ترغب بنشر مسار تعليمي؟ اضغط هنا

High-resolution for IAXO: MMC-based X-ray Detectors

99   0   0.0 ( 0 )
 نشر من قبل Daniel Unger
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low energy threshold would allow for investigating the ALP properties by studying the X-ray spectrum after its discovery. We propose to use low temperature metallic magnetic calorimeters (MMCs). Here we present the first detector system based on MMCs developed for IAXO and discuss the results of the characterization. The detector consists of a two-dimensional 64-pixel array covering an active area of 16 mm$^2$ with a fill factor of 93 %. We achieve an average energy resolution of 6.1 eV FWHM allowing for energy thresholds below 100 eV. This detector is the first step towards a larger 1 cm$^2$ array matching the IAXO X-ray optics. We determine the background rate for an unshielded detector system in the energy range between 1 keV and 10 keV to be $3.2(1) times 10^{-4}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ from events acquired over 30 days. In the future, active and passive shields will significantly reduce the background induced by cosmic muons and natural radioactivity. Our results demonstrate that MMCs are a promising technology for helioscopes to discover and study ALPs.



قيم البحث

اقرأ أيضاً

Cadmium Zinc Telluride and Cadmium Telluride are the detector materials of choice for the detection of X-rays in the X-ray energy band E >= 5keV with excellent spatial and spectral resolution and without cryogenic cooling. Owing to recent breakthroug hs in grazing incidence mirror technology, next-generation hard X-ray telescopes will achieve angular resolution between 5 and 10 arc seconds - about an order of magnitude better than that of the NuSTAR hard X-ray telescope. As a consequence, the next generation of X-ray telescopes will require pixelated X-ray detectors with pixels on a grid with a lattice constant of <= 250um. Additional detector requirements include a low energy threshold of less than 5keV and an energy resolution of less than one keV. The science drivers for a high angular-resolution X-ray mission include studies and measurements of black hole spins, the cosmic evolution of super-massive black holes, active galactic nuclei feedback, and the behaviour of matter at very high densities. In this contribution, we report on our R&D studies with the goal to optimise small-pixel Cadmium Zinc Telluride and Cadmium Telluride detectors.
383 - R. Adams , R. Bates , C. Da Via 1997
Thick epitaxial layers have been grown using Low Pressure Vapour Phase Epitaxy techniques with low free carrier concentrations . This type of material is attractive as a medium for X-ray detection, because of its high conversion efficiency for X-rays in the medically interesting energy range.
Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking efficiency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a gas gain of 20000. The ATLAS MDT chambers are designed to cope with background counting rates due to neutrons and gamma-rays of up to about 300 kHz per tube which will be exceeded for LHC luminosities larger than the design value of 10-34 per square cm and second. Decreasing the drift-tube diameter to 15 mm while keeping the other parameters, including the gas gain, unchanged reduces the maximum drift time from about 700 ns to 200 ns and the drift-tube occupancy by a factor of 7. New drift-tube chambers for the endcap regions of the ATLAS muon spectrometer have been designed. A prototype chamber consisting of 12 times 8 layers of 15 mm diameter drift tubes of 1 m length has been constructed with a sense wire positioning accuracy of 20 microns. The 15 mm diameter drift-tubes have been tested with cosmic rays in the Gamma Irradiation Facility at CERN at counting rates of up to 1.85 MHz.
Energy-dispersive X-ray diffraction (EDXRD) is extremely insensitive to sample morphology when implemented in a back-reflection geometry. The capabilities of this non-invasive technique for cultural heritage applications have been explored at high re solution at the Diamond Light Source synchrotron. The results of the XRD analysis of the pigments in 40 paints, commonly used by 20th century artists, are reported here. It was found that synthetic organic pigments yielded weak diffraction patterns at best, and it was not possible to unambiguously identify any of these pigments. In contrast, the majority of the paints containing inorganic pigments yielded good diffraction patterns amenable to crystallographic analysis. The high resolution of the technique enables the extraction of a range of detailed information: phase identification (including solid solutions), highly accurate unit cell parameters, phase quantification, crystallite size and strain parameters and preferred orientation parameters. The implications of these results for application to real paintings are discussed, along with the possibility to transfer the technique away from the synchrotron and into the laboratory and museum through the use of state-of-the-art microcalorimeter detectors. The results presented demonstrate the exciting potential of the technique for art history and authentication studies, based on the non-invasive acquisition of very high quality crystallographic data.
We are preparing for an ultra-high resolution x-ray spectroscopy of kaonic atoms using an x-ray spectrometer based on an array of superconducting transition-edge-sensor microcalorimeters developed by NIST. The instrument has excellent energy resoluti ons of 2 - 3 eV (FWHM) at 6 keV and a large collecting area of about 20 mm^2. This will open new door to investigate kaon-nucleus strong interaction and provide new accurate charged-kaon mass value.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا