ترغب بنشر مسار تعليمي؟ اضغط هنا

The Fundamental Reference AGN Monitoring Experiment (FRAMEx)

460   0   0.0 ( 0 )
 نشر من قبل Bryan Dorland
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English
 تأليف B. Dorland




اسأل ChatGPT حول البحث

The U.S. Naval Observatory (USNO), in collaboration with Paris Observatory (OP), is conducting the Fundamental Reference AGN Monitoring Experiment, or FRAMEx. FRAMEx will use USNOs and OPs in-house observing assets in the radio, infrared (IR) and visible, as well as other ground- and space-based telescopes (e.g., in the X-ray) that we can access for these purposes, to observe and monitor current and candidate Reference Frame Objects (RFOs) -- consisting of Active Galactic Nuclei (AGN) -- as well as representative AGN, in order to better understand astrometric and photometric variability at multiple timescales. FRAMEx will improve the selection of RFOs as well as provide significant new data to the AGN research community. This paper describes the FRAMEx objectives, specific areas of investigation, and the initial data collection campaigns.

قيم البحث

اقرأ أيضاً

We present the first results from the Fundamental Reference AGN Monitoring Experiment (FRAMEx), an observational campaign dedicated to understanding the physical processes that affect the apparent positions and morphologies of AGNs. In this work, we obtained simultaneous Swift X-ray Telescope (XRT) and Very Long Baseline Array (VLBA) radio observations for a snapshot campaign of 25 local AGNs that form a volume-complete sample with hard X-ray (14-195 keV) luminosities above $10^{42}$erg s$^{-1}$, out to a distance of 40 Mpc. Despite achieving an observation depth of $sim20$ $mu$Jy, we find that 16 of 25 AGNs in our sample are not detected with the VLBA on milli-arcsecond (sub-parsec) scales, and the corresponding core radio luminosity upper limits are systematically below predictions from the Fundamental Plane of black hole activity. Using archival Jansky Very Large Array (VLA) radio measurements, our sample jumps back onto the Fundamental Plane, suggesting that extended radio emission is responsible for the apparent correlation between radio emission, X-ray emission, and black hole mass. We suggest that this discrepancy is likely due to extra-nuclear radio emission produced via interactions between the AGN and host environment. We compare VLBA observations of AGNs to VLA observations of nearby Galactic black holes (GBHs) and we find a mass-independent correlation between radio and X-ray luminosities of black holes of $L_mathrm{6cm}$/$L_mathrm{2-10 keV}$ $sim$ 10$^{-6}$, in line with predictions for coronal emission, but allowing for the possibility of truly radio silent AGNs.
The quality of the incoming experimental data has a significant importance for both analysis and running the experiment. The main point of the Baikal-GVD DQM system is to monitor the status of the detector and obtained data on the run-by-run based an alysis. It should be fast enough to be able to provide analysis results to detector shifter and for participation in the global multi-messaging system.
The main purpose of the Baikal-GVD Data Quality Monitoring (DQM) system is to monitor the status of the detector and collected data. The system estimates quality of the recorded signals and performs the data validation. The DQM system is integrated w ith the Baikal-GVDs unified software framework (BARS) and operates in quasi-online manner. This allows us to react promptly and effectively to the changes in the telescope conditions.
Astrometry, the measurement of positions and motions of the stars, is one of the oldest disciplines in Astronomy, extending back at least as far as Hipparchus discovery of the precession of Earths axes in 190 BCE by comparing his catalog with those o f his predecessors. Astrometry is fundamental to Astronomy, and critical to many aspects of Astrophysics and Geodesy. In order to understand our planets and solar systems context within their surroundings, we must be able to to define, quantify, study, refine, and maintain an inertial frame of reference relative to which all positions and motions can be unambiguously and self-consistently described. It is only by using this inertial reference frame that we are able to disentangle our observations of the motions of celestial objects from our own complex path around our star, and its path through the galaxy, and the local group. Every aspect of each area outlined in the call for scientific frontiers in astronomy in the era of the 2020-2030 timeframe will depend on the quality of the inertial reference frame. In this white paper, we propose support for development of radio Very Long Baseline Interferometry (VLBI) capabilities, including the Next Generation Very Large Array (ngVLA), a radio astronomy observatory that will not only support development of a next generation reference frame of unprecedented accuracy, but that will also serve as a highly capable astronomical instrument in its own right. Much like its predecessors, the Very Long Baseline Array (VLBA) and other VLBI telescopes, the proposed ngVLA will provide the foundation for the next three decades for the fundamental reference frame, benefitting astronomy, astrophysics, and geodesy alike.
1ES 1927+654 is a nearby active galactic nucleus (AGN) which underwent a changing-look event in early 2018, developing prominent broad Balmer lines which were absent in previous observations. We have followed up this object in the X-rays with an ongo ing campaign that started in May 2018, and that includes 265 NICER (for a total of 678ks) and 14 Swift/XRT (26ks) observations, as well as three simultaneous XMM-Newton/NuSTAR (158/169 ks) exposures. In the X-rays, 1ES 1927+654 shows a behaviour unlike any previously known AGN. The source is extremely variable both in spectral shape and flux, and does not show any correlation between X-ray and UV flux on timescales of hours or weeks/months. After the outburst the power-law component almost completely disappeared, and the source showed an extremely soft continuum dominated by a blackbody component. The temperature of the blackbody increases with the luminosity, going from $kTsim 80$eV (for a 0.3--2keV luminosity of $L_{0.3-2}sim 10^{41.5}rm,erg,s^{-1}$) to $sim 200$eV (for $L_{0.3-2}sim 10^{44}rm,erg,s^{-1}$). The spectra show evidence of ionized outflows, and of a prominent feature at $sim 1$keV, which can be reproduced by a broad emission line. The unique characteristics of 1ES 1927+654 in the X-ray band suggest that it belongs to a new type of changing-look AGN. Future X-ray surveys might detect several more objects with similar properties.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا