Stability and Accuracy Assessment based Large-Signal Order Reduction of Microgrids

89   0   0.0 ( 0 )
 نشر من قبل Zixiao Ma
 تاريخ النشر 2019
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper aims to propose a novel large-signal order reduction (LSOR) approach for microgrids (MG) by embedding a stability and accuracy assessment theorem. Different from the existing order reduction methods, the proposed approach prevails mainly in two aspects. Firstly, the dynamic stability of full-order MG models can be assessed by only leveraging their derived reduced-order models and boundary layer models with our method. Specially, when the reduced-order system is input-to-state stable and the boundary layer system is uniformly globally asymptotically stable, the original MGs system can be proved to be stable under several common growth conditions. Secondly, a set of accuracy assessment criterion is developed and embedded into a tailored feedback mechanism to guarantee the accuracy of derived reduced model. It is proved that the errors between solutions of reduced and original models are bounded and convergent under such conditions. Strict mathematical proof for the proposed stability and accuracy assessment theorem is provided. The proposed LSOR method is generic and can be applied to arbitrary dynamic systems. Multiple case studies are conducted on MG systems to show the effectiveness of proposed approach.



قيم البحث

اقرأ أيضاً

Proper modeling of inverter-based microgrids is crucial for accurate assessment of stability boundaries. It has been recently realized that the stability conditions for such microgrids are significantly different from those known for large- scale pow er systems. While detailed models are available, they are both computationally expensive and can not provide the insight into the instability mechanisms and factors. In this paper, a computationally efficient and accurate reduced-order model is proposed for modeling the inverter-based microgrids. The main factors affecting microgrid stability are analyzed using the developed reduced-order model and are shown to be unique for the microgrid-based network, which has no direct analogy to large-scale power systems. Particularly, it has been discovered that the stability limits for the conventional droop-based system (omega - P/V - Q) are determined by the ratio of inverter rating to network capacity, leading to a smaller stability region for microgrids with shorter lines. The theoretical derivation has been provided to verify the above investigation based on both the simplified and generalized network configurations. More impor- tantly, the proposed reduced-order model not only maintains the modeling accuracy but also enhances the computation efficiency. Finally, the results are verified with the detailed model via both frequency and time domain analyses.
111 - Hang Shuai , Member , IEEE 2021
The uncertainties from distributed energy resources (DERs) bring significant challenges to the real-time operation of microgrids. In addition, due to the nonlinear constraints in the AC power flow equation and the nonlinearity of the battery storage model, etc., the optimization of the microgrid is a mixed-integer nonlinear programming (MINLP) problem. It is challenging to solve this kind of stochastic nonlinear optimization problem. To address the challenge, this paper proposes a deep reinforcement learning (DRL) based optimization strategy for the real-time operation of the microgrid. Specifically, we construct the detailed operation model for the microgrid and formulate the real-time optimization problem as a Markov Decision Process (MDP). Then, a double deep Q network (DDQN) based architecture is designed to solve the MINLP problem. The proposed approach can learn a near-optimal strategy only from the historical data. The effectiveness of the proposed algorithm is validated by the simulations on a 10-bus microgrid system and a modified IEEE 69-bus microgrid system. The numerical simulation results demonstrate that the proposed approach outperforms several existing methods.
This paper investigates the impact of Kron reduction on the performance of numerical methods applied to the analysis of unbalanced polyphase power systems. Specifically, this paper focuses on power-flow study, state estimation, and voltage stability assessment. For these applications, the standard Newton-Raphson method, linear weighted-least-squares regression, and homotopy continuation method are used, respectively. The performance of the said numerical methods is assessed in a series of simulations, in which the zero-injection nodes of a test system are successively eliminated through Kron reduction.
This paper presents a method for controlling the voltage of inverter-based Microgrids by proposing a new scale-free distributed cooperative controller. The communication network is modeled by a general time-varying graph which enhances the resilience of the proposed protocol against communication link failure, data packet loss, and fast plug and play operation in the presence of arbitrarily communication delays. The proposed scale-free distributed cooperative controller is independent of any information about the communication system and the size of the network (i.e., the number of distributed generators). The stability analysis of the proposed protocol is provided. The proposed method is simulated on the CIGRE medium voltage Microgrid test system. The simulation results demonstrate the feasibility of the proposed scale-free distributed nonlinear protocol for regulating the voltage of Microgrids in presence of communication failures, data packet loss, noise, and degradation.
83 - Cunlai Pu , Pang Wu 2019
In modern power grids, a local failure or attack can trigger catastrophic cascading failures, which make it challenging to assess the attack vulnerability of power grids. In this Brief, we define the $K$-link attack problem and study the attack vulne rability of power grids under cascading failures. Particularly, we propose a link centrality measure based on both topological and electrical properties of power grids. According to this centrality, we propose a greedy attack algorithm and an optimal attack algorithm. Simulation results on standard IEEE bus test data show that the optimal attack is better than the greedy attack and the traditional PSO-based attack in fracturing power grids. Moreover, the greedy attack has smaller computational complexity than the optimal attack and the PSO-based attack with an adequate attack efficiency. Our work helps to understand the vulnerability of power grids and provides some clues for securing power grids.