ترغب بنشر مسار تعليمي؟ اضغط هنا

The Herschel SPIRE Fourier Transform Spectrometer Spectral Feature Finder V. Rotational measurements of NGC 891

344   0   0.0 ( 0 )
 نشر من قبل Chris Benson
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Chris S. Benson




اسأل ChatGPT حول البحث

The ESA Herschel Spectral and Photometric Imaging Receiver (SPIRE) Fourier Transform Spectrometer (FTS) Spectral Feature Finder (FF) project is an automated spectral feature fitting routine developed within the SPIRE instrument team to extract all prominent spectral features from all publicly available SPIRE FTS observations. In this work, we demonstrate the use of the FF information extracted from three observations of the edge-on spiral galaxy NGC 891 to measure the rotation of NII and CI gas at Far-infrared frequencies in complement to radio observations of the HI 21cm line and the CO(1-0) transition as well as optical measurements of Halpha. We find that measurements of both NII and CI gas follow a similar velocity profile to that of HI and Halpha showing a correlation between neutral and ionized regions of the interstellar medium (ISM) in the disk of NGC 891.



قيم البحث

اقرأ أيضاً

We provide a detailed description of the Herschel-SPIRE Fourier Transform Spectrometer (FTS) Spectral Feature Finder (FF). The FF is an automated process designed to extract significant spectral features from SPIRE FTS data products. Optimising the n umber of features found in SPIRE-FTS spectra is challenging. The wide SPIRE-FTS frequency range (447-1568 GHz) leads to many molecular species and atomic fine structure lines falling within the observed bands. As the best spectral resolution of the SPIRE-FTS is ~1.2 GHz, there can be significant line blending, depending on the source type. In order to find, both efficiently and reliably, features in spectra associated with a wide range of sources, the FF iteratively searches for peaks over a number of signal-to-noise ratio (SNR) thresholds. For each threshold, newly identified features are rigorously checked before being added to the fitting model. At the end of each iteration, the FF simultaneously fits the continuum and features found, with the resulting residual spectrum used in the next iteration. The final FF products report the frequency of the features found and the associated SNRs. Line flux determination is not included as part of the FF products, as extracting reliable line flux from SPIRE-FTS data is a complex process that requires careful evaluation and analysis of the spectra on a case-by-case basis. The FF results are 100% complete for features with SNR greater than 10 and 50-70% complete at SNR of 5. The FF code and all FF products are publicly available via the Herschel Science Archive.
The Herschel SPIRE FTS Spectral Feature Finder (FF) detects significant spectral features within SPIRE spectra and employs two routines, and external references, to estimate source radial velocity. The first routine is based on the identification of rotational CO emission, the second cross-correlates detected features with a line template containing most of the characteristic lines in typical far infra-red observations. In this paper, we outline and validate these routines, summarise the results as they pertain to the FF, and comment on how external references were incorporated.
The ESA Herschel Spectral and Photometric Imaging Receiver (SPIRE) Fourier Transform Spectrometer (FTS) Spectral Feature Finder (FF) project is an automated spectral feature fitting routine developed within the SPIRE instrument team to extract all pr ominent spectral features from all publicly available SPIRE FTS observations. We present the extension of the FF to include the off-axis detectors of the FTS in sparsely sampled single-pointing observations, the results of which have been ingested into the catalogue. We also present the results from an automated routine for identifications of the atomic/molecular transitions that correspond to the spectral features extracted by the FF. We use a template of 307 atomic fine structure and molecular lines that are commonly found in SPIRE FTS spectra for the cross-match. The routine makes use of information provided by the line identification to search for low signal-to-noise ratio features that have been excluded or missed by the iterative FF. In total, the atomic/molecular transitions of 178,942 lines are identified (corresponding to 83% of the entire FF catalogue), and an additional 33,840 spectral lines associated with missing features from SPIRE FTS observations are added to the FF catalogue.
The SPIRE FTS Spectral Feature Finder (FF), developed within the Herschel Spectral and Photometric Imaging Receiver (SPIRE) Fourier Transform Spectrometer (FTS) instrument team, is an automated spectral feature fitting routine that attempts to find s ignificant features in SPIRE FTS spectra. The $^3$P$_1$ - $^3$P$_0$ and $^3$P$_2$ - $^3$P$_1$ neutral carbon fine structure lines are common features in carbon rich far-infrared astrophysical sources. These features can be difficult to detect using an automated feature detection routine due to their typically low amplitude and line blending. In this paper we describe and validate the FF sub-routine designed to detect the neutral carbon emission observed in SPIRE spectral data.
A systematic programme of calibration observations was carried out to monitor the performance of the SPIRE FTS instrument on board the Herschel Space Observatory. Observations of planets (including the prime point-source calibrator, Uranus), asteroid s, line sources, dark sky, and cross-calibration sources were made in order to monitor repeatability and sensitivity, and to improve FTS calibration. We present a complete analysis of the full set of calibration observations and use them to assess the performance of the FTS. Particular care is taken to understand and separate out the effect of pointing uncertainties, including the position of the internal beam steering mirror for sparse observations in the early part of the mission. The repeatability of spectral line centre positions is <5km/s, for lines with signal-to-noise ratios >40, corresponding to <0.5-2.0% of a resolution element. For spectral line flux, the repeatability is better than 6%, which improves to 1-2% for spectra corrected for pointing offsets. The continuum repeatability is 4.4% for the SLW band and 13.6% for the SSW band, which reduces to ~1% once the data have been corrected for pointing offsets. Observations of dark sky were used to assess the sensitivity and the systematic offset in the continuum, both of which were found to be consistent across the FTS detector arrays. The average point-source calibrated sensitivity for the centre detectors is 0.20 and 0.21 Jy [1 sigma; 1 hour], for SLW and SSW. The average continuum offset is 0.40 Jy for the SLW band and 0.28 Jy for the SSW band.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا