ترغب بنشر مسار تعليمي؟ اضغط هنا

Spin dependent transport characterization in metallic lateral spin valves using 1D and 3D modeling

79   0   0.0 ( 0 )
 نشر من قبل Laurent Vila
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We present the analysis of the spin signals obtained in NiFe based metallic lateral spin valves. We exploit the spin dependent diffusive equations in both the conventional 1D analytic modeling as well as in 3D Finite Element Method simulations. Both approaches are used for extracting the spin diffusion length $l_{sf}^{N}$ and the effective spin polarization $P_{eff}$ in Py/Al, Py/Cu and Py/Au based lateral nano-structures at both $300,K$ and $77,K$. Both the analytic modeling and 3D Finite Element Method simulations give consistent results. Combination of both models provides a powerful tool for reliable spin transport characterization in all metallic spin valves and gives an insight into the spin/charge current and spin accumulations 3D distributions in these devices. We provide the necessary ingredients to develop the 3D finite element modeling of diffusive spin transport.


قيم البحث

اقرأ أيضاً

The spin absorption process in a ferromagnetic material depends on the spin orientation relativelyto the magnetization. Using a ferromagnet to absorb the pure spin current created within a lateralspin-valve, we evidence and quantify a sizeable orient ation dependence of the spin absorption inCo, CoFe and NiFe. These experiments allow determining the spin-mixing conductance, an elusivebut fundamental parameter of the spin-dependent transport. We show that the obtained valuescannot be understood within a model considering only the Larmor, transverse decoherence and spindiffusion lengths, and rather suggest that the spin-mixing conductance is actually limited by theSharvin conductance.
We performed non-local electrical measurements of a series of Py/Cu lateral spin valve devices with different Cu thicknesses. We show that both the spin diffusion length of Cu and the apparent spin polarization of Py increase with Cu thickness. By fi tting the results to a modified spin-diffusion model, we show that the spin diffusion length of Cu is dominated by spin-flip scattering at the surface. In addition, the dependence of spin polarization of Py on Cu thickness is due to a strong spin-flip scattering at the Py/Cu interface.
A longstanding goal of research in semiconductor spintronics is the ability to inject, modulate, and detect electron spin in a single device. A simple prototype consists of a lateral semiconductor channel with two ferromagnetic contacts, one of which serves as a source of spin-polarized electrons and the other as a detector. Based on work in analogous metallic systems, two important criteria have emerged for demonstrating electrical detection of spin transport. The first is the measurement of a non-equilibrium spin population using a non-local ferromagnetic detector through which no charge current flows. The potential at the detection electrode should be sensitive to the relative magnetizations of the detector and the source electrodes, a property referred to as the spin-valve effect. A second and more rigorous test is the existence of a Hanle effect, which is the modulation and suppression of the spin valve signal due to precession and dephasing in a transverse magnetic field. Here we report on the observation of both the spin valve and Hanle effects in lateral devices consisting of epitaxial Fe Schottky tunnel barrier contacts on an n-doped GaAs channel. The dependence on transverse magnetic field, temperature, and contact separation are in good agreement with a model incorporating spin drift and diffusion. Spin transport is detected for both directions of current flow through the source electrode. The sign of the electrical detection signal is found to vary with the injection current and is correlated with the spin polarization in the GaAs channel determined by optical measurements. These results therefore demonstrate a fully electrical scheme for spin injection, transport, and detection in a lateral semiconductor device.
108 - Y. Fukuma , L. Wang , H. Idzuchi 2011
The nonlocal spin injection in lateral spin valves is highly expected to be an effective method to generate a pure spin current for potential spintronic application. However, the spin valve voltage, which decides the magnitude of the spin current flo wing into an additional ferromagnetic wire, is typically of the order of 1 {mu}V. Here we show that lateral spin valves with low resistive NiFe/MgO/Ag junctions enable the efficient spin injection with high applied current density, which leads to the spin valve voltage increased hundredfold. Hanle effect measurements demonstrate a long-distance collective 2-pi spin precession along a 6 {mu}m long Ag wire. These results suggest a route to faster and manipulable spin transport for the development of pure spin current based memory, logic and sensing devices.
123 - G. Zahnd , L. Vila , T. V. Pham 2015
Spin injection and detection in Co60Fe40-based all-metallic lateral spin-valves have been studied at both room and low temperatures. The obtained spin signals amplitudes have been compared to that of identical Ni80Fe20-based devices. The replacement of Ni80Fe20 by CoFe allows increasing the spin signal amplitude by up to one order of magnitude, thus reaching 50 m{Omega} at room temperature. The spin signal dependence with the distance between the ferromagnetic electrodes has been analyzed using both a 1D spin transport model and finite elements method simulations. The enhancement of the spin signal amplitude when using CoFe electrodes can be explained by a higher effective polarization.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا