ترغب بنشر مسار تعليمي؟ اضغط هنا

Phase modulation in storage-ring RF systems

146   0   0.0 ( 0 )
 نشر من قبل Dmitry Teytelman
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Dmitry Teytelman




اسأل ChatGPT حول البحث

This paper presents a conceptual approach to phase modulation of the cavity field in storage ring RF systems. An implementation of the concept on Dimtel low-level RF controllers is also presented. The method is illustrated with the test results from a cavity simulator, as well as an electron storage ring KARA.



قيم البحث

اقرأ أيضاً

We have commissioned the digital Low Level RF (LLRF) system for storage ring RF at Advanced Light Source at Lawrence Berkeley National Lab (LBNL). The system is composed of 42 synchronous sampling channels for feedback control, diagnostics, and inter locks. The closed loop RF amplitude and phase stability is measured as < 0.1% and < 0.1 degree respectively, and the real-time machine protection interlock latency is measured < 2.5 microsecond. We have also developed PLC-FPGA-EPICS interfaces to support system configurations between hybrid operation modes using two klystrons driving two RF cavities at 500MHz resonance frequency. The deployed LLRF system has been operating since March 2017.
This letter reports the successful use of feedback from a spin polarization measurement to the revolution frequency of a 0.97 GeV/$c$ bunched and polarized deuteron beam in the Cooler Synchrotron (COSY) storage ring in order to control both the prece ssion rate ($approx 121$ kHz) and the phase of the horizontal polarization component. Real time synchronization with a radio frequency (rf) solenoid made possible the rotation of the polarization out of the horizontal plane, yielding a demonstration of the feedback method to manipulate the polarization. In particular, the rotation rate shows a sinusoidal function of the horizontal polarization phase (relative to the rf solenoid), which was controlled to within a one standard deviation range of $sigma = 0.21$ rad. The minimum possible adjustment was 3.7 mHz out of a revolution frequency of 753 kHz, which changes the precession rate by 26 mrad/s. Such a capability meets a requirement for the use of storage rings to look for an intrinsic electric dipole moment of charged particles.
121 - C. M. Bhat 2015
In this Letter, I report on a novel scheme for beam stacking without any beam emittance dilution using a barrier rf system in synchrotrons. The general principle of the scheme called longitudinal phase-space coating, validation of the concept via mul ti-particle beam dynamics simulations applied to the Fermilab Recycler, and its experimental demonstration are presented. In addition, it has been shown and illustrated that the rf gymnastics involved in this scheme can be used in measuring the incoherent synchrotron tune spectrum of the beam in barrier buckets and in producing a clean hollow beam in longitudinal phase space. The method of beam stacking in synchrotrons presented here is the first of its kind.
This paper reports the first simultaneous measurement of the horizontal and vertical components of the polarization vector in a storage ring under the influence of a radio frequency (rf) solenoid. The experiments were performed at the Cooler Synchrot ron COSY in Julich using a vector polarized, bunched $0.97,textrm{GeV/c}$ deuteron beam. Using the new spin feedback system, we set the initial phase difference between the solenoid field and the precession of the polarization vector to a predefined value. The feedback system was then switched off, allowing the phase difference to change over time, and the solenoid was switched on to rotate the polarization vector. We observed an oscillation of the vertical polarization component and the phase difference. The oscillations can be described using an analytical model. The results of this experiment also apply to other rf devices with horizontal magnetic fields, such as Wien filters. The precise manipulation of particle spins in storage rings is a prerequisite for measuring the electric dipole moment (EDM) of charged particles.
This work demonstrates that two systematic errors, coherent betatron oscillations (CBO) and muon losses can be reduced through application of radio frequency (RF) electric fields, which ultimately increases the sensitivity of the muon $g-2$ experimen ts. As the ensemble of polarized muons goes around a weak focusing storage ring, their spin precesses, and when they decay through the weak interaction, $mu^+ rightarrow e^+ u_e bar{ u_mu}$, the decay positrons are detected by electromagnetic calorimeters. In addition to the expected exponential decay in the positron time spectrum, the weak decay asymmetry causes a modulation in the number of positrons in a selected energy range at the difference frequency between the spin and cyclotron frequencies, $omega_text{a}$. This frequency is directly proportional to the magnetic anomaly $a_mu =(g-2)/2$, where $g$ is the g-factor of the muon, which is slightly greater than 2. The detector acceptance depends on the radial position of the muon decay, so the CBO of the muon bunch following injection into the storage ring modulate the measured muon signal with the frequency $omega_text{CBO}$. In addition, the muon populations at the edge of the beam hit the walls of the vacuum chamber before decaying, which also affects the signal. Thus, reduction of CBO and unwanted muon loss increases the $a_mu$ measurement sensitivity. Numerical and experimental studies with RF electric fields yield more than a magnitude reduction of the CBO, with muon losses comparable to the conventional method.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا