ترغب بنشر مسار تعليمي؟ اضغط هنا

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

122   0   0.0 ( 0 )
 نشر من قبل Yang Li
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.



قيم البحث

اقرأ أيضاً

70 - X.Y. Ji , P. Cao , T. Yu 2018
the main physics goal for Back-n white neutron facility at China Spallation Neutron Source (CSNS) is to measure nuclear data. The energy of neutrons is one of the most important parameters for measuring nuclear data. Method of time of flight (TOF) is used to obtain the energy of neutrons. The time when proton bunches hit the thick tungsten target is considered as the start point of TOF. T0 signal, generated from the CSNS accelerator, represents this start time. Besides, the T0 signal is also used as the gate control signal that triggers the readout electronics. Obviously, the timing precision of T0 directly affects the measurement precision of TOF and controls the running or readout electronics. In this paper, the T0 fan-out for Back-n white neutron facility at CSNS is proposed. The T0 signal travelling from the CSNS accelerator is fanned out to the two underground experiment stations respectively over long cables. To guarantee the timing precision, T0 signal is conditioned with good signal edge. Furthermore, techniques of signal pre-emphasizing and equalizing are used to improve signal quality after T0 being transmitted over long cables with about 100 m length. Experiments show that the T0 fan-out works well, the T0 signal transmitted over 100 m remains a good time resolution with a standard deviation of 25 ps. It absolutely meets the required accuracy of the measurement of TOF.
Back-streaming neutrons from the spallation target of the China Spallation Neutron Source (CSNS) that emit through the incoming proton channel were exploited to build a white neutron beam facility (the so-called Back-n white neutron source), which wa s completed in March 2018. The Back-n neutron beam is very intense, at approximately 2*10^7 n/cm^2/s at 55 m from the target, and has a nominal proton beam with a power of 100 kW in the CSNS-I phase and a kinetic energy of 1.6 GeV and a thick tungsten target in multiple slices with modest moderation from the cooling water through the slices. In addition, the excellent energy spectrum spanning from 0.5 eV to 200 MeV, and a good time resolution related to the time-of-flight measurements make it a typical white neutron source for nuclear data measurements; its overall performance is among that of the best white neutron sources in the world. Equipped with advanced spectrometers, detectors, and application utilities, the Back-n facility can serve wide applications, with a focus on neutron-induced cross-section measurements. This article presents an overview of the neutron beam characteristics, the experimental setups, and the ongoing applications at Back-n.
The back-streaming white neutron source (Back-n) is a comprehensive neutron experimental platform for nuclear data measurement, nuclear astrophysics, neutron irradiation, detector calibration, etc. In order to meet a variety of experimental requireme nts, an attempt of various combinations of collimators has been made for the current collimation system. The basic parameters such as beam flux and beam spot characteristics under different beam operation modes have been studied. According to the change of the CSNS proton beam operation mode, the influence of different proton beam spots on the Back-n beam is also studied. The study finds that some beam modes with new collimator combinations can meet the experimental requirements and greatly shorten the experimental time. In addition, we have found a parameterized formula for the uniform beam spot of the high-power proton beam based on the beam monitor data, which provides a more accurate proton-beam source term for future white neutron beam physics and application researches.
65 - T. Yu , P. Cao , X.Y. Ji 2018
Back-n is a white neutron experimental facility at China Spallation Neutron Source (CSNS). The time structure of the primary proton beam make it fully applicable to use TOF (time-of-flight) method for neutron energy measuring. We implement the electr onics of TOF measurement on the general-purpose readout electronics designed for all of the seven detectors in Back-n. The electronics is based on PXIe (Peripheral Component Interconnect Express eXtensions for Instrumentation) platform, which is composed of FDM (Field Digitizer Modules), TCM (Trigger and Clock Module), and SCM (Signal Conditioning Module). T0 signal synchronous to the CSNS accelerator represents the neutron emission from the target. It is the start of time stamp. The trigger and clock module (TCM) receives, synchronizes and distributes the T0 signal to each FDM based on the PXIe backplane bus. Meantime, detector signals after being conditioned are fed into FDMs for waveform digitizing. First sample point of the signal is the stop of time stamp. According to the start, stop time stamp and the time of signal over threshold, the total TOF can be obtained. FPGA-based (Field Programmable Gate Array) TDC is implemented on TCM to accurately acquire the time interval between the asynchronous T0 signal and the global synchronous clock phase. There is also an FPGA-based TDC on FDM to accurately acquire the time interval between T0 arriving at FDM and the first sample point of the detector signal, the over threshold time of signal is obtained offline. This method for TOF measurement is efficient and not needed for additional modules. Test result shows the accuracy of TOF is sub-nanosecond and can meet the requirement for Back-n at CSNS.
173 - J. Lopez , K. Terao , J.M. Conrad 2011
This paper describes a novel directional neutron detector prototype. The low pressure time projection chamber uses a mix of helium and CF4 gases. The detector reconstructs the energy and angular distribution of fast neutron recoils. This paper report s results of energy calibration using an alpha source and angular reconstruction studies using a collimated neutron source. The best performance is obtained with a 12.5% CF4 gas mixture. At low energies the target for fast neutrons transitions is primarily helium, while at higher energies, the fluorine contributes as a target. The reconstruction efficiency is both energy and target dependent. For neutrons with energies less than 20 MeV, the reconstruction efficiency is ~40% for fluorine recoils and ~60% for helium recoils.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا