ترغب بنشر مسار تعليمي؟ اضغط هنا

Conceptual design and first results for a neutron detector with interaction localization capabilities

265   0   0.0 ( 0 )
 نشر من قبل Joseph Heideman
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A new high-precision detector for studying neutrons from beta-delayed neutron emission and direct reaction studies is proposed. The Neutron dEtector with Xn Tracking (NEXT) array is designed to maintain high intrinsic neutron detection efficiency while reducing uncertainties in neutron energy measurements. A single NEXT module is composed of thin segments of plastic scintillator, each optically separated, capable of neutron-gamma discrimination. Each segmented module is coupled to position sensitive photodetectors enabling the high-precision determination of neutron time of arrival and interaction position within the active volume. A design study has been conducted based on simulations and experimental tests leading to the construction of prototype units. First results from measurements using a $^{252}$Cf neutron source and accelerator-produced monoenergetic neutrons are presented.



قيم البحث

اقرأ أيضاً

178 - R. Ball 2014
A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6 to 2.5 volt amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency of greater than 95% is calculated, for operation of the detector over a 100V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3 to 4 orders of magnitude lower than the rate with the cell illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm.
BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, $beta$-particles, $gamma$-rays and $beta$-delayed neutrons. The whole detection setup involves t he Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-tubes array, aiming at the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected parameters of merit, namely, average neutron detection efficiency and efficiency flatness, as a function of a reduced number of geometric variables. The response of the detection system itself, for each configuration, is obtained from a systematic MC-simulation implemented realistically in Geant4. This approach has been found to be particularly useful. On the one hand, due to the different types and large number of 3He-tubes involved and, on the other hand, due to the additional constraints introduced by the ancillary detectors for charged particles and gamma-rays. Empowered by the robustness of the algorithm, we have been able to design a versatile detection system, which can be easily re-arranged into a compact mode in order to maximize the neutron detection performance, at the cost of the gamma-ray sensitivity. In summary, we have designed a system which shows, for neutron energies up to 1(5) MeV, a rather flat and high average efficiency of 68.6%(64%) and 75.7%(71%) for the hybrid and compact modes, respectively. The performance of the BRIKEN system has been also quantified realistically by means of MC-simulations made with different neutron energy distributions.
68 - M. K. Singh , A. Sonay , M. Deniz 2016
We report the performance and characterization of a custom-built hybrid detector consisting of BC501A liquid scintillator for fast neutrons and BC702 scintillator for thermal neutrons. The calibration and the resolution of the BC501A liquid scintilla tor detector are performed. The event identification via Pulse Shape Discrimination (PSD) technique is developed in order to distinguish gamma, fast and thermal neutrons. Monte Carlo simulation packages are developed in GEANT4 to obtain actual neutron energy spectrum from the measured recoil spectrum. The developed methods are tested by reconstruction of 241AmBe(alpha, n) neutron spectrum.
Mu2e at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current worlds best limits for this process. The experiments sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the conceptual design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-1 approval, which was granted July 11, 2012.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا