ترغب بنشر مسار تعليمي؟ اضغط هنا

A direct comparison of high-speed methods for the numerical Abel transform

53   0   0.0 ( 0 )
 نشر من قبل Daniel Hickstein
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Abel transform is a mathematical operation that transforms a cylindrically symmetric three-dimensional (3D) object into its two-dimensional (2D) projection. The inverse Abel transform reconstructs the 3D object from the 2D projection. Abel transforms have wide application across numerous fields of science, especially chemical physics, astronomy, and the study of laser-plasma plumes. Consequently, many numerical methods for the Abel transform have been developed, which makes it challenging to select the ideal method for a specific application. In this work eight transform methods have been incorporated into a single, open-source Python software package (PyAbel) to provide a direct comparison of the capabilities, advantages, and relative computational efficiency of each transform method. Most of the tested methods provide similar, high-quality results. However, the computational efficiency varies across several orders of magnitude. By optimizing the algorithms, we find that some transform methods are sufficiently fast to transform 1-megapixel images at more than 100 frames per second on a desktop personal computer. In addition, we demonstrate the transform of gigapixel images.



قيم البحث

اقرأ أيضاً

Superconducting microresonators have been successfully utilized as detection elements for a wide variety of applications. With multiplexing factors exceeding 1,000 detectors per transmission line, they are the most scalable low-temperature detector t echnology demonstrated to date. For high-throughput applications, fewer detectors can be coupled to a single wire but utilize a larger per-detector bandwidth. For all existing designs, fluctuations in fabrication tolerances result in a non-uniform shift in resonance frequency and sensitivity, which ultimately limits the efficiency of band-width utilization. Here we present the design, implementation, and initial characterization of a superconducting microresonator readout integrating two tunable inductances per detector. We demonstrate that these tuning elements provide independent control of both the detector frequency and sensitivity, allowing us to maximize the transmission line bandwidth utilization. Finally we discuss the integration of these detectors in a multilayer fabrication stack for high-speed readout of the D-Wave quantum processor, highlighting the use of control and routing circuitry composed of single flux-quantum loops to minimize the number of control wires at the lowest temperature stage.
329 - Eliyahu Osherovich 2012
In this work we consider the problem of reconstruction of a signal from the magnitude of its Fourier transform, also known as phase retrieval. The problem arises in many areas of astronomy, crystallography, optics, and coherent diffraction imaging (C DI). Our main goal is to develop an efficient reconstruction method based on continuous optimization techniques. Unlike current reconstruction methods, which are based on alternating projections, our approach leads to a much faster and more robust method. However, all previous attempts to employ continuous optimization methods, such as Newton-type algorithms, to the phase retrieval problem failed. In this work we provide an explanation for this failure, and based on this explanation we devise a sufficient condition that allows development of new reconstruction methods---approximately known Fourier phase. We demonstrate that a rough (up to $pi/2$ radians) Fourier phase estimate practically guarantees successful reconstruction by any reasonable method. We also present a new reconstruction method whose reconstruction time is orders of magnitude faster than that of the current method-of-choice in phase retrieval---Hybrid Input-Output (HIO). Moreover, our method is capable of successful reconstruction even in the situations where HIO is known to fail. We also extended our method to other applications: Fourier domain holography, and interferometry. Additionally we developed a new sparsity-based method for sub-wavelength CDI. Using this method we demonstrated experimental resolution exceeding several times the physical limit imposed by the diffraction light properties (so called diffraction limit).
A search for dark matter using an underground single-phase liquid xenon detector was conducted at the Kamioka Observatory in Japan, particularly for Weakly Interacting Massive Particles (WIMPs). We have used 705.9 live days of data in a fiducial volu me containing 97 kg of liquid xenon at the center of the detector. The event rate in the fiducial volume after the data reduction was ${rm (4.2 pm 0.2) times 10^{-3} , day^{-1}kg^{-1} keV_{ee}^{-1}}$ at ${rm 5 , keV_{ee}}$, with a signal efficiency of ${rm 20%}$. All the remaining events are consistent with our background evaluation, mostly of the mis-reconstructed events originated from $^{210}$Pb in the copper plates lining the detectors inner surface. The obtained upper limit on a spin-independent WIMP-nucleon cross section was ${rm 2.2 times 10^{-44} , cm^{2}}$ for a WIMP mass of ${rm 60 , GeV/c^{2}}$ at the $90%$ confidence level, which was the most stringent limit among results from single-phase liquid xenon detectors.
126 - J. Dudouet 2013
During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and th e surrounding healthy tissues, the accuracy must be higher than ($pm$3% and$pm$1 mm). Therefore, measurements are performed to determine the double differential cross section for different reactions. In this paper, the analysis of data from 12C +12C reactions at 95 MeV/u are presented. The emitted particles are detected with DeltaEthin-DeltaEthick-E telescopes made of a stack of two silicon detectors and a CsI crystal. Two different methods are used to identify the particles. One is based on graphical cuts onto the DeltaE-E maps, the second is based on the so-called KaliVeda method using a functional description of DeltaE versus E. The results of the two methods will be presented in this paper as well as the comparison between both.
Rapidly rotating neutron stars are promising sources of continuous gravitational wave radiation for the LIGO and Virgo interferometers. The majority of neutron stars in our galaxy have not been identified with electromagnetic observations. All-sky se arches for isolated neutron stars offer the potential to detect gravitational waves from these unidentified sources. The parameter space of these blind all-sky searches, which also cover a large range of frequencies and frequency derivatives, presents a significant computational challenge. Different methods have been designed to perform these searches within acceptable computational limits. Here we describe the first benchmark in a project to compare the search methods currently available for the detection of unknown isolated neutron stars. We employ a mock data challenge to compare the ability of each search method to recover signals simulated assuming a standard signal model. We find similar performance among the short duration search methods, while the long duration search method achieves up to a factor of two higher sensitivity. We find the absence of second derivative frequency in the search parameter space does not degrade search sensivity for signals with physically plausible second derivative frequencies. We also report on the parameter estimation accuracy of each search method, and the stability of the sensitivity in frequency, frequency derivative and in the presence of detector noise.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا