ترغب بنشر مسار تعليمي؟ اضغط هنا

Nonlinear Virtual Inertia Control of WTGs for Enhancing Primary Frequency Response and Suppressing Drive-Train Torsional Oscillations

205   0   0.0 ( 0 )
 نشر من قبل Junbo Zhao
 تاريخ النشر 2020
والبحث باللغة English




اسأل ChatGPT حول البحث

Virtual inertia controllers (VICs) for wind turbine generators (WTGs) have been recently developed to compensate for the reduction of inertia in power systems. However, VICs can induce low-frequency torsional oscillations of the drive train of WTGs. This paper addresses this issue and develops a new nonlinear VIC based on objective holographic feedbacks theory. This approach allows transforming the objectives that require improvement into a completely controllable system of Brunovskys type. Simulation results under various scenarios demonstrate that the proposed method outperforms existing VICs in terms of suppression of WTG low-frequency drive-train torsional oscillations, enhancement of system frequency nadir as well as fast and smooth recovery of WTG rotor speed to the original MPP before the disturbance. The proposed method is also able to coordinate multiple WTGs.

قيم البحث

اقرأ أيضاً

With the increasing impact of low inertia due to the high penetration of distributed generation, virtual synchronous generator (VSG) technology has been proposed to improve the stability of the inverter-interfaced distributed generator by providing v irtual inertia. This paper presents a recent review of virtual inertia control covering significance, features, design principles, and state-of-art inertia strategies from both physical and mathematical perspectives to facilitate the wide application of the VSG. The definition and source of virtual inertia are given to help researchers to establish the concept of virtual inertia. Then, this paper covers influencing mechanism studies of virtual inertia to reveal its functions. Also, a design framework of the virtual inertia is established by considering both the characteristics of the control system and the limitation of energy storage systems and renewable energy resources. Finally, several novel adaptive inertia control strategies are reviewed, and some aspects of potential future research are recommended.
The virtual synchronous generator technology analogs the characteristics of the synchronous generator via the controller design. It improved the stability of the grid systems which include the new energy. At the same time, according to the adjustable characteristics of the virtual synchronous generator parameters, the parameter adaptive adjustment is used to improve the dynamic performance of the system. However, the traditional virtual synchronous generator adaptive control technology still has two drawbacks: on the one hand, the large-scale adjustment of the damping droop coefficient and the virtual moment of inertia requires the system having a high energy storage margin; On the other hand, there is a power overshoot phenomenon in the transient regulation process, which is disadvantageous to the power equipment. First, this paper provides a convenient adjustment method for improving the transient stability of the system, the system damping is adjusted by introducing the output speed feedback. Second, according to the transient power-angle characteristics of the system, a parameter adaptive control strategy is proposed, which shortens the transient adjustment time and ensures that the deviation of the system frequency in the transient adjustment process is within the allowable range, and improves the transient performance of the grid frequency adjustment, at the same time, the power overshoot is suppressed. Finally, the experimental results show that the proposed control strategy is superior to the existing adaptive control strategy.
In this paper, we present a virtual control contraction metric (VCCM) based nonlinear parameter-varying (NPV) approach to design a state-feedback controller for a control moment gyroscope (CMG) to track a user-defined trajectory set. This VCCM based nonlinear stabilization and performance synthesis approach, which is similar to linear parameter-varying (LPV) control approaches, allows to achieve exact guarantees of exponential stability and $mathcal{L}_2$-gain performance on nonlinear systems with respect to all trajectories from the predetermined set, which is not the case with the conventional LPV methods. Simulation and experimental studies conducted in both fully- and under-actuated operating modes of the CMG show effectiveness of this approach compared to standard LPV control methods.
The power system frequency is important for the system overall stability. However, there does not exist a single measurement point of the system frequency due to the distributed nature of the system inertia and the small inconsistency of different ge nerator rotor electrical speeds in one synchronized system. This paper proposed a new approach to calculate the system center-of-inertia (COI) frequency and the rate-of-change-of-frequency (RoCoF) more accurately using PMU data at multiple locations. The COI frequency and the RoCoF value were further used to assist fast estimation of the imbalance MW amount of a frequency event. Test results using actual measurements in the U.S. Eastern Interconnection system validated the effectiveness of the proposed method.
The need for Enhanced Frequency Response (EFR) is expected to increase significantly in future low-carbon Great Britain (GB) power system. One way to provide EFR is to use power electronic compensators (PECs) for point-of-load voltage control (PVC) t o exploit the voltage dependence of loads. This paper investigates the techno-economic feasibility of such technology in future GB power system by quantifying the total EFR obtainable through deploying PVC in the urban domestic sector, the investment cost of the installment and the economic and environmental benefits of using PVC. The quantification is based on a stochastic domestic demand model and generic medium and low-voltage distribution networks for the urban areas of GB and a stochastic unit commitment (SUC) model with constraints for secure post-fault frequency evolution is used for the value assessment. Two future energy scenarios in the backdrop of 2030 with `smart and `non-smart control of electric vehicles and heat pumps, under different levels of penetration of battery energy storage system (BESS) are considered to assess the value of PEC, as well as the associated payback period. It is demonstrated that PVC could effectively complement BESS towards EFR provision in future GB power system.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا