ترغب بنشر مسار تعليمي؟ اضغط هنا

Magnetic Field Fingerprinting of Integrated Circuit Activity with a Quantum Diamond Microscope

189   0   0.0 ( 0 )
 نشر من قبل Matthew Turner
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Current density distributions in active integrated circuits (ICs) result in patterns of magnetic fields that contain structural and functional information about the IC. Magnetic fields pass through standard materials used by the semiconductor industry and provide a powerful means to fingerprint IC activity for security and failure analysis applications. Here, we demonstrate high spatial resolution, wide field-of-view, vector magnetic field imaging of static (DC) magnetic field emanations from an IC in different active states using a Quantum Diamond Microscope (QDM). The QDM employs a dense layer of fluorescent nitrogen-vacancy (NV) quantum defects near the surface of a transparent diamond substrate placed on the IC to image magnetic fields. We show that QDM imaging achieves simultaneous $sim10$ $mu$m resolution of all three vector magnetic field components over the 3.7 mm $times$ 3.7 mm field-of-view of the diamond. We study activity arising from spatially-dependent current flow in both intact and decapsulated field-programmable gate arrays (FPGAs); and find that QDM images can determine pre-programmed IC active states with high fidelity using machine-learning classification methods.

قيم البحث

اقرأ أيضاً

Devices relying on microwave circuitry form a cornerstone of many classical and emerging quantum technologies. A capability to provide in-situ, noninvasive and direct imaging of the microwave fields above such devices would be a powerful tool for the ir function and failure analysis. In this work, we build on recent achievements in magnetometry using ensembles of nitrogen vacancy centres in diamond, to present a widefield microwave microscope with few-micron resolution over a millimeter-scale field of view, 130nT/sqrt-Hz microwave amplitude sensitivity, a dynamic range of 48 dB, and sub-ms temporal resolution. We use our microscope to image the microwave field a few microns above a range of microwave circuitry components, and to characterise a novel atom chip design. Our results open the way to high-throughput characterisation and debugging of complex, multi-component microwave devices, including real-time exploration of device operation.
We introduce a double quantum (DQ) 4-Ramsey measurement protocol that enables wide-field magnetic imaging using nitrogen vacancy (NV) centers in diamond, with enhanced homogeneity of the magnetic sensitivity relative to conventional single quantum (S Q) techniques. The DQ 4-Ramsey protocol employs microwave-phase alternation across four consecutive Ramsey (4-Ramsey) measurements to isolate the desired DQ magnetic signal from any residual SQ signal induced by microwave pulse errors. In a demonstration experiment employing a 1-$mu$m-thick NV layer in a macroscopic diamond chip, the DQ 4-Ramsey protocol provides volume-normalized DC magnetic sensitivity of $eta^text{V}=34,$nTHz$^{-1/2} mu$m$^{3/2}$ across a $125,mu$m$ ,times,125,mu $m field of view, with about 5$times$ less spatial variation in sensitivity across the field of view compared to a SQ measurement. The improved robustness and magnetic sensitivity homogeneity of the DQ 4-Ramsey protocol enable imaging of dynamic, broadband magnetic sources such as integrated circuits and electrically-active cells.
The optical selection rules in epitaxial quantum dots are strongly influenced by the orientation of their natural quantization axis, which is usually parallel to the growth direction. This configuration is well suited for vertically emitting devices, but not for planar photonic circuits because of the poorly controlled orientation of the transition dipoles in the growth plane. Here we show that the quantization axis of gallium arsenide dots can be flipped into the growth plane via moderate in plane uniaxial stress. By using piezoelectric strain actuators featuring strain-amplification we study the evolution of the selection rules and excitonic fine-structure in a regime, in which quantum confinement can be regarded as a perturbation compared to strain in determining the symmetry properties of the system. The experimental and computational results suggest that uniaxial stress, may be the right tool to obtain quantum light sources with ideally oriented transition dipoles and enhanced oscillator strengths for integrated quantum photonics.
Quantum sensors based on nitrogen-vacancy centers in diamond have emerged as a promising detection modality for nuclear magnetic resonance (NMR) spectroscopy owing to their micron-scale detection volume and non-inductive based detection. A remaining challenge is to realize sufficiently high spectral resolution and concentration sensitivity for multidimensional NMR analysis of picoliter sample volumes. Here, we address this challenge by spatially separating the polarization and detection phases of the experiment in a microfluidic platform. We realize a spectral resolution of 0.65 +/- 0.05 Hz, an order-of-magnitude improvement over previous diamond NMR studies. We use the platform to perform two-dimensional correlation spectroscopy of liquid analytes within an effective ~20 picoliter detection volume. The use of diamond quantum sensors as in-line microfluidic NMR detectors is a significant step towards applications in mass-limited chemical analysis and single cell biology.
We provide an overview of the experimental techniques, measurement modalities, and diverse applications of the Quantum Diamond Microscope (QDM). The QDM employs a dense layer of fluorescent nitrogen-vacancy (NV) color centers near the surface of a tr ansparent diamond chip on which a sample of interest is placed. NV electronic spins are coherently probed with microwaves and optically initialized and read out to provide spatially resolved maps of local magnetic fields. NV fluorescence is measured simultaneously across the diamond surface, resulting in a wide-field, two-dimensional magnetic field image with adjustable spatial pixel size set by the parameters of the imaging system. NV measurement protocols are tailored for imaging of broadband and narrowband fields, from DC to GHz frequencies. Here we summarize the physical principles common to diverse implementations of the QDM and review example applications of the technology in geoscience, biology, and materials science.