ترغب بنشر مسار تعليمي؟ اضغط هنا

Vector magneto-optical magnetometer based on the resonant all-dielectric gratings with highly anisotropic iron-garnet films

149   0   0.0 ( 0 )
 نشر من قبل Andrey Kalish
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English
 تأليف D. O. Ignatyeva




اسأل ChatGPT حول البحث

A sensitive vector magnetometry with high spatial resolution is important for various practical applications, such as magnetocardiography, magnetoencephalography, explosive materials detection and many others. We propose a magnetometer based on the magnetic iron-garnet film possessing a very high magnetic anisotropy, placed in the rotating external magnetic field. Each of the measured magnetic field spatial components produces different temporal harmonics in the out-of-plane magnetization dependence. The dielectric resonant grating placed on the top of an ultrathin film enhanced the magneto-optical response 10 times which makes it possible to achieve 10 times higher spatial resolution in the perpendicular to the film direction. The reported magneto-optical magnetometer allows one to measure simultaneously all three spatial components of the magnetic field with high spatial resolution and sensitivity up to 100 pT/Hz$^{1/2}$.

قيم البحث

اقرأ أيضاً

We report an all-optical atomic vector magnetometer using dual Bell-Bloom optical pumping beams in a Rb vapor cell. This vector magnetometer consists of two orthogonal optical pumping beams, with amplitude modulations at $^{85}$Rb and $^{87}$Rb Larmo r frequencies respectively. We simultaneously detect atomic signals excited by these two pumping beams using a single probe beam in the third direction, and extract the field orientation information using the phase delays between the modulated atomic signals and the driving beams. By adding a Herriott cavity inside the vapor cell, we improve the magnetometer sensitivity. We study the performance of this vector magnetometer in a magnetic field ranging from 100~mG to 500~mG, and demonstrate a field angle sensitivity better than 10~${mu}$rad/Hz$^{1/2}$ above 10~Hz.
70 - S. Afach , G. Ban , G. Bison 2015
We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $mu$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 $mu$rad for integration times from 10 s up to 2000 s.
We report on an all-optical magnetometric technique based on nonlinear magneto-optical rotation with amplitude-modulated light. The method enables sensitive magnetic-field measurements in a broad dynamic range. We demonstrate the sensitivity of $4.3t imes10^{-9}$ G/$sqrt{text{Hz}}$ at 10 mG and the magnetic field tracking in a range of 40 mG. The fundamental limits of the method sensitivity and factors determining current performance of the magnetometer are discussed.
Finding an electronic transition a subtle excitation of which can launch dramatic changes of electric, optical or magnetic properties of media is one of the long-standing dreams in the field of photo-induced phase transitions [1-5]. Therefore the dis covery of the magnetization switching only by a femtosecond laser pulse [6-10] triggered intense discussions about mechanisms responsible for these laser-induced changes. Here we report the experimentally revealed selection rules on polarization and wavelengths of ultrafast photo-magnetic recording in Co-doped garnet film and identify the workspace of the parameters (magnetic damping, wavelength and polarization of light) allowing this effect. The all-optical magnetic switching under both single pulse and multiple-pulse sequences can be achieved at room temperature, in narrow spectral ranges with light polarized either along <110> or <100> crystallographic axes of the garnet. The revealed selection rules indicate that the excitations responsible for the coupling of light to spins are d-electron transitions in octahedral and tetrahedral Co-sublattices, respectively.
The magneto-optical activity, namely the polarization conversion capabilities of high-index, non-absorbing, core-shell dielectric nanospheres is theoretically analyzed. We show that, in analogy with their plasmonic counterparts, the polarization conv ersion in resonant dielectric particles is linked to the amount of electromagnetic field probing the magneto-optical material in the system. However, in strong contrast with plasmon nanoparticles, due to the peculiar distribution of the internal fields in resonant dielectric spheres, the magneto-optical response is fully governed by the magnetic (dipolar and quadrupolar) resonances with little effect of the electric ones.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا