ترغب بنشر مسار تعليمي؟ اضغط هنا

Neutron Guide Building Instruments of the Brazilian Multipurpose Reactor (RMB) Project

51   0   0.0 ( 0 )
 نشر من قبل Luiz P. de Oliveira
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A growing community of scientists has been using neutrons in the most diverse areas of science. In order to meet the researchers demand in the areas of physics, chemistry, materials sciences, engineering, cultural heritage, biology and earth sciences, the Brazilian Multipurpose Reactor (RMB) will provide 3 thermal guides and 3 cold guides, with the installation of several instruments for materials characterization. In this study, we present a standard design requirement of two primordial instruments, namely Sabia and Araponga. They are, respectively, cold and thermal neutron instruments and correspond to a Small-Angle Neutron Scattering (SANS) and High-Resolution Powder Neutron Diffractometer (HRPND) to be installed in the Neutron Guide Building (N02) of RMB. To provide adequate flux for both instruments, we propose here an initial investigation of the use of simple and split guides to transport neutron beams to two different instruments on the same guide. For this purpose, we use Monte Carlo simulations utilizing McStas software to check the efficiency of thermal neutron transport for different basic configuration and sources. By considering these results, it is possible to conclude that the split guide configuration is, in most cases, more efficient than cases that use transmitted neutron beams independently of source. We also verify that the employment of different coating indexes for concave and convex surfaces on curved guides is crucial, at least on simulated cases, to optimise neutron flux (intensity and divergence) and diminish facility installation cost.

قيم البحث

اقرأ أيضاً

Neutron transport along guides is governed by the Liouville theorem and the technology involved has advanced in recent decades. Computer simulations have proven to be useful tools in the design and conception of neutron guide systems in facilities. I n this study, we use a Monte Carlo method to perform simulations for an S-shaped neutron guide with different dimensions for a Small-Angle Neutron Scattering (SANS) instrument, through the MCSTAS software. A wavelength cutoff is observed and shown to be dependent on the geometrical parameters of the guide. Results for the neutron flux at sample position are presented and a greater sensitivity of cutoffs concerning the curvatures of the guides than to their lengths is noticed. Our results are in agreement with those obtained from the Acceptance Diagram method and we analyze the beam divergence behavior along the S-shaped guide.
The Neutrinos Angra Experiment is a water-based Cherenkov detector located in the Angra dos Reis nuclear power plant. The experiment has completed a major step by finishing the commissioning of the detector and the data acquisition system at the expe rimental site. The experiment was designed to detect the electron antineutrinos produced by the nuclear reactor with the main purpose to demonstrate the feasibility of monitoring the reactor activity using an antineutrino detector. This effort is within the context of the International Atomic Energy Agency (IAEA) program to identify potential and novel technologies that can be applied for non-proliferation safeguards. Challenges, such as operating at the surface, therefore with huge noise rates, and the need to build very sensitive but small-scale detectors, make the Angra experiment an excellent platform for developing the application itself, as well as acquiring expertise in new technologies and analysis methods. In this report, we describe the main detector features and the electronics chain (front-end and data acquisition). We also report preliminary physics results obtained from the commissioning phase data. Finally, we address conclusions regarding the future perspectives to keep this program active, due to its importance in the insertion of Latin-American scientists and engineers in a world-scale cutting edge scientific program.
92 - J. Karch , Yu. Sobolev , M. Beck 2013
The performance of the solid deuterium ultra-cold neutron source at the pulsed reactor TRIGA Mainz with a maximum peak energy of 10 MJ is described. The solid deuterium converter with a volume of V=160 cm3 (8 mol), which is exposed to a thermal neutr on fluence of 4.5x10^13 n/cm2, delivers up to 550 000 UCN per pulse outside of the biological shield at the experimental area. UCN densities of ~ 10/cm3 are obtained in stainless steel bottles of V ~ 10 L resulting in a storage efficiency of ~20%. The measured UCN yields compare well with the predictions from a Monte Carlo simulation developed to model the source and to optimize its performance for the upcoming upgrade of the TRIGA Mainz into a user facility for UCN physics.
A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a $^6$Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of $10^8$ n/cm$^2$s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of $10^6$ n/cm$^2$s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10$^9$ n/cm$^2$s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4.
We report a novel correlated background in the antineutrino detection using the inverse beta decay reaction. Spontaneous fissions and $(alpha,n)$ reactions in peripheral materials of the antineutrino detector, such as borosilicate glass of photomulti pliers, produce fast neutrons and prompt gamma rays. If the shielding from the material to the detector target were not thick enough, neutrons and gammas could enter the target volume and mimic antineutrino signals. This paper revisits the yields and energy spectra of neutrons produced in B$(alpha,n)$N and F$(alpha,n)$Na reactions. A Geant4 based simulation has been carried out using a simplified detector geometry for the present generation reactor neutrino experiments. The background rates in these experiments are estimated. If this background was not taken into account, the value of the neutrino mixing angle $sin^22theta_{13}$ would be underestimated. We recommend that Daya Bay, RENO, Double Chooz, and JUNO, carefully examine the masses and radiopurity levels of detector materials that are close to the target and rich in boron and fluorine.