Robust and homogeneous lipid suppression is mandatory for coronary magnetic resonance angiography (MRA) since coronary arteries are commonly embedded in fat. However, effective large volume lipid suppression becomes challenging when performing radial whole-heart coronary MRA and the problem may even be exacerbated at increasing magnetic field strengths. Incomplete fat suppression also generates artifacts, and may affect advanced motion correction methods. The aim was to evaluate a recently reported lipid insensitive MRI method for self-navigated coronary MRA at 3T. Lipid insensitive binomial off resonant excitation (LIBRE) radiofrequency (RF) excitation pulses were included into a self-navigated 3D radial GRE coronary MRA sequence at 3T. LIBRE was compared against conventional fat saturation (FS) and binomial 1-180{deg}-1 water excitation (WE). First, fat suppression of all techniques was numerically characterized using Matlab and experimentally validated in phantoms and in legs of human volunteers. Subsequently, free-breathing self-navigated coronary MRA was performed using the LIBRE pulse as well as FS and WE in ten volunteers. Results obtained in the simulations were confirmed by the experimental validations as LIBRE enabled near complete fat suppression for 3D radial imaging in vitro and in vivo. For self-navigated whole-heart coronary MRA at 3T, fat SNR was significantly attenuated using LIBRE compared with conventional FS. LIBRE increased the RCA vessel sharpness significantly (37 +/- 9% (LIBRE) vs. 29 +/- 8% (FS) and 30 +/- 8% (WE), both p<0.05) and led to a significant increase in the measured RCA vessel length to (83 +/- 31 mm (LIBRE) vs. 56 +/- 12 mm (FS) and 59 +/- 27 (WE) p<0.05). LIBRE enables robust large volume fat suppression and significantly improves coronary artery image quality at 3T compared to the use of conventional fat suppression and water excitation.
Purpose: To develop a robust and flexible low power water excitation pulse that enables effective fat suppression at high magnetic field strength. Methods: A water excitation method that uses spatially non-selective pulses was optimized in numerical
Background: RSN whole-heart CMRA is a technique that estimates and corrects for respiratory motion. However, RSN has been limited to a 1D rigid correction which is often insufficient for patients with complex respiratory patterns. The goal of this wo
Vessel stenosis is a major risk factor in cardiovascular diseases (CVD). To analyze the degree of vessel stenosis for supporting the treatment management, extraction of coronary artery area from Computed Tomographic Angiography (CTA) is regarded as a
Purpose: To study the accuracy of motion information extracted from beat-to-beat 3D image-based navigators (3D iNAVs) collected using a variable-density cones trajectory with different combinations of spatial resolutions and scan acceleration factors
Purpose: To develop a respiratory-resolved motion-compensation method for free-breathing, high-resolution coronary magnetic resonance angiography using a 3D cones trajectory. Methods: To achieve respiratory-resolved 0.98 mm resolution images in a c