber end{align} where the first uncertainty is statistical and the second is systematic. The values obtained are the most accurate to date. Furthermore, these results are consistent with our previous measurements and with the world-average value of $sin 2phi_1$ measured in $B^0to J/psi K^0$ decays.}
We report a measurement of time-dependent $CP$ violation in $B^0 to K^0_S pi^0 pi^0$ decays using a data sample of $772 times 10^6$ $Bbar{B}$ pairs collected by the Belle experiment runnin g at the $Upsilon (4S)$ resonance at the KEKB $e^+ e^-$ colli der. This decay proceeds mainly via a $bto sdbar{d}$ penguin amplitude. The results are $sin 2phi^{rm eff}_1 = 0.92^{+0.27}_{-0.31}~$ (stat.) $pm 0.11$ (syst.) and $mathcal{A} = 0.28 pm 0.21$ (stat.) $pm 0.04$ (syst.), which are the most precise measurements of $CP$ violati on in this decay mode to date. The value for the $CP$-violating parameter $sin 2phi^{rm eff}_1$ is consistent with that obtained using decay modes proceeding via a $bto cbar{c}s$ tree amplitude.
We report a measurement of time-dependent $CP$ violation parameters in ${B^0 to K_S^0 eta gamma}$ decays. The study is based on a data sample, containing ${772 times 10^6 Bbar{B}}$ pairs, that was collected at the $Upsilon(4S)$ resonance with the Bel le detector at the KEKB asymmetric-energy $e^+ e^-$ collider. We obtain the $CP$ violation parameters of ${{cal S} = -1.32 pm 0.77 {rm (stat.)} pm 0.36{rm (syst.)}}$ and ${{cal A} = -0.48 pm 0.41 {rm (stat.)} pm 0.07{rm (syst.)}}$ for the invariant mass of the $K_S^0 eta$ system up to 2.1 GeV/$c^2$.
We report improved measurements of time-dependent CP violation parameters for B^0(bar{B}^0) -> psi(2S) K_S. This analysis is based on a data sample of 657x10^6 BBbar pairs collected at the Y(4S) resonance with the Belle detector at the KEKB energy-as ymmetric e+e- collider. We fully reconstruct one neutral B meson in the psi(2S) K_S CP-eigenstate decay channel, and the flavor of the accompanying B meson is identified to be either B^0 or bar{B}^0 from its decay products. CP violation parameters are obtained from the asymmetries in the distributions of the proper-time intervals between the two B decays: S (psi(2S) K_S) = +0.72 +/- 0.09(stat) +/- 0.03(syst), A (psi(2S) K_S) = +0.04 +/- 0.07(stat) +/- 0.05(syst). These results are in agreement with results from measurements of B^0 -> J/psi K^0.
The decay-time-dependent $CP$ asymmetry in $B^{0}_{s}to J/psi K^{+} K^{-}$ decays is measured using proton-proton collision data, corresponding to an integrated luminosity of $1.9,mathrm{fb^{-1}}$, collected with the LHCb detector at a centre-of-mass energy of $13,mathrm{TeV}$ in 2015 and 2016. Using a sample of approximately 117,000 signal decays with an invariant $K^{+} K^{-}$ mass in the vicinity of the $phi(1020)$ resonance, the $CP$-violating phase $phi_s$ is measured, along with the difference in decay widths of the light and heavy mass eigenstates of the $B^{0}_{s}$-$bar{B}^{0}_{s}$ system, $DeltaGamma_s$. The difference of the average $B^{0}_{s}$ and $B^{0}$ meson decay widths, $Gamma_s-Gamma_d$, is determined using in addition a sample of $B^{0} to J/psi K^{+} pi^{-}$ decays. The values obtained are $phi_s = -0.083pm0.041pm0.006,mathrm{rad}$, $DeltaGamma_s = 0.077 pm 0.008 pm 0.003, mathrm{ps^{-1}}$ and $Gamma_s-Gamma_d = -0.0041 pm 0.0024 pm 0.0015,mathrm{ps^{-1}}$, where the first uncertainty is statistical and the second systematic. These are the most precise single measurements of these quantities to date and are consistent with expectations based on the Standard Model and with a previous LHCb analysis of this decay using data recorded at centre-of-mass energies 7 and 8 TeV. Finally, the results are combined with recent results from $B^{0}_{s}to J/psi pi^{+} pi^{-}$ decays obtained using the same dataset as this analysis, and with previous independent LHCb results.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا