ترغب بنشر مسار تعليمي؟ اضغط هنا

Quantum Squeezing Schemes for Heterodyne Readout

188   0   0.0 ( 0 )
 نشر من قبل Teng Zhang
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Advanced gravitational-wave detectors are limited by quantum noise in their most sensitive frequency band. Quantum noise suppression techniques, such as the application of the quantum squeezed state of light, have been actively studied in the context of homodyne readouts. In this paper, we consider quantum squeezing schemes for the heterodyne readouts. This is motivated by a successful suppression of the higher-order-mode content by stable recycling cavities in advanced detectors. The heterodyne readout scheme requires precise tuning of the interferometer parameters and a broadband squeezing source, but is conceptually simple and elegant. We further show that it is compatible with the frequency-dependent squeezing, which reduces both the shot noise and the radiation-pressure noise. We propose a test of the heterodyne readout with squeezing in Advanced LIGO. This can serve as a pathfinder not only for the implementation in future detectors, such as Einstein Telescope and Cosmic Explorer, but also for general high-precision optical measurements.



قيم البحث

اقرأ أيضاً

Precision measurements using traditional heterodyne readout suffer a 3dB quantum noise penalty compared with homodyne readout. The extra noise is caused by the quantum fluctuations in the image vacuum. We propose a two-carrier gravitational-wave dete ctor design that evades the 3dB quantum penalty of heterodyne readout. We further propose a new way of realising frequency-dependent squeezing utilising two-mode squeezing in our scheme. It naturally achieves more precise audio frequency signal measurements with radio frequency squeezing. In addition, the detector is compatible with other quantum nondemolition techniques.
In order to expand the astrophysical reach of gravitational wave detectors, several interferometer topologies have been proposed to evade the thermodynamic and quantum mechanical limits in future detectors. In this work, we make a systematic comparis on among them by considering their sensitivities and complexities. We numerically optimize their sensitivities by introducing a cost function that tries to maximize the broadband improvement over the sensitivity of current detectors. We find that frequency-dependent squeezed-light injection with a hundred-meter scale filter cavity yields a good broadband sensitivity, with low complexity, and good robustness against optical loss. This study gives us a guideline for the near-term experimental research programs in enhancing the performance of future gravitational-wave detectors.
Quantum cascade detectors (QCD) are unipolar infrared devices where the transport of the photo excited carriers takes place through confined electronic states, without an applied bias. In this photovoltaic mode, the detectors noise is not dominated b y a dark shot noise process, therefore, performances are less degraded at high temperature with respect to photoconductive detectors. This work describes a 9 um QCD embedded into a patch-antenna metamaterial which operates with state-of-the-art performances. The metamaterial gathers photons on a collection area, Acoll, much bigger than the geometrical area of the detector, improving the signal to noise ratio up to room temperature. The background-limited detectivity at 83 K is 5.5 x 10^10 cm Hz^1/2 W^-1, while at room temperature, the responsivity is 50 mA/W at 0 V bias. Patch antenna QCD is an ideal receiver for a heterodyne detection set-up, where a signal at a frequency 1.4 GHz and T=295 K is reported as first demonstration of uncooled 9um photovoltaic receivers with GHz electrical bandwidth. These findings guide the research towards uncooled IR quantum limited detection.
The New Iram Kid Arrays-2 (NIKA2) instrument has recently been installed at the IRAM 30 m telescope. NIKA2 is a state-of-art instrument dedicated to mm-wave astronomy using microwave kinetic inductance detectors (KID) as sensors. The three arrays ins talled in the camera, two at 1.25 mm and one at 2.05 mm, feature a total of 3300 KIDs. To instrument these large array of detectors, a specifically designed electronics, composed of 20 readout boards and hosted in three microTCA crates, has been developed. The implemented solution and the achieved performances are presented in this paper. We find that multiplexing factors of up to 400 detectors per board can be achieved with homogeneous performance across boards in real observing conditions, and a factor of more than 3 decrease in volume with respect to previous generations.
We propose a sensitive new detector based on Cooper pair breaking in a superconductor. The quantum capacitor detector (QCD) exploits the extraordinary sensitivity of superconducting single-electron devices to the presence of quasiparticles generated by pair-breaking photons. This concept would enable single-photon detection at far-IR and sub-millimeter frequencies with detector sensitivities that exceed that of transition-edge-sensor bolometers (TES), kinetic inductance detectors (KID), and superconducting tunnel junction detectors (STJ). The detectors we propose are based on the single Cooper pair box (SCB), a mesoscopic superconducting device that has been successfully developed at JPL for applications in quantum computing. This concept allows for frequency multiplexing of a large number of pixels using a single RF line, and does not require individual bias of each pixel. The QCD is ideal for the sensitive spectrographs considered for upcoming cold space telescopes, such as BLISS for SPICA in the coming decade, and for the more ambitious instruments for the SAFIR / CALISTO and SPIRIT / SPECS missions envisioned for the 2020 decade. These missions require large detector arrays (> 10,000 elements) which are limited by astrophysical background noise, corresponding to a noise-equivalent power (NEP) as low as 2x10-20 W / Hz1/2. Given its intrinsic response time, the QCD could also be used for energy-resolved visible photon detection, with estimated energy resolution > 100, enabling imaging low-resolution spectroscopy with an array of detectors.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا