ترغب بنشر مسار تعليمي؟ اضغط هنا

A 2D scintillator based proton detector for HRR experiments

73   0   0.0 ( 0 )
 نشر من قبل Luca Volpe
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present a scintillator based detector able to measure both spatial and energy information at High repetition rate (HRR) with a relatively simple design. It has been built at the Center of Pulsed Laser (CLPU) in Salamanca and tested in the proton accelerator at the Centro de Micro-Analisis de Materiales (CMAM) in Madrid. The detector has been demonstrated to work in HRR mode by reproducing the performance of the radiochromic film detector. It represents a new class of on-line detectors for Laser-plasma physics experiments in the new emerging High Power and HRR laser systems.

قيم البحث

اقرأ أيضاً

We have constructed and tested a novel plastic-scintillator-based solid-state active proton target for use in nuclear spectroscopic studies with nuclear reactions induced by an ion beam in inverse kinematics. The active target system, named Stack Str ucture Solid organic Scintillator Active Target (S4AT), consists of five layers of plastic scintillators, each with a 1-mm thickness. To determine the reaction point in the thickness direction, we exploit the difference in the energy losses due to the beam particle and the charged reaction product(s) in the scintillator material. S4AT offers the prospect of a relatively thick target while maintaining a good energy resolution. By considering the relative energy loss between different layers, the energy loss due to unreacted beam particles can be eliminated. Such procedure, made possible by the multi-layer structure, is essential to eliminate the effect of unreacted accompanying beam particles, thus enabling its operation at a moderate beam intensity of up to a few Mcps. We evaluated the performance of S4AT by measuring the elastic proton-proton scattering using a 70-MeV proton beam at Cyclotron and Radioisotope Center (CYRIC), Tohoku University.
A simple device for determining the azimuthal location of a source of gamma radiation, using ideas from astrophysical gamma-ray burst detection, is described. A compact and robust detector built from eight identical modules, each comprising a plate o f CsI(Tl) scintillator coupled to a photomultiplier tube, can locate a point source of gamma rays with degree-scale precision by comparing the count rates in the different modules. Sensitivity to uniform environmental background is minimal.
For radiography applications using fast neutrons simultaneously with gammas we have developed a detector with 16 stilbene crystals in a 4$times$4 2D array with a 5~mm pitch and a depth of 25~mm. The crystal array is read out by Silicon photomultiplie rs and custom signal processing electronics. The detector prototype was tested using a custom D-D fast neutron generator at the Paul Scherrer Institute. By applying a pulse shape discrimination algorithm the detector is able to detect and distinguish fast neutrons and gammas simultaneously. Various attenuating samples placed between the source and detector with different materials and thicknesses were tested and the measured macroscopic fast neutron cross sections were compared to what was expected. Deviations were studied with the help of detailed Geant4 simulations. The detection efficiency for D-D fast neutrons was measured to be around 10%.
A new muon and K_Long detector based on scintillators will be used for the endcap and inner barrel regions in the Belle II experiment, currently under construction. The increased luminosity of the e+e- SuperKEKB collider entails challenging detector requirements. We demonstrate that relatively inexpensive polystyrene scintillator stips with wave length shifting fibers ensure a sufficient light yield at the Silcon PhotoMultiplier (SiPM) photodetector, are robust and provide improved physics performance for the Belle II experiment compared to its predecessor, Belle.
74 - M.S. Yang , Z.Y. Yu , J. Cao 2018
Linear alkylbenzene has been recently used as the solvent of liquid scintillator by several neutrino experiments. The energy quenching effect of a linear alkylbenzene based liquid scintillator is studied in this paper with a 14 MeV D-T compact neutro n generator, to improve the energy non-linearity modelling of this kind of detectors. The recoiled proton in the liquid scintillator has a kinetic energy ranging from 0.5 MeV to 13 MeV. The data is used to extract the parameters of the Birks law, an empirical model to describe the energy quenching effect of the liquid scintillator.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا