ترغب بنشر مسار تعليمي؟ اضغط هنا

A Design-Based Model of the Aortic Valve for Fluid-Structure Interaction

152   0   0.0 ( 0 )
 نشر من قبل Alexander Kaiser
 تاريخ النشر 2020
  مجال البحث علم الأحياء
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper presents a new method for modeling the mechanics of the aortic valve, and simulates its interaction with blood. As much as possible, the model construction is based on first principles, but such that the model is consistent with experimental observations. We require that tension in the leaflets must support a pressure, then derive a system of partial differential equations governing its mechanical equilibrium. The solution to these differential equations is referred to as the predicted loaded configuration; it includes the loaded leaflet geometry, fiber orientations and tensions needed to support the prescribed load. From this configuration, we derive a reference configuration and constitutive law. In fluid-structure interaction simulations with the immersed boundary method, the model seals reliably under physiological pressures, and opens freely over multiple cardiac cycles. Further, model closure is robust to extreme hypo- and hypertensive pressures. Then, exploiting the unique features of this model construction, we conduct experiments on reference configurations, constitutive laws, and gross morphology. These experiments suggest the following conclusions, which are directly applicable to the design of prosthetic aortic valves. (i) The loaded geometry, tensions and tangent moduli primarily determine model function. (ii) Alterations to the reference configuration have little effect if the predicted loaded configuration is identical. (iii) The leaflets must have sufficiently nonlinear material response to function over a variety of pressures. (iv) Valve performance is highly sensitive to free edge length and leaflet height. For future use, our aortic valve modeling framework offers flexibility in patient-specific models of cardiac flow.

قيم البحث

اقرأ أيضاً

The aortic valve is a three-leaflet passive structure that, driven by pressure differences between the left ventricle and the aorta, opens and closes during the heartbeat to ensure the correct stream direction and flow rate. In elderly individuals or because of particular pathologies, the valve leaflets can stiffen thus impairing the valve functioning and, in turn, the pumping efficiency of the heart. Using a multi-physics left heart model accounting for the electrophysiology, the active contraction of the myocardium, the hemodynamics and the related fluid-structure-interaction, we have investigated the changes in the flow features for different severities of the aortic valve stenosis. We have found that, in addition to the increase of the transvalvular pressure drop and of the systolic jet velocity, a stenotic aortic valve significantly alters the wall shear stresses and their spatial distribution over the aortic arch and valve leaflets, which may induce a remodelling process of the ventricular myocardium. The numerical results from the multi-physics model are fully consistent with the clinical experience, thus further opening the way for computational engineering aided medical diagnostic.
This work is concerned with modeling and simulation of the mitral valve, one of the four valves in the human heart. The valve is composed of leaflets, the free edges of which are supported by a system of chordae, which themselves are anchored to the papillary muscles inside the left ventricle. First, we examine valve anatomy and present the results of original dissections. These display the gross anatomy and information on fiber structure of the mitral valve. Next, we build a model valve following a design-based methodology, meaning that we derive the model geometry and the forces that are needed to support a given load, and construct the model accordingly. We incorporate information from the dissections to specify the fiber topology of this model. We assume the valve achieves mechanical equilibrium while supporting a static pressure load. The solution to the resulting differential equations determines the pressurized configuration of the valve model. To complete the model we then specify a constitutive law based on a stress-strain relation consistent with experimental data that achieves the necessary forces computed in previous steps. Finally, using the immersed boundary method, we simulate the model valve in fluid in a computer test chamber. The model opens easily and closes without leak when driven by physiological pressures over multiple beats. Further, its closure is robust to driving pressures that lack atrial systole or are much lower or higher than normal.
122 - Vincenzo Bonifaci 2016
Optimization of fluid transport in the slime mold Physarum polycephalum has been the subject of several modeling efforts in recent literature. Existing models assume that the tube adaptation mechanism in P. polycephalums tubular network is controlled by the sheer amount of fluid flow through the tubes. We put forward the hypothesis that the controlling variable may instead be the flows pressure gradient along the tube. We carry out the stability analysis of such a revised mathematical model for a parallel-edge network, proving that the revised model supports the global flow-optimizing behavior of the slime mold for a substantially wider class of response functions compared to previous models. Simulations also suggest that the same conclusion may be valid for arbitrary network topologies.
176 - Yonghui Qiao , Le Mao , Yan Wang 2021
Thoracic endovascular aortic repair (TEVAR) has developed to be the most effective treatment for aortic diseases. The objective of this study is to evaluate the biomechanical implications of the implanted endograft after TEVAR. We present a novel ima ge-based, patient-specific, fluid-structure computational framework. The geometries of blood, endograft, and aortic wall were reconstructed based on clinical images. Patient-specific measurement data was collected to determine the parameters of the three-element Windkessel. We designed three postoperative scenarios with rigid wall assumption, blood-wall interaction, blood-endograft-wall interplay, respectively, where a two-way fluid-structure interaction (FSI) method was applied to predict the deformation of the composite stent-wall. Results show that flow energy loss (EL) during a cardiac cycle is underestimated by the rigid wall assumption. The complete storage and release process of blood flow energy, which consists of four phases is firstly captured. The implantation of the endograft would weaken the buffer function of the aorta and reduce mean EL by 19.1%. The closed curve area of wall pressure and aortic volume could indicate the EL caused by the interaction between blood flow and wall deformation. Both the FSI and endograft have a slight effect on wall shear stress-related-indices. The deformability of the composite stent-wall region is remarkably limited by the endograft. Our results highlight the importance of considering both the FSI method and the biomechanical implications of endograft to acquire physiologically-accurate hemodynamics in post-TEVAR computational studies and that neglecting the effect of the endograft would overestimate the blood flow EL and aortic deformability.
In this paper we consider chemotherapy in a spatial model of tumor growth. The model, which is of reaction-diffusion type, takes into account the complex interactions between the tumor and surrounding stromal cells by including densities of endotheli al cells and the extra-cellular matrix. When no treatment is applied the model reproduces the typical dynamics of early tumor growth. The initially avascular tumor reaches a diffusion limited size of the order of millimeters and initiates angiogenesis through the release of vascular endothelial growth factor (VEGF) secreted by hypoxic cells in the core of the tumor. This stimulates endothelial cells to migrate towards the tumor and establishes a nutrient supply sufficient for sustained invasion. To this model we apply cytostatic treatment in the form of a VEGF-inhibitor, which reduces the proliferation and chemotaxis of endothelial cells. This treatment has the capability to reduce tumor mass, but more importantly, we were able to determine that inhibition of endothelial cell proliferation is the more important of the two cellular functions targeted by the drug. Further, we considered the application of a cytotoxic drug that targets proliferating tumor cells. The drug was treated as a diffusible substance entering the tissue from the blood vessels. Our results show that depending on the characteristics of the drug it can either reduce the tumor mass significantly or in fact accelerate the growth rate of the tumor. This result seems to be due to complicated interplay between the stromal and tumor cell types and highlights the importance of considering chemotherapy in a spatial context.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا